Chapter 9 Specifications
CFP2000
9-4
General Specifications
Contro
l Char
ac
teristics
Control Method
Pulse-Width Modulation (PWM)
Control Mode
1: V/F, 2: SVC, 3: PMSVC
Starting Torque
Reach up to 150% above at 0.5 Hz.
V/F Curve
4 point adjustable V/F curve and square curve
Speed Response Ability 5 Hz (vector control can reach up to 40 Hz)
Torque Limit
Light duty: max. 130% torque current
Normal duty: max. 160% torque current
Torque Accuracy
5%
Max. Output Frequency
(Hz)
599.00 Hz
Frequency Output
Accuracy
Digital command:
0.01%, -10°C– +40°C; Analog command:
0.1%, 25
10°C
Output Frequency
Resolution
Digital command: 0.01 Hz
Analog command: 0.03 X max. output frequency / 60 Hz (
11 bit)
Overload Tolerance
Light duty: 120% of rated current can endure for 1 minute
Normal duty: 120% of rated current can endure for1 minute; 160% of rated current can endure
for 3 sec.
Frequency Setting Signal 0– +10V, 4–20 mA, 0–20 mA
Accel./decel. Time
0.00–600.00 / 0.0–6000.0 seconds
Main control function
Momentary power loss ride thru, Speed search, Over-torque detection, Torque limit, 16-step
speed (max), Accel/Decel time switch, S-curve accel./decel., 3-wire sequence, Auto-Tuning,
Dwell, Slip compensation, Torque compensation, JOG frequency, Frequency upper/lower limit
settings, DC injection braking at start/stop, High slip braking, PID control (with sleep
function),Energy saving control, Modbus communication (RS-485 RJ45, max. 5.2 Kbps)
Fan Control
Models above VFD300FP4E (incloudingVFD300FP4E) are PWM control
Models below VFD220FP4E (including VFD220FP4E) are ON/OFF switch control
Protection C
ha
racteristics
Motor Protection
Electronic thermal relay protection
Over-current Protection Over-current protection: 185% rated current for light duty; 240% rated current for normal duty
Current clamp:
『
Light duty: 130–135%
』
;
『
Normal duty: 170–175%
』
Over-voltage Protection Drive will stop when DC bus voltage exceeds 820V
Over-temperature
Protection
Built-in temperature sensor
Stall Prevention
Stall prevention during acceleration, deceleration and running independently
Restart After
Instantaneous Power
Failure
Parameter setting up to 20 seconds
Grounding Leakage
Current Protection
Leakage current is higher than 50% of rated current of the AC motor drive
Short-circuit Current
Rating (SCCR)
Per UL508C, the drive is suitable for use on a circuit capable of delivering not more than 100
kA symmetrical amperes (rms) when protected by fuses given in the fuse table.
Certifications
,
, GB/T12668-2
,
RCM,
Содержание CFP2000 Series
Страница 3: ......
Страница 12: ...Chapter 1 Introduction CFP2000 1 3 1 2 Model Name 1 3 Serial Number ...
Страница 15: ...Chapter 1 Introduction CFP2000 1 6 Frame B RFI 1 RFI 1 RFI 1 RFI 2 RFI 2 RFI 2 Figure 1 5 ...
Страница 37: ...Chapter 1 Introduction CFP2000 1 28 1 7 Digital Keypad KPC CC01 ...
Страница 42: ...Chapter 3 Unpacking CFP2000 3 1 Chapter 3 Unpacking 3 1 Unpacking 3 2 The Lifting Hook ...
Страница 54: ...Chapter 4 Wiring CFP2000 4 5 Figure 4 4 ...
Страница 55: ...Chapter 4 Wiring CFP2000 4 6 4 2 1 SINK NPN SOURCE PNP Mode Figure 4 5 Figure 4 6 Figure 4 7 Figure 4 8 ...
Страница 57: ...Chapter 4 Wiring CFP2000 4 8 4 4 Basic Waterproof Component Wiring Diagram Frame A Frame B ...
Страница 58: ...Chapter 4 Wiring CFP2000 4 9 Frame C D0 ...
Страница 75: ...Chapter 5 Main Circuit Terminals CFP2000 5 16 This page intentionally left blank ...
Страница 120: ...Chapter 7 Optional Accessories CFP2000 7 35 Wall Mounting Embedded Mounting ...
Страница 137: ...Chapter 7 Optional Accessories CFP2000 7 52 This page intentionally left blank ...
Страница 141: ...Chapter 8 Option Cards CFP2000 8 4 Communication extension card Slot 1 CMC PD01 CMC DN01 CMC EIP01 EMC COP01 CMC PN01 ...
Страница 144: ...Chapter 8 Option Cards CFP2000 8 7 I O Relay Card EMC D42A EMC D611A EMC R6AA EMC BPS01 EMC A22A ...
Страница 146: ...Chapter 8 Option Cards CFP2000 8 9 I O Relay Card EMC D42A EMC D611A EMC R6AA EMC BPS01 EMC A22A ...
Страница 173: ...Chapter 9 Specifications CFP2000 9 8 9 5 Efficiency Curve Figure 9 5 ...
Страница 245: ...Chapter 11 Summary of Parameter Settings CFP2000 11 36 11 Advanced Parameters Group 11 Advanced Parameters are reserved ...
Страница 251: ...Chapter 11 Summary of Parameter Settings CFP2000 11 42 This page intentionally left blank ...
Страница 304: ...Chapter 12 Description of Parameter Settings CFP2000 12 1 03 3 3 4 5 ...
Страница 305: ...Chapter 12 Description of Parameter Settings CFP2000 12 1 03 4 6 7 8 ...
Страница 306: ...Chapter 12 Description of Parameter Settings CFP2000 12 1 03 5 9 10 11 ...
Страница 307: ...Chapter 12 Description of Parameter Settings CFP2000 12 1 03 6 12 13 14 ...
Страница 308: ...Chapter 12 Description of Parameter Settings CFP2000 12 1 03 7 15 16 17 ...
Страница 309: ...Chapter 12 Description of Parameter Settings CFP2000 12 1 03 8 18 19 20 ...
Страница 310: ...Chapter 12 Description of Parameter Settings CFP2000 12 1 03 9 21 22 23 ...
Страница 311: ...Chapter 12 Description of Parameter Settings CFP2000 12 1 03 10 24 25 26 ...
Страница 312: ...Chapter 12 Description of Parameter Settings CFP2000 12 1 03 11 27 28 29 ...
Страница 313: ...Chapter 12 Description of Parameter Settings CFP2000 12 1 03 12 30 31 32 ...
Страница 314: ...Chapter 12 Description of Parameter Settings CFP2000 12 1 03 13 33 34 35 ...
Страница 315: ...Chapter 12 Description of Parameter Settings CFP2000 12 1 03 14 36 37 38 ...
Страница 326: ...Chapter 12 Description of Parameter Settings CFP2000 12 1 03 25 ...
Страница 415: ...12 Description of Parameter Setting CFP2000 12 1 11 1 11 Advanced Parameters Group 11 Advanced parameters are reserved ...
Страница 449: ...Chapter 12 Description of Parameter Settings CFP2000 12 2 00 6 III PM SVC Carrier Start up Adjustment ...
Страница 451: ...Chapter 12 Description of Parameter Settings CFP2000 12 2 00 8 This page intentionally left blank ...
Страница 545: ...Chapter 14 Fault Codes and Descriptions CFP2000 14 50 This page intentionally left blank ...
Страница 725: ...Chapter 16 PLC Function Applications CFP2000 16 152 Step 3 Physical configuration Step 4 Write to PLC program ...
Страница 726: ...Chapter 16 PLC Function Applications CFP2000 16 153 ...
Страница 728: ...Chapter 16 PLC Function Applications CFP2000 16 155 ...
Страница 731: ...Chapter 16 PLC Function Applications CFP2000 16 158 This page intentionally left blank ...
Страница 747: ...Chapter 17 Introduction to BACnet CFP2000 17 16 This page intentionally left blank ...