MODELS:
GBR80 / GBR100
Page 2.
Joist
Screw 4×25
Screw 4×25
Joist
USING HANGER BAR
1-3.
Sliding hanger bars available to allow for your
specific positioning of housing anywhere between joists
and span up to 24’’.
1-4.
Insert hanger bars into the channels on housing.
Make sure tabs face ‘‘up’’ shown.
Hanger Bar
Channel
1-5.
Extend hanger bars to the width of the joists.
Hold fan in place with the hanger bars tabs wrapping
around the bottom of joist.
1-6.
Fasten hanger bars to joists with nails or screws
through holes near nails.
1-7.
Secure hanger bars together with screws.
Screw
Joist
Joist
2. DUCT CONNECTION
2-1.
Insert the duct into the duct connector and tape
all ductworks connection to make them secure and air
tight.
2-2.
Install the duct with a gradient 1°~2° to the
outside.
Inside
Outside
Duct
Body
Gradient
1°~2°
Ceiling
Grille
Tape
Duct Connector
3. CONNECT WIRING
3-1.
Follow all local electrical and safety codes,
ANSI/NFPA70.
3-2.
NEVER place a switch where it can be reached
from a tub or shower.
3-3.
Connect wires as shown in wiring diagrams.
POWER SWITCH
JUNCTION BOX
SWITCH BOX
WHITE
BLACK
OFF
ON
GREEN
GRD
L
N
ON/OFF SWITCH
(purchase separately)
SWITCH BOX
120 VAC
LINE IN
WIRING
PLATE
BLACK
WHITE
GROUND
(bare)
POWER
SWITCH
3-4.
Using wire nuts (not provided), connect house
power cable to ventilating fan.
3-5.
14 AWG (2.1 mm
2
) is the smallest conductor that
shall be used for branch-circuit wiring.
4. TEST RUN & GRILLE ATTACHMENT
4-1.
When the power on, check for abnormal vibration
or sound.
4-2.
Insert the mounting springs into the slots and
mount the grille to the fan unit.
Grille
Spring
Slots
5. OPERATION
5-1.
Turn on the power switch to operate ON or OFF,
and LED indicator is green.
6. MAINTENANCE
WARNING:
Disconnect power source before working on unit.
Routine maintenance must be done every year.
CAUTION:
1.
Never use gasoline, benzene, thinner or any other
such chemicals for cleaning the ventilating fan.
2.
Do not allow water to enter motor.
3.
Do not soak resin parts in water over 140°F (60°C).
CLEANING
:
1.
Pull down the spring to remove grille.
2.
Wash and clean grille. (Use non-abrasive kitchen
detergent, wipe dry with new cloth.)
3.
Using a cloth dampened with non-abrasive
kitchen detergent, remove dust and dirt from
ventilating fan. Wipe dry with new cloth.
4.
Replace grille.
DIMENSIONS
10
3/4
"
10
3/4
"
8
"
8
1/4
"
5
3/4
"
4" DUCT
8
1/4
"
5
3/4
"
1"
10
3/4
"
10
3/4
"
SPECIFICATIONS
Model No.
Voltage
(V)
Frequency
(Hz)
Power
@ 0.1SP
(W)
Air Flow
@ 0.1SP
(CFM)
Weight
(lb.)
GBR80 120 60
10.5 80 5.6
GBR100
120 60 12.6 100 5.6
Note: Design and specifications subject to change without notice.
WARRANTY
DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY
Delta Electronics Inc. (“Delta Electronics”) warrants to the
original consumer purchaser in the USA and Canada that
the Breez ventilation fan products will be free from defects
in material or workmanship. This warranty is limited to
three (3) years from the original date of purchase.
Limitations and Exclusions
1. During the warranty period, a replacement for any
defective product will be supplied free of charge for
installation by the consumer. The warranty provided
herein does not cover charges for labor or other costs
incurred in the troubleshooting, repair, removal, and
installation service.
2. All returns of defective parts or products must include
the product model number, and must be made through
an authorized Delta Electronics distributor. Authorized
returns must be shipped prepaid. Repaired or
replacement products will be shipped by Delta
Electronics F.O.B. shipping point.
3. Delta Electronics shall not be liable for any indirect,
incidental, consequential, punitive, or special damages
arising out of or in connection with products use or
performance, regardless of the form of action whether in
contract, tort (including negligence), strict product
liability or otherwise.
4. This warranty does not extend to fluorescent lamp
starters and tubes.
5. The warranty does not cover if user does not comply
with manufacture’s installation manual.
6. To qualify for warranty service, you must notify Delta
Electronics at the address or telephone number below.
7. Delta Electronics shall have no liability to the original
owner-user with respect to any defect caused by abuse,
misuse, neglect, improper transportation or storage,
improper testing, improper installation, improper
operation, improper use, improper maintenance,
improper repair, improper alteration, improper
modification, tampering or accident of products or parts
thereof, or unusual deterioration or degradation of
products or parts thereof due to a physical environment
beyond the requirements of products’ specifications.
Address: 46101 Fremont Boulevard, Fremont, CA 94538
US Toll Free Number:
1-888-979-9889 - Technical Support
1-877-685-4384 - Customer Sales Support