background image

MODELS: GBR80HLED, GBR80LED, GBR80MHLED, GBR100HLED, GBR100LED

 

 

 

 

INSTALLATION AND OPERATING INSTRUCTIONS

 

VENTILATION FAN /DIMMABLE LED LIGHT

 

READ AND SAVE THESE INSTRUCTIONS 
GENERAL SAFETY INFORMATION

 

1.

 

Make sure that the electric service supply voltage is AC 120V, 
60Hz.

 

2.

 

Follow all local electrical and safety codes, as well as the Nation 
Electrical Code (NEC) and the Occupation Safety and Healthy Act 
(OSH Act).

 

3.

 

Always disconnect the power source before working on or near 
the ventilating fan, motor or junction box.

 

4.

 

Protect the power cord from sharp edges, oil, grease, hot 
surfaces, chemicals or other objects.

 

5.

 

Do not kink the power cord.

 

6.

 

Do not install the unit where ducts are configured as shown in 
Fig. A.

 

7.

 

Provide suction parts with proper ventilation.

 

8.

 

This unit is UL listed for use over a bathtub or shower when 
installed in a GFCI protected branch circuit.

 

WARNING

 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 
INJURY TO PERSONS, OBSERVE THE FOLLOWING:

 

1.

 

Use this unit only in the manner intended by the manufacturer. 
If you have questions, contact the manufacturer.

 

2.

 

Before servicing or cleaning unit, switch power off at service 
panel and lock the service disconnecting means to prevent 
power from being switched on accidentally. When the service 
disconnecting means cannot be locked, securely fasten a 
prominent warning device, such as a tag, to the service panel.

 

3.

 

Installation work and electrical wiring must be done by qualified 
person(s) in accordance with all applicable codes and standards, 
including fire-rated construction.

 

4.

 

Sufficient air is needed for proper combustion and exhausting of 
gases through the flue (chimney) of fuel burning equipment to 
prevent back drafting. Follow the heating equipment 
manufacturer’s guideline and safety standards such as those 
published by the National Fire Protection Association (NFPA), 
and the American Society of Heating, Refrigerating and Air-
Conditioning Engineers (ASHRAE), and the local code authorities.

 

5.

 

When cutting or drilling into wall or ceiling, do not damage 
electrical wiring and other hidden utilities.

 

6.

 

Ducted fans must always be vented to the outdoors.

 

7.

 

If this unit is to be installed over a tub or shower, it must be 
marked as appropriate for the application and be connected to a 
GFCI (Ground Fault Circuit Interrupter) --- protected branch 
circuit.

 

8.

 

Do not use this unit with any other solid-state control devices. 
Solid-state control devices may cause harmonic distortion, 
which can cause a motor humming noise. (Avertissement: ne 
convient pas à des régulateurs de vitesse à semi-conducteurs).

 

9.

 

NEVER place a switch where it can be reached from a tub or 
shower.

 

10.

 

Not to be installed in a ceiling thermally insulated to a value 
greater than R50. (This is required for installation in Canada 
only). 

Turning angle too large

Duct shrink

Too many elbows

Elbow near the body

Body

 

Fig. A

 

CAUTION

 

1.

 

For General Ventilating Use Only. Do Not Use To Exhaust 
Hazardous Or Explosive Materials And Vapors.

 

2.

 

Not for use in cooking areas. (Fig. B)

 

3.

 

This product must properly connect to the grounding conductor 
of the supply circuit.

 

4. 

 To reduce the risk of injury to persons, install the fan at least 8.2 
feet (2.5m) above the floor.

 

45

Cooking area

45

Do not install above or

  inside this area

 Cooking

Equipment

floor

 

Fig. B

 

Page 1. 

 

Отзывы: