Delta GBR80MHLED Скачать руководство пользователя страница 3

MODELS: GBR80HLED, GBR80LED, GBR80MHLED, GBR100HLED, GBR100LED

 

 

DUCT CONNECTION

 

1.

 

Insert the duct into the duct connector and tape all ductwork 
connections to make them secure and air tight.

 

2.

 

Install the duct with a gradient 1°~2° to the outside.

 

Inside

Outside

Duct

Body

Gradient

1°~2°

Tape

Ceiling

Grille

Duct Connector

 

CONNECT WIRING

 

1.

 

Follow all local electrical and safety codes, ANSI/NFPA70. 

2.

 

NEVER place a switch where it can be reached from a tub or 
shower.

 

3.

 

Connect wires as shown in wiring diagrams.

 

For Models: GBR80LED, GBR80MHLED, GBR100LED 

POWER SWITCH

LIGHT SWITCH

JUNCTION BOX

SWITCH BOX

WHITE

BLACK

OFF

ON

WHITE

RED

GREEN

GRD

L

N

L

N

OFF

ON

 

ON/OFF SWITCH

(purchase separately)

SWITCH BOX

120 VAC

LINE IN

WIRING

PLATE

BLACK
WHITE

GROUND

(bare)

RED

LIGHT

SWITCH

POWER
SWITCH

 

For

 Models: GBR80HLED, GBR100HLED 

HI

POWER SWITCH

MODE SWITCH

JUNCTION BOX

SWITCH BOX

WHITE

BLACK

OFF

ON

BLUE

GREEN

GRD

L

N

L

N

ON

LIGHT SWITCH

RED

L

N

WHITE

WHITE

 

BLACK

ON/OFF SWITCH

(purchase separately)

SWITCH BOX

120 VAC

LINE IN

WHITE

GROUND

(bare)

POWER
SWITCH

WIRING

PLATE

MODE

SWITCH

LIGHT

SWITCH

RED

  BLUE

 

4.

 

Using wire nuts (not provided), connect house power cable 
to ventilating fan.

 

 

5.

 

14 AWG (2.1 mm

2

) is the smallest conductor that shall be 

used for branch-circuit wiring. 

GRILLE ATTACHMENT & TEST RUN

 

 

1.

 

Insert the LED lighting connector into the power socket of 
main body as below shown. 

2.

 

Insert the motion plug connector into the housing. (for 
GBR80MHLED only)

 

 

3.

 

Insert the mounting springs into the slots and mount the 
grille to the fan unit. 

Spring

Grille

Lighting Connector

Slots

 

4.

 

When the power on, check for abnormal vibration or sound. 

OPERATION

 

1.

 

For Single Speed Models: GBR80LED, GBR100LED 

1-1.

 

Turn on the power switch to operate ON or OFF, and LED 
indicator is green. 

2.

 

For Humidity models: 

GBR80HLED, GBR80MHLED, GBR100HLED 

Humidity tolerance is about ±10%. Long -time operation will 
influence the detecting precision as dust accumulates. The 
humidity switch may need to be adjusted. 

80 SERIES

05

0

CFM

50

8

0

7

0

60

%RH

06

0

50

8

0

7

0

60

%RH

100 SERIES

Low speed air volume

preset control

Humidity preset control

Low Speed

CFM

Low Speed

 

2-1.

 

Humidity control mode: Turn the POWER switch on to 
operate at humidity control mode - the LED indicator 
will be blue. When the ambient humidity is higher than 
the user-adjustable set-point, the fan will run at full 
speed. When the ambient humidity is lower than the 
set-point, the fan will continue to run at the full speed 
until a 10-minute time delay has elapsed, and then will 
automatically change to the user -adjustable low speed 
airflow. 

Page 3. 

 