Proper insulation around the fan to minimize building
heat loss and gain.
Page 2.
MODELS SLM50 / SLM70
INSTALLATIONS
Install with wood frame
Model No.
SLM50
SLM70
Install Dim.
(Inch)
7.5X7.25
7.5X7.25
1.
Remove the motor plate from the housing by
removing the three screws.
(Fig. C)
2.
Remove the wiring cover from the housing by
pulling straight out. Choose a hole and use a
slotted screwdriver to remove it.
(Fig. D)
3.
Follow all local electrical and safety codes.
NEVER
place a switch where it can be reached
from a tub or shower. Connect wires as shown in
wiring diagrams.
(Fig. E)
4.
Using wire nuts , connect the house power cable
to the ventilating fan wires. 14 AWG (2.1 mm
2
) is
the smallest conductor that shall be used for
branch-circuit wiring.
(Fig. F)
5.
Insert the duct into the duct connector and tape
all ductwork connection s to make them secure
and air tight. Install the duct with a gradient 1°~2°
to the outside.
(Fig. G)
6.
New installation prior to finishing the ceiling
or wall:
Insert the fan between joists. Make sure
the fan body is level and perpendicular with the
joist.
(Fig. H)
7.
Replacement installation:
After making
electrical and ductwork connections (see steps
2~5),
nail the housing in place. Drive nails through the
housing w here indicated by arrows.
(Fig. I)
8.
New installation in an existing ceiling or wall:
Bend tabs outward 90°(Use a screw driver if desired)
and position housing so that tabs rest against
the bottom edge of the joists (or front of stud). Nail
the housing to the joist or stud using four nails to
ensure a solid, quiet installation. Ceiling installations:
Tabs on the opposite side of the housing can be
bent outward to rest on top of 1/2" ceiling material
and provide extra stability.
(Fig. J)
9.
Plug in the motor and lock the fan body back by
using three screws.
(Fig. C)
10. Squeeze the grille springs together and insert the
springs into the slots in the motor plate. Push the
grille up against the ceiling or wall. When the
power is on, check for abnormal vibrations or
sounds. Insert the mounting springs into the slots
and mount the grille to the body.
(Fig. K)
(Fig. C)
Open chosen hole
(Fig. D)
(Fig. C)
Receptacle
Plug
connector
Fig. E
Off
On
Fig. F
Fig. G
Wire nut
Power cable
Compartment
Ventilation Fan
Black
White
Green
Switch Box
(Purchase Separately)
Live
Neutral
Ground
Fig. H
Fig. H
Tapping screw
Fig. H
Fig. I
Fig. J
Fig. K
Nail
Stud
Tabs
WARRANTY
DELTA ELECTRONICS THREE YEARS
LIMITTED WARRANTY
Delta Electronics Inc. (“Delta Electronics”) warrants to the
original consumer purchaser in the USA and Canada that
the Breez ventilation fan products will be free from defects
in material or workmanship. This warranty is limited to
three (3) years from the original date of purchase.
Limitations and Exclusions
During the warranty period, a replacement for any
defective product will be supplied free of charge for
installation by the consumer. The warranty provided
herein does not cover charges for labor or other costs
incurred in the troubleshooting, repair, removal, and
installation service.
All returns of defective parts or products must
include the product model number, and must be
made through an authorized Delta Electronics
distributor. Authorized returns must be shipped
prepaid. Repaired or replacement products will be
shipped by Delta Electronics F.O.B. shipping point.
Delta Electronics shall not be liable for any indirect,
incidental, consequential, punitive, or special damages
arising out of or in connection with products use or
performance, regardless of the form of action
whether in contract, tort (including negligence), strict
product liability or otherwise.
This warranty does not extend to fluorescent lamp
starters and tubes.
The warranty does not cover if user does not comply with
manufacture’s installation manual.
To qualify for warranty service, you must notify Delta
Electronics at the address or telephone number below.
Delta Electronics shall have no liability to the original
owner-user with respect to any defect caused by abuse,
misuse, neglect, improper transportation or storage,
improper testing, improper installation, improper
operation, improper use, improper maintenance,
improper repair, improper alteration, improper
modification, tampering or accident of products or parts
thereof, or unusual deterioration or degradation of
products or parts thereof due to a physical environment
beyond the requirements of products’ specifications.
Address: 46101 Fremont Boulevard, Fremont, CA 94538
US Toll Free Number: 1-888-979-9889