(6) Hardware specifications

 

Model 

DOP-105CQ 

Display 

Panel type 

5.6" TFT LCD (65536 colors) 

Resolution 

320 x 234 pixels 

Backlight 

LED backlight

   

(half-life under room temperature 25°C > 20,000 hours)

*1

 

Display 

range 

113.28 x 84.70 mm 

Brightness 

200 cd/m² (Typ.) 

CPU 

ARM Cortex-A8 (800 MHz) 

Flash ROM 

256 Mbytes 

RAM 

256 Mbytes 

Touchscreen 

4-wire resistive touchscreen > 10,000,000 operated 

Buzzer 

Multi-tone frequency (2 - 4 kHz) / 80 dB 

Network interface 

N/A 

USB 

1 USB slave Ver 2.0; 1 USB host Ver 2.0 

SD 

N/A 

Serial 

communication 

port 

COM1 

RS-232 (supporting flow control) 

*2

 

COM2 

RS-232 / RS-485 

*2

 

COM3 

RS-422 / RS-485 

*2

 

Auxiliary function key 

N/A 

Calendar 

Built-in 

Cooling method 

Natural cooling 

Approvals 

CE / UL   

(please use shielding network cable and magnetic ring with the 

filter of 300 ohm / 100 MHz) 

Panel waterproof level 

IP65 / NEMA4 (indoor use only)

 

Operation voltage

*2

 

DC +24V (-15% to +15%)   

(please use an isolated power supply) 

(Supplied by Class 2 or SELV circuit (isolated from MAINS by double 

insulation))

 

Leakage current 

500 V

AC

 for 1 minute (between DC24V terminal and FG terminal) 

Power consumption

*3

 

6.86 W (Max) 

*3

 

Backup battery 

3V lithium battery CR2032 × 1 

Backup battery life 

About 3 years or more at 25°C (77°F) 

(subject to operation temperature and condition) 

Operation temperature 

0°C to 50°C (32°F to 122°F) 

Storage temperature 

-20°C to +60°C (-4°F to 140°F) 

Operating environment 

10% to 90% RH [0 to 40°C (32 to 104°F)], 

10% to 55% RH [41 to 50°C (105.8 to 122°F)]; 

pollution degree: 2 

Vibration resistance 

Conforms to IEC61131-2: continuous vibration 5 Hz - 8.3 Hz with 

amplitude 3.5 mm; 8.3 Hz - 150 Hz with amplitude 1G 

Shock resistance 

Conforms to IEC60068-2-27: 11 ms, 15 G Peak, in X, Y, Z 

directions each for 6 times 

Dimensions 

(W) x (H) x (D) mm 

184 x 144 x 50 

Mounting dimensions 

(W) x (H) mm 

172.4 x 132.4 

Weight 

Approx. 670 g 

Note: 
1.  The half-life of the backlight is defined as the maximum luminance being reduced by 50% when the 

maximum drive current is supplied to the HMI. The life of LED backlight shown here is estimated at 
the room temperature of 25°C (77°F) with ambient humidity. 

2.  The withstand voltage of the isolated power circuit is 1500 V peak for 1 minute. 
3.  The HMI power consumption is the power consumed when the HMI is not connecting with other 

peripheral devices. To ensure normal operation of the HMI, the recommended capacity of the power 
supply is 1.5 to 2 times of the specified power consumption. 

4.  Isolated power supply is recommended. 
5.  For the programming software DOPSoft of DOP-100 series and its user manual, you can download 

them at http://www.delta.com.tw/ia. 

6.  DOP-100 series can be used with other industrial automation equipment. Please read through this 

sheet carefully and install the product according to the instructions to avoid danger.

 

Содержание DOP-105CQ

Страница 1: ...ibutors or Delta Customer Service Center The instruction sheet may be revised without prior notice Contact our distributors or download the latest version from the Delta website http www deltaww com t...

Страница 2: ...C to 50 C 32 F to 122 F Storage temperature 20 C to 60 C 4 F to 140 F Operating environment 10 to 90 RH 0 to 40 C 32 to 104 F 10 to 55 RH 41 to 50 C 105 8 to 122 F pollution degree 2 Vibration resist...

Страница 3: ...k man n son versiyonunu internetten indirebilirsiniz http www delta com tw ia 2 Haberle me Pinleri DOP 105CQ COM1 port COM Port Pin MOD 1 RS 232 1 2 RXD 3 TXD 4 5 GND 6 7 RTS 8 CTS 9 DOP 105CQ COM2 po...

Страница 4: ...m pil CR2032 1 Yedekleme Pil mr Normal ko ullarda 25 o C de 3 y l veya daha fazla al ma S cakl 0 C 50 C 32 F 122 F Depolama S cakl 20 C 60 C 4 F 140 F al ma Ortam 10 90 RH 0 C 40 C 10 55 RH 41 C 50 C...

Страница 5: ...P 105CQ COM2 COM3 COM Port MODE1 MODE2 MODE3 COM2 COM3 COM2 COM3 COM2 COM3 RS 232 RS 485 RS 485 RS 485 RS 232 RS 422 1 D TXD 2 RXD RXD 3 TXD TXD 4 D D RXD 5 GND GND GND 6 D TXD 7 8 9 D D RXD 3 DOP 105...

Страница 6: ...5 2 N A CE UL shielding 300 ohm 100 MHz IP65 NEMA4 2 DC 24V 15 15 Supplied by Class 2 or SELV circuit isolated from MAINS by double insulation DC24V FG AC500V 1 3 6 86 W Max 3 3V CR2032 1 25 C 77 F 0...

Страница 7: ...COM Port MODE1 MODE2 MODE3 COM2 COM3 COM2 COM3 COM2 COM3 RS 232 RS 485 RS 485 RS 485 RS 232 RS 422 1 D TXD 2 RXD RXD 3 TXD TXD 4 D D RXD 5 GND GND GND 6 D TXD 7 8 9 D D RXD 3 DOP 105CQ A DOP 105CQ A C...

Страница 8: ...z 8 3Hz 3 5mm 8 3Hz 150Hz 1G IEC60068 2 27 11ms 15G Peak X Y Z 6 W x H x D mm 184 x 144 x 50 W x H mm 172 4 x 132 4 670g 1 25 o C 77 F 2 1 1500 V 3 1 5 2 4 5 DOP 100 DOPSoft http www delta com tw ia 6...

Отзывы: