2019/01/22 

 

Series Temperature Controller Instruction Sheet 

Thank you very much for choosing Delta DTE series temperature controller. Please read this instruction sheet carefully before using your 
DTE to ensure proper operation. Keep this instruction sheet handy for quick reference. 

 Warning 

 

DANGER! CAUTION! ELECTRIC SHOCK! 

 

DTE is an OPEN-TYPE device and therefore should be installed in an enclosure free of airborne dust, humidity, electric shock 
and vibration. The enclosure should prevent non-maintenance staff from operating the device (e.g. key or specific tools are 
required for opening the enclosure) in case danger and damage on the device may occur

1.  Prevent dust or metallic debris from falling into the device and cause malfunctions. 

DO NOT

 modify or uninstall the circuit board of DTE 

without being permitted. 

DO NOT

 use empty terminals. 

2.  Keep away from high-voltage and high-frequency environment during the installation in case of interference. Prevent using the device in 

premises which contain:   
(a) dust or corrosive gas;    (b) high humidity and high radiation;    (c) shock and vibration. 

3.  The power has to be switched off when wiring or changing the temperature sensor. 
4.  When installing the circuit board of the accessory, please make sure the power of the main unit is switched off and insert the accessory 

into the correct slot on the main unit. 

5.  Make sure to use compensation wire which matches the thermocouple or platinum resistance when extending or connecting the 

thermocouple or platinum resistance. 

6.  Keep the wire as short as possible when wiring a sensor to the controller. Separate the power cable and load wire in order to prevent 

interference and induced noise. 

7.  Make sure the power cables and signal device are installed correctly before switching on the power; otherwise serious damage may 

occur. 

8. 

DO NOT

 touch the terminal or repair the device when the power is on; otherwise an electric shock may occur.   

9.  Please wait for 1 minute after the power is switched off to allow the capacitor to discharge and 

DO NOT

 touch the internal wiring within 

this period.   

10. 

DO NOT

 touch the internal terminal when DTE is either switched on or off in case you may damage the circuit. 

11. Please place DTE with other heating objects (e.g. power supply) within proper distance while installing DTE. 

 

Ordering Information

 

 

Series name 

DTE: Delta E series temperature controller 

  1   

Device type 

1: main unit 

2: accessory 

  2      3

    -   

 

0T: 4-channel TC 
0P: 3-channel PT 

0T: 4 - channel TC 
0P: 3 - channel PT 
0V: 4 channels of voltage pulse output 
0C: 4 channels of linear current output 
0R: 4 channels of relay output 
0L: 4 channels of linear voltage output 

DS: Display and setup module 
CT: 4 channels of current transformer sensors 
0D: 8-channel EVENT input 

 Functions & Electrical Specifications

 

Power input 

24 VDC, isolated switching power supply 

Voltage range 

90 to 110% rated voltage 

Power consumption 

Max. 10 W + 3 W × number of DTC2000 controllers connected in parallel (Max. 7) 

Input sensor 

Thermocouple: K, J, T, E, N, R, S, B, L, U, TXK 
Platinum resistance: Pt100, JPt100, Cu50, Ni120 

Sampling cycle 

Thermocouple or platinum resistance: 1.0 second/all input 

Control method 

PID, PID programmable, manual, ON/OFF 

Output accessories 
(optional) 

Relay output: SPST, Max. 250 VAC load, 3A resistive load 
Voltage pulse output: 12 VDC, Max. 40 mA current output 
Current output: DC 4 to 20 mA output (resistive load < 500 Ω); for OUT1 and OUT2 only 

Содержание DTE10P Series

Страница 1: ...Separate the power cable and load wire in order to prevent interference and induced noise 7 Make sure the power cables and signal device are installed correctly before switching on the power otherwis...

Страница 2: ...dbus ASCII RTU Extension port The extension port transmits 24 V power supply and communication signals to extension module DTC2000 Vibration resistance 10 to 55 Hz 10m s2 3 axes 10mins Shock resistanc...

Страница 3: ...hannels of input Every channel corresponds to 2 groups of output and 2 groups of alarms OUT1 and SUB1 are for control output and OUT1 can be used for proportional output OUT2 and SUB2 are fixed for al...

Страница 4: ...ed when the PV exceeds AL H or falls below AL L ON OFF AL L AL H 6 Alarm output will be enabled when the temperature reaches the absolute value of the upper limit The alarm will be enabled when the PV...

Страница 5: ...e channel CH8 CH7 CH6 CH5 CH4 CH3 CH2 CH1 CT and adjustment Current Transformer Function DTE10T offers maximum 4 channels of CT CT1 CT4 responsible for monitoring the current in INA Each CT group can...

Страница 6: ...A5H 19A6H 19A7H CT adjustment value 19A8H 19A9H 19AAH 19ABH 3 OUT1 control mode has to be set to 0 heating or 1 cooling It cannot be set to 2 proportional output 4 You can select Alarm 1 or Alarm 2 to...

Страница 7: ...d then 0020H into address 4824H Bits in 4824H Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 Flag Hot runner control Slop control Latch CT EVENT Notes The flag to enable slope function is at bit5 of 4824H Wr...

Страница 8: ...Set up the time using the table below Unit second CH CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 Address for delayed alarm 1990H 1991H 1992H 1993H 1994H 1995H 1996H 1997H Output Limits Function The output is lim...

Страница 9: ...The flag to enable hot runner control is at bit6 of 4824H and bit5 as to be enabled at the same time Write 0060H to set both bits on If there is already a set value in 4824H and you would like to mod...

Страница 10: ...609 H104E H1709 H104F H1809 Proportional band coefficient of output 1 and output 2 0 01 99 99 Unit 0 01 H1050 H110A H1051 H120A H1052 H130A H1053 H140A H1054 H150A H1055 H160A H1056 H170A H1057 H180A...

Страница 11: ...eserved H10F5 Reserved H10F6 Channel disable H10F7 Filter times Communication specifications See Table 4 H10F8 Auto ID setup H10F9 Filter range H10FA Baud rate H10FB ASCII 0 RTU 1 H10FC 8 bits 0 7 bit...

Страница 12: ...0 Unit 1 min 4 Communication format H03 read bit data H06 write bit data ASCII Mode Single read and write Read Command Read Response Message Write Command Write Response Message Start word Start word...

Страница 13: ...H03 Command H06 Command H06 Read start address of data H10 Length of response data byte H04 Write data address H10 Write data address H10 H00 H01 H01 Read length of data bit word H00 Data content 1 H...

Страница 14: ...ngth reg_crc RTUData i i for j 0 j 8 j if reg_crc 0x01 reg_crc reg_crc 1 0xA001 else reg_crc reg_crc 1 return reg_crc Software for Setting up Communication on PC Download the free software on Delta s...

Отзывы: