background image

 

DELTA - Venlighedsvej 4 - 2970 Hørsholm - Denmark - Tel. +45 72 19 40 00 - [email protected] 

 

 

 

 

GRX Online Retroreflectivity Sensor 

User Manual 

 

 Online sensor for production line control of the retroreflection properties of traffic sign sheeting materials. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manual August 2018 ver. 1.2 - English 

 

 

Содержание GRX

Страница 1: ...nmark Tel 45 72 19 40 00 roadsensors delta dk GRX Online Retroreflectivity Sensor User Manual Online sensor for production line control of the retroreflection properties of traffic sign sheeting materials Manual August 2018 ver 1 2 English ...

Страница 2: ...ORS CONTAINED HEREIN OR FOR INCI DENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING PERFORMANCE OR USE OF THIS MATERIAL Intended use purpose GRX Online is an industrial online sensor for quality control of retroreflective sheeting materials on indoor production line Important Safety and Handling Information Caution Changes modifications not approved by the DELTA could void the user ...

Страница 3: ...is in conformity with the essential requirements and other relevant requirements of ICES 003 2016 The product is verified according to ICES 003 2016 Class B The equipment is accredited safety test with the internationally harmonized safety standard IEC 60950 1 2005 Second Edition Am 1 2009 Am 2 2013 Supplementary information Technical file held by the undersigned Place and date of issue of this SD...

Страница 4: ...evant requirements of the Electromagnetic Compatibility EMC Directive 2014 30 EU EN 61326 1 2013 Industrial level Class A EN 61000 3 2 2014 EN 61000 3 3 2013 Low Voltage LVD Directive 2014 35 EU EN 61010 1 2010 IEC 61010 1 2010 AMD 2016 EN 62471 2008 Restriction of the use of certain hazardous substances RoHS directive 2011 65 EU Assessment of components datasheets Supplementary information Techni...

Страница 5: ... issue of this AoC Hørsholm 10 July 2018 Signed by or for the manufacturer Signature of authorized person Name in print Susan Bonde QA Manager Product Division Electronics Microelectronics Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmfu...

Страница 6: ...nnecting the sensor 8 Mounting the sensor in the production line 8 Software installation 9 Program location 9 Connecting to the sensor to the PC 9 General 9 Configuring the network adapter 10 Calibration procedure 11 Start stop measuring 12 Start stop logging 12 Appendix A Specifications 14 Optical characteristics 14 Standards 14 Electrical characteristics 14 Environmental characteristics 14 Mecha...

Страница 7: ...rnational CEN and ASTM standards The instrument complies with the following European and US standards EN 12899 Fixed Vertical Road Traffic Signs part 1 5 Part 1 Fixed Signs Part 4 Factory Production Control EN 20471 High Visibility Clothing Test Methods and Requirements ASTM E 1709 Standard Test Method for Measurement of Retroreflective Signs Using a Portable Retroreflectometer at a 0 2 degree Obs...

Страница 8: ...nsor o 1 pcs Power over ethernet injector o 1 pcs USB memory stick with PC control software and user guide Connecting the sensor The online sensor is powered through the ethernet cable Connect the sensor unit to the POE injectors OUT socket Connect the POE injector IN socket to the PC Connect the POE injector power cable to an electrical outlet Ethernet cables must be CAT5 or better GRX ONLINE SEN...

Страница 9: ...TA Furthermore a short cut is placed on the Windows desktop Connecting to the sensor to the PC General The sensor communicates over ethernet The computer running the control software must be configured to access the sensor The sensor is configured with a fixed IP address on the private subnet 10 201 201 0 Sensor IP address fixed 10 201 201 5 The control computer should be configured with a fixed I...

Страница 10: ...rk adapter Open the Control Panel and start Network and Sharing center then select Change adapter settings and then select Properties Select Internet Protocol Version 4 TCP IPv4 and click Properties Select Use the following IP address Enter IP address 10 201 201 2 Enter subnet mask 255 255 255 0 Click OK and Close ...

Страница 11: ...uring distance Place the calibration target in the same distance as the sheeting Start streaming to help position the calibration target The illuminated circle should be in the center of the calibration target Stop streaming when the target is positioned correctly Click Calibrate and enter the calibration values for each observation angle Enter the calibration values in the calibration window Clic...

Страница 12: ...uring times result in lower precision i e greater variations in the measurement results When the sensor is measuring the green LED on the rear cover plate will be flashing quickly 10 Hz The measurement grid scrolls automatically when a measurement is received The grid can hold a maxi mum of 50 000 measurements When the limit is reached the oldest measurements are removed from the grid Start stop l...

Страница 13: ...Technology May 2018 The log file is in TAB delimited ASCII format Example Number Timestamp Ra02 Ra033 Ra05 Ra07 Ra10 Ra15 Ra20 8 2016 11 01 12 54 05 391 276 203 106 35 17 13 6 9 2016 11 01 12 54 05 890 276 203 106 35 17 13 6 10 2016 11 01 12 54 06 390 276 203 106 35 17 13 6 ...

Страница 14: ...ular aperture 0 1 Receptor angular aperture 0 1 Light source Illuminant A Receptor sensitivity Eye corrected Standards ASTM E1709 E2540 DIN 67520 EN12899 1 FCC FCC part 15 Subpart B Class A Electrical safety IEC 61010 1 Electrical characteristics Measurement time variable 0 2 2 seconds 5Hz 0 5 Hz Power POE Power Over Ethernet Power consumption 10W Data connection Ethernet 10 100 Environmental char...

Страница 15: ...GRX Online Retroreflectivity Sensor User Manual 15 DELTA a part of FORCE Technology May 2018 Mechanical drawing ...