ASDA-M Chapter 5 Trial Operation and Tuning
Revision December, 2014
5-9
5.5 Trial Run without Load (Position Mode)
Before the trial run without load, firmly secure the motor base so as to avoid the danger
cause by the reaction of motor operation.
STEP 1:
Set the control mode of the servo drive to position mode.
Firstly select the desired axis for speed test, and set parameter P1-01 to 1. Then, re-power
on the servo drive.
STEP 2:
In position mode, the digital input settings of trial run are as follows:
Digital Input
Parameter
Setting Value
Symbol
Function Description
CN1 Pin No
DI1
P2-10 = 101
SON
Servo ON
DI1- = 9
DI2
P2-11 = 108
CTRG
Torque limit
DI2- = 10
DI3
P2-12 = 111
POS0
Position command
selection
DI3- = 34
DI4
P2-13 = 112
POS1
Position command
selection
DI4- = 8
DI5
P2-14 = 102
ARST
Alarm reset
DI5- = 33
DI6
P2-15 = 0
Disabled
Invalid DI function
-
The above table disables the function of emergency stop (DI6) (the default setting), thus,
set P2-15 to 0 (Disabled). The digital input of Delta
’
s servo drive can be programmed by
users. When programming digital input, please refer to the description of DI code.
The default setting includes the function of negative limit, positive limit and emergency stop,
therefore, after the setting is completed, if there is any alarm occurs, please re-power on
the servo drive or switch ON DI5 to clear the alarm. Please refer to Chapter 5.2.
Содержание ASD-M-0721 Series
Страница 20: ...ASDA M Chapter 1 Inspection and Model Explanation Revision December 2014 1 7 ASDA M Series Servo Drive top view...
Страница 36: ...ASDA M Chapter 2 Installation Revision December 2014 2 15 Delta Part Number BR1K5W005 3kW 10...
Страница 37: ...Chapter 2 Installation ASDA M 2 16 Revision December 2014 This page is intentionally left blank...
Страница 161: ...Chapter 6 Control Mode of Operation ASDA M 6 36 Revision December 2014 Frequency Domain...
Страница 231: ...Chapter 7 Motion Control ASDA M 7 44 Revision December 2014 This page is intentionally left blank...
Страница 631: ...ASDA M Appendix A Accessories A 10 Revision December 2014 RS 485 Connector Delta Part Number ASD CNIE0B06...
Страница 645: ...Appendix B Maintenance and Inspection ASDA M B 4 Revision December 2014 This page is intentionally left blank...