3.
SLM80-110LED
HI
POWER SWITCH
LIGHT SWITCH
JUNCTION BOX
SWITCH BOX
WHITE
BLACK
OFF
ON
RED
GRD
L
N
L
N
GREEN
WHITE
BLACK
ON/OFF SWITCH
(purchase separately)
SWITCH BOX
120 VAC
LINE IN
WHITE
GROUND
(bare)
POWER
SWITCH
WIRING
PLATE
LIGHT
SWITCH
RED
4.
SLM80-110DLED
HI
POWER SWITCH
MODE SWITCH
JUNCTION BOX
SWITCH BOX
WHITE
BLACK
OFF
ON
BLUE
GREEN
GRD
L
N
L
N
ON
LIGHT SWITCH
RED
L
N
WHITE
WHITE
BLACK
ON/OFF SWITCH
(purchase separately)
SWITCH BOX
120 VAC
LINE IN
WHITE
GROUND
(bare)
POWER
SWITCH
WIRING
PLATE
MODE
SWITCH
LIGHT
SWITCH
RED
BLUE
OTHER WIRING OPTION
See OPERATION section for detail description of ‘‘mode’’.
5.
SLM80-110D
Hardwire power.
Switch OFF: Fan runs 24 hours at ‘‘Low speed control
mode’’.
Switch ON : Fan runs at user adjustable full speed
airflow.
ON
SWITCH
JUNCTION BOX
SWITCH BOX
WHITE
BLACK
BLUE
GRD
N
L
N
GREEN
WHITE
OFF
BLACK
ON/OFF SWITCH
(purchase separately)
SWITCH BOX
120 VAC
LINE IN
WHITE
GROUND
(bare)
WIRING
PLATE
BLUE
6.
SLM80-110LED
Combine power & light to one switch.
Switch ON : Fan runs at user adjustable full speed
airflow and the light on at the same time.
JUNCTION BOX
SWITCH BOX
WHITE
BLACK
OFF
ON
RED
GRD
L
N
N
GREEN
WHITE
SWITCH
BLACK
ON/OFF SWITCH
(purchase separately)
SWITCH BOX
120 VAC
LINE IN
WHITE
GROUND
(bare)
WIRING
PLATE
RED
7.
SLM80-110DLED
Hardwire power and combine mode & light to one switch.
Switch OFF: Fan runs 24 hours at ‘‘Low speed control
mode’’.
Switch ON: Fan runs ‘‘Full speed control mode’’ and
light on at the same time.
ON
JUNCTION BOX
SWITCH BOX
WHITE
BLACK
BLUE
GREEN
GRD
N
N
RED
N
WHITE
WHITE
L
OFF
SWITCH
L
BLACK
GROUND
(bare)
SWITCH BOX
120 VAC
LINE IN
WHITE
WIRING
PLATE
RED
BLUE
ON/OFF SWITCH
(purchase separately)
OPERATION
Single Speed Models:
SLM80-110, SLM80-110LED
HVI LABEL
LED indicator
Full speed air volume
preset control
1
10
8
0
Turn the POWER switch on to operate at user
adjustable full speed airflow - the LED indicator will be
green.
Dual Speed Models:
SLM80-110D, SLM80-110DLED
HVI LABEL
05
0
LOW SPEED
CFM
0.5
45
15 5
TIME (min)
80
30
60
Delay time control
LED indicator
Full speed air volume
preset control
Low speed air volume
preset control
1
10
80
Low speed control mode: Turn the POWER switch on
(MODE switch is off ) to operate at the user-adjustable
low speed airflow - the LED will be green.
Full speed control mode: Turn the POWER switch &
MODE switch on to operate at user-adjustable full
speed mode - the LED indicator will be amber. When
the user turns the MODE switch off, the fan will
continue to run at the full speed until the user-
adjustable time delay has elapsed, and then will
automatically change to the user-adjustable low speed
airflow. The LED indicator will be green.
Factory setting: High speed airflow 110CFM, low speed
airflow 50CFM, time delay 5 minutes.
GRILLE INSTALLATION
1.
LED Models :
Insert the LED lighting connector into the power
socket of main body.
2.
All Models :
Insert the mounting springs into the slots and mount
the grille to the fan body.
Slots
Lighting Connector
CARE AND MAINTENANCE
TURN OFF POWER SOURCE. REVIEW ALL
SAFETY PRECAUTION.
See safety information before proceeding. Routine
maintenance should be done at least once a year.
Never use solvents, thinner or harsh chemicals when
cleaning the fan.
Do not allow water to enter the motor.
Do not immerse metal parts in water.
Do not immerse resin parts in water over 140º F.
1.
To remove grille, squeeze springs and pull down. Wash
and clean grille with non-abrasive kitchen detergent.
Then wipe dry with a new cloth.
2.
Remove dust and dirt from the fan body with a
vacuum cleaner.
3.
Using a cloth dampened with non-abrasive kitchen
detergent, remove dust and dirt from the fan body.
Then wipe dry with new cloth.
4.
Replace the grille back onto the fan body. Turn on fan
switch to operate fan again.
Page 3.
4.
3.
1.
2.