BX6.3_DD
Installation
Inverter connection
Specification
1. Drill 4 holes with Φ16 mm diameter in
dimension 540mm x 220mm.
2. Insert Rawlplugs into the holes.
3. Fix the foot of BX6.3_DD firmly.
4. Tighten the nut to stretch the rawlplug.
Insert Rawlplug
①
②
③
④
Wiring
PF pipe(mm)
Conduit hole(mm)
Φ
28
Φ
34
Φ
22
Φ
27
Screw torque:
0.8 N·m (8 kgf·cm)
220
mm
540mm
DC+
Inverter
DC-
H4 Connector
(blue)
Inverter
③
②
①
④
①
CAN -
②
CAN +
③
GND
④
VCC
Communication
connector
100 mm
>30 mm*
100 mm
100 mm
100 mm
90
°
Please keep enough space
for wiring and pipping.
(Max.: 400 mm)
* Please refer to regulation AS/NZS 5139:2019 for detail installation space requirement.
To avoid extra fireproof cement sheeting installation requirement, it is recommended
to keep at least 300mm between the wall and BX.
>500 mm
(max.:10m)
Model
GENERAL
Enclosure
Operating temperature
Relative humidity
Galvanic isolation
Safety class
Type
Battery Module
Typical Energy
Typical Voltage
Voltage Range
BX6.3_DD
BX6.3_DD+BX6.3_EX100
Aluminum with powder coating
-10
℃ *
~ 45
℃
0% – 95% non-condensing.
Operating Altitude
0 to 2000m (0 to 6666 ft.)
NO
Environmental category
Indoor / Outdoor
Protection degree
IP65 (Electronics)
Pollution degree
PD 2
Overvoltage category
Other: not connected to mains directly
Class I metal enclosure with protective earth
Weight
Dimensions(W*H*D)
570 × 840 × 250 mm
570 × 840 × 250 mm
+ 520 × 600 × 230 mm
Connectors
Weather resistant connectors
Audible noise
< 40dB
Li-ion
Depth of Discharge
(DoD)
98%
Samsung SDI 41J (21700)
6.3 kWh
DC 202.7 V
DC 175 - 228 V
12.6 kWh
DC 405.4 V
DC 350 - 456 V
BT INPUT
75kg
75 kg (BX6.3_DD)
+ 60 kg (BX6.3_EX)
Voltage
Maximum input/
output current
Tare loss
Nominal power
3000 W
Maximum power
3000 W
6000 W
6000 W
250V - 1000V
15.6 A
15.6 A
< 10 W
Maximum fault current
25A
Maximum efficiency
99%
DC BUS INPUT / OUTPUT
Electrical safety
IEC 62619:2017, IEC 60730-1:2013
REGULATIONS & DIRECTIVES
Version 20220803