background image

 
 
 

 

 
 

 

MODELS:

 GBR80 / GBR100 

Page 1. 

INSTALLATION AND OPERATING INSTRUCTIONS 

CEILING/WALL VENTILATION FAN 

   

READ AND SAVE THESE INSTRUCTIONS 

GENERAL SAFETY INFORMATION 

1.

 

Make sure that the electric service supply voltage is 
AC 120V, 60Hz. 

2.

 

Follow all local electrical and safety codes, as well as 
the Nation Electrical Code (NEC) and the 
Occupation Safety and Healthy Act (OSH Act). 

3.

 

Always disconnect the power source before 
working on or near the ventilating fan, motor or 
junction box. 

4.

 

Protect the power cord from sharp edges, oil, grease, 
hot surfaces, chemicals or other objects. 

5.

 

Do not kink the power cord. 

6.

 

Do not install the unit where ducts are configured 
as shown in Fig. A. 

7.

 

Provide suction parts with proper ventilation. 

8.

 

This unit is UL listed for use over a bathtub or 
shower when installed in a GFCI protected branch 
circuit. 

 

WARNING 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 
INJURY TO PERSONS, OBSERVE THE FOLLOWING: 

1.

 

Use this unit only in the manner intended by the 
manufacturer. If you have questions, contact the 
manufacturer. 

2.

 

Before servicing or cleaning unit, switch power off 
at service panel and lock the service disconnecting 
means to prevent power from being switched on 
accidentally. When the service disconnecting means 
cannot be locked, securely fasten a prominent 
warning device, such as a tag, to the service panel. 

3.

 

Installation work and electrical wiring must be done 
by qualified person(s) in accordance with all 
applicable codes and standards, including fire-rated 
construction. 

4.

 

Sufficient air is needed for proper combustion and 
exhausting of gases through the flue (chimney) of 
fuel burning equipment to prevent back drafting. 
Follow the heating equipment manufacturer’s 
guideline and safety standards such as those 
published by the National Fire Protection 
Association (NFPA), and the American Society of 
Heating, Refrigerating and Air-Conditioning 
Engineers (ASHRAE), and the local code authorities. 

5.

 

When cutting or drilling into wall or ceiling, do not 
damage electrical wiring and other hidden utilities. 

6.

 

Ducted fans must always be vented to the outdoors. 

7.

 

If this unit is to be installed over a tub or shower, it 

must be marked as appropriate for the application 
and be connected to a GFCI (Ground Fault Circuit 
Interrupter) --- protected branch circuit. 

8.

 

Do not use this unit with any other solid-state 
control devices. Solid-state control devices may 
cause harmonic distortion, which can cause a motor 
humming noise. (Avertissement: ne convient pas à 
des régulateurs de vitesse à semi-conducteurs). 

9.

 

NEVER place a switch where it can be reached from 
a tub or shower. 

10.

 

Not to be installed in a ceiling thermally insulated to 
a value greater than R50. (This is required for 
installation in Canada only). 

Turning angle too large

Duct shrink

Too many elbows

Elbow near the body

Body

 

Fig. A 

CAUTION

 

1.

 

For General Ventilating Use Only. Do Not Use To 
Exhaust Hazardous Or Explosive Materials And 
Vapors. 

2.

 

Not for use in cooking areas. (Fig. B) 

3.

 

This product must properly connect to the 
grounding conductor of the supply circuit. 

4.

 

To reduce the risk of injury to persons, install the 
fan at least 8.2 feet (2.5m) above the floor. 

45

Cooking area

45

Do not install above or

inside this area

 Cooking

Equipment

floor

 

 

SUPPLIED ACCESSORIES 

Part name 

Appearance 

Quantity 

Grille 

 

Fan 

 

Housing 

 

Duct 

Connector

 

(4’’) 

 

Tapping 

Screw 

(Ø4×25) 

 

Machine 

Screw  

(#8-32x5/16’’) 

 

Hanger Bar

 

 

1. INSTALLATIONS 

Proper insulation around the fan to minimize building 
heat loss and gain. 4’’ circular duct is recommended for 
installation. The ducting from this fan to the outside of 
the building has a strong effect on the air flow, noise 
and energy use of the fan. Use the shortest, straightest 
duct routing possible for best performance, and avoid 
installing the fan with smaller ducts than 
recommended. Insulation around the ducts can 
reduce energy loss and inhibit mold growth. Fans 
installed with existing ducts may not achieve their 
rated air flow. 

 

MOUNT HOUSING WITH FLANGE(CELING/ WALL) 

1-1.

 

To bend the housing tabs out to 90 degree and 
make housing tabs contact the bottom or front of 
the joist. 

Tabs

Joist

 

Tabs

Joist

 

1-2.

 

The housing mounts with 4 screws (Ø4×25). 
Screw housing to joist through lowest holes in 
each mounting flange, then through the other 
holes.

 

 

Fig. B 

 

Отзывы: