■ DRM (Digital input)

Function Port

Specifications

1. Click [On] to turn on the function.

  

2. Click [SET]

3. Follow below table to set the specific power limit value, you can check the percentage
    by DRM(%) on the APP. 

■ PARTIAL/ZERO EXPORT

The function has to be used with current sensor (optional part).
1. Click [On] to turn on the power meter function.
2. Click [On] to turn on the partial/zero export function.
3. Set the Rate% base on power company or local regulation.
4. Set the Sign capacity & PV capacity, the inverter will use the lower value as the power
    limit reference, and then click [SET].

■ DRY CONTACT

1. The types of alert are “On grid, Insulation, Alarm, Error and Fault”, select to trigger.
2. Click [SET]
3. When the Inverter triggers the selected alarm, the inverter will close dry contact relay 
    to trigger external device.

Digital input

Power meter

Dry contact

* Screw torque required for

  assembling: 8±2 kgf-cm

Short pins

Inverter behavior (AU)

D6 & D2

D6 & D1

D6 & D3

D6 & D4

D6 & D5

DRM 7 - Power de-rating to 75%

DRM 5 - Power de-rating to 0%

DRM 6 - Power de-rating to 50%

DRM 8 - Power de-rating to 100%

DRM 0 - Disconnect from grid

D1

D2

D3

D4

D5

D6

Dry

contact

Dry

contact

Power

meter

Power

meter

■ DRM (Digital input)

■ PARTIAL/ZERO EXPORT

■ DRY CONTACT

Enclosure

Operating temperature

Relative humidity

Galvanic isolation

Safety class

Overvoltage category

Flicker impedance

Three-phase combinations

Max. input voltage

Operating voltage range

MPP range (rated power)

Normal voltage

MPP tracker

Startup voltage

Input connection

Max. inverter backfeed

current to the array

Maximum input current

Max. short circuit current (per MPPT)

Operating Altitude

Environmental category

Pollution degree

Nominal output power

 

1

Maximum power

Nominal output current

Maximum output fault current

Maximum output over current protection

Frequency

Total harmonic distortion

 

2

Power factor

 

2

Peak efficiency

EU efficiency

Output connection

Voltage

Max. output current

Current (inrush)
(A, peak and duration)

Housing

Cooling

IP rating

External communication

Weight

Dimensions

GENERAL

DC INPUT (Solar side)

AC OUTPUT (Grid side)

MECHANISM

Powder-coated aluminium

-25~60°C, full power up to 40°C

2000 m

0% – 95% non-condensing.

Outdoor, wet locations

No (TL Topology)

Class I metal enclosure with protective earth

Internal: II, External: III

AC output: III, DC input: II

Z = 0.4 + j 0.25 Ω (total impedance)

No

600 Vdc

350 Vdc

30-550 Vdc

240-500 Vdc

11 Adc for each / 22 Adc for total

2

15 A

0 A

35 Vdc

H4, 2 pairs

230Vac -20%~+22%

30 A peak, 1 ms

50/60 Hz

<3% @Rated power

>0.99 @Rated power

97.5%

96.8%

IP 67 single-phase

5000 VA

5000 VA

25 A

25 A

22 A

23 A

Die casting

Convection cooling

IP65

Wi-Fi

12 kg

380 × 318 × 130 mm

1: (a) 4.99kVA max. for Australia (AU / NZ)

    (b) 4.6kVA max. for Germany (DE)
2: reactive power control disabled
3: not support AS4777.2:2015 Single-phase inverters used in three-phase combinations

4: Information of regulations and directives please refer to user manual.

1. Follow the APP guideline to create an account and connect to the inverter.

Starting up the inverter function

5. Enter password (please contact us)

2. Click 

3. Click “SETTING” 

4. Click “Other”

2

1

1

1

1

3

4

2

4

2

2