1. Manual Defrost/Stop Defrost

Hold  and 

for 5 seconds.

2. Panel Parameter Lock

Hold   and 

SET

 for 3 seconds. DIsplay “00” for lock status and “33” for 

unlock status. When locked, only setpoint is able for setting.

3. Evaporator temperature

Hold   for one second to display. It will switch back to indoor tempera-

ture after 3 seconds. The rest parameter setting cannot be changed.

4. Parameter Value Increase

Value increase with   button pressed.

5. Default Setting Restore:

Unplug the power line, hole   and 

SET

 then plug in to display rS.

1. Panel Parameter Lock

Hold   and 

SET

 for 3 seconds. DIsplay “00” for lock status and 

“33” for unlock status.  

When locked, only setpoint is able for setting.

2. User’s Parameter Option

Hold 

SET

 for 3 seconds to enter parameter setting. “Temp. Set” 

is ON. Press 

SET

 for one second, the parameter can be adjusted 

accordingly. 

3.Release Quick Setting Mode

In quick setting mode, press 

SET

 or any other button.

4. Default Setting Restore:

Unplug the power line, hole   and 

SET

 

then plug in to 

display rS.

1. Manual Defrost/Stop Defrost

Hold  and 

for 5 seconds.

2. Quick Setting

Press 

for one second, then press  or 

 to adjust setpoint. 

If no action occurs within 5 seconds, or press 

SET

 directly to restore 

parameter automatically, and indoor temperature displayed. 

Up: ON

Down: OFF

Up: ON

Down: OFF

RS-617S

Button Instruction

Wiring Instruction

G

G

G

G

P11

P12

AC1

AC1

AC1

AC1

P13

FAN

COMP

DEFROST

LIGHT

DEFOG

RLY5

FAN

RLY4

1.5HP/240VAC

1HP/120VAC

DEFROST

COMP

10A

Compr
essor pr

otection contact

P7

2A

1

2

AC2

P5

NEB

1 3W

AC110V

-220V

User’s wiring

10A

10A

P2

AC2

P9

P1

P1: Connect with operation panel. 

Power supply: AC 110V-220V ± 10% single 

phase 50/60Hz

Power consumption: Max. 10 Watt 

(Controller only)

Reading range: —45°C - 45°C ± 1°C

The output contact capacity show in the 

wiring diagram. Do not overload.

If the compressor uses 220V, but the other 

devices are 110V, connect their common 

line to #G instead of #AC1

 Before applying power to the unit, 

always check if the voltage set correctly 

according to the input voltage.