Test Operation and Panel Display ASDA-B3
4-20
4
4.5.4 Trial run without load (Speed mode)
Before starting the trial run without load, firmly secure the motor base to avoid any danger
caused by force generated by the motor during speed changes.
Step 1: set the control mode of the servo drive to Speed mode. Set P1.001 to 2 for Speed mode.
Then cycle the power to the servo drive.
Step 2: in Speed mode, the following table lists the digital input settings for the trial run.
Digital input
Parameter setting value
Symbol
Function description
CN1 Pin No.
DI1
P2.010 = 101
SON
Servo activated
DI1- = 9
DI2
P2.011 = 109
TRQLM
Torque limit
DI2- = 10
DI3
P2.012 = 114
SPD0
Speed selection
DI3- = 34
DI4
P2.013 = 115
SPD1
Speed selection
DI4- = 8
DI5
P2.014 = 102
ARST
Alarm reset
DI5- = 33
DI6
P2.015 = 0
-
DI disabled
-
DI7
P2.016 = 0
-
DI disabled
-
DI8
P2.017 = 0
-
DI disabled
-
DI9
P2.036 = 0
-
DI disabled
-
DI10
P2.037 = 0
-
DI disabled
-
DI11
P2.038 = 0
-
DI disabled
-
DI12
P2.039 = 0
-
DI disabled
-
DI13
P2.040 = 0
-
DI disabled
-
This table shows the settings that disable the negative limit (DI6), positive limit (DI7), and
emergency stop (DI8) functions. Thus, parameters P2.015 - P2.017 and P2.036 - P2.040 are set
to 0 (disabled). You can program the digital inputs of Delta’s servo drive. When programming the
digital inputs for the servo drive, refer to Table 8.1 Digital input (DI) descriptions in Chapter 8.
The default setting includes the negative limit, positive limit, and emergency stop functions.
Therefore, if any alarm occurs after you complete the settings, cycle the power to the servo
drive or set DI5 to On to clear the error. Refer to Section 4.5.2.
Содержание ASDA-B3 Series
Страница 15: ... This page is intentionally left blank ...
Страница 53: ...Installation ASDA B3 2 24 2 This page is intentionally left blank ...
Страница 137: ...Wiring ASDA B3 3 84 3 This page is intentionally left blank ...
Страница 161: ...Test Operation and Panel Display ASDA B3 4 24 4 This page is intentionally left blank ...
Страница 285: ...Motion Control ASDA B3 7 66 7 This page is intentionally left blank ...
Страница 477: ...Parameters ASDA B3 8 192 8 This page is intentionally left blank ...
Страница 515: ...Absolute System ASDA B3 10 22 10 This page is intentionally left blank ...
Страница 747: ...Troubleshooting ASDA B3 13 54 13 This page is intentionally left blank ...
Страница 809: ...Accessories ASDA B3 B 32 B This page is intentionally left blank ...
Страница 813: ...Revision History ASDA B3 4 This page is intentionally left blank ...