background image

TECHNICAL DATASHEET

 

CliQ DIN Rail Power Supply 

24V 60W 1 Phase / DRP024V060W1AA

 

 

 

  

All parameters are specified at 25°C ambient and AC input unless otherwise indicated.

 

  www.DeltaPSU.com (November 2020, Rev. 08)  

 

1

 

  

Highlights & Features 

  Universal AC input voltage range 

  Power will not de-rate for the entire input voltage range 

  Power Boost of 150% for 3 seconds 

  Full corrosion resistant aluminium casing 

  SEMI F47 certified 

  Conforms to harmonic current IEC/EN 61000-3-2, Class A 

  Conformal coating on PCBAs to protect against common 

dust and chemical pollutants 

  Hazardous Locations approval to ATEX and Class I, Div 2 

  Certified according to IEC/EN/UL 62368-1 

 

 

Safety Standards 

 

CB Certified for worldwide use 

 

 

Model Number:

   

DRP024V060W1AA 

Unit Weight:

 

 

0.37 kg (0.82 lb) 

Dimensions (L x W x D):

  121 x 32 x 120

 

mm 

   

 

 

(4.76 x 1.26 x 4.72 inch)

 

 

 

General Description 

The DRP024V060W1AA is part of the CliQ DIN rail power supply series from one of the world’s leading power supply companies, Delta 

Electronics Group. The rugged metal has a compact body at only 32mm, which is both shock and vibration resistant according to 

IEC 60068-2 standard. The product operates within a wide temperature range from -20°C to +80°C. The DRP024V060W1AA features 

universal AC input voltage range from 85Vac to 264Vac and the power will not de-rate for the entire input voltage range. The single phase 

power supply unit includes overvoltage, overcurrent, over temperature and short circuit protections. The product features built-in Power 

Boost of 150% for 3 seconds. Such feature enables reserve power to be always available for reliable startup of loads with high inrush 

current, thus eliminating the need of a more expensive power supply unit at higher power rating. Another great feature is the conformal 

coating on the PCBA which allows DRP024V060W1AA to be certified to ATEX and Class I, Div 2 for use in hazardous locations. 

 

 

Model Information 

CliQ DIN Rail Power Supply 

 

Model  Number

 

Input Voltage Range

 

Rated Output  Voltage

 

Rated Output  Current

 

DRP024V060W1AA

 

85-264Vac (120-375Vdc) 

24Vdc 

2.50A 

 

 

Model Numbering 

DR

 

P

 

024V

 

060W

 

1

 

A

 

A

 

DIN Rail 

Power Supply 

Output Voltage  Output Power 

Single Phase 

CliQ Series 

Metal Case 
 

 

 

 

Содержание CliQ DRP024V060W1AA

Страница 1: ...The rugged metal has a compact body at only 32mm which is both shock and vibration resistant according to IEC 60068 2 standard The product operates within a wide temperature range from 20 C to 80 C Th...

Страница 2: ...al Output Voltage 24Vdc Factory Set Point Tolerance 24Vdc 2 Output Voltage Adjustment Range 22 28Vdc Output Current 2 50A continuously operating at 24 3 75A Power Boost for 3 seconds at 24V refer to t...

Страница 3: ...power by 2 5 C Horizontal Mounting 0 C de rate power by 1 C 50 C de rate power by 2 5 C 70 C de rate power by 4 C Operating Humidity 5 to 95 RH Non Condensing Operating Altitude 0 to 2 000 Meters 6 56...

Страница 4: ...E191395 UL 62368 1 and CSA C22 2 No 62368 1 File No E191395 CSA CSA C22 2 No 60950 1 and UL 60950 1 File No 181564 CB Scheme IEC 60950 1 IEC 62368 1 Industrial Control Equipment UL cUL listed UL 508 a...

Страница 5: ...st IEC 61000 4 4 Level 3 Criteria A1 2kV Surge IEC 61000 4 5 Level 3 Criteria A1 Common Mode2 2kV Differential Mode3 2kV Conducted IEC 61000 4 6 Level 3 Criteria A1 150kHz 80MHz 10Vrms Power Frequency...

Страница 6: ...cified at 25 C ambient and AC input unless otherwise indicated www DeltaPSU com November 2020 Rev 08 6 Block Diagram Device Description 1 Input terminal block connector 2 Output terminal block connect...

Страница 7: ...mperature Protection When activated the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep th...

Страница 8: ...les Use appropriate copper cables designed to sustain operating temperature of at least 75 C or more to fulfill UL requirements For stranded wires it is recommended to use suitable lug to crimp wires...

Страница 9: ...the device as well as a lateral distance of 50mm 1 97 inch to other units Note that the enclosure of the device can become very hot depending on the surrounding air temperature and load of the power...

Страница 10: ...0 of its final steady state set value Hold up Time Time between the collapse of the AC input voltage and the output falling to 95 of its steady state set value Inrush Current Inrush current is the pea...

Страница 11: ...ed and approved on 20A UL and 16A IEC branch circuits without additional protection device An external protection device is only required if the supplying branch has an ampacity greater than above Thu...

Страница 12: ...rrent will operate in Hiccup mode as shown in the illustration in the OLP OCP section on this page The power supply will return to normal operation after the short circuit is removed Overvoltage Prote...

Страница 13: ...em load from Vout Please note that output voltage Vout from DRR module will be VO output voltage of power supply Vdrop in DRR module Vdrop will vary from 0 60V to 0 90V Typical 0 65V depending on the...

Страница 14: ...arth wire or to the machine ground Fig 7 2 of 3 Phase System Input Operation Connection Diagram 2 of 3 Phase System Input Operation Delta s CliQ can use on 2 of 3 phase system Please refer to the foll...

Страница 15: ...environment complying with EN 61000 3 2 is only necessary under special conditions Complying to this standard can have some technical drawbacks such as lower efficiency as well as some commercial aspe...

Отзывы: