Wiring ASDA-A3
3-52
Revision December, 2017
3
3.10.3 Wiring for STO
To use a safety relay to trigger the STO function, please connect the wiring as shown in the
following diagram:
ESTOP
2
3
4
5
6
7
8
STO_A
/ STO_A
STO_B
/ STO_B
FDBK+
FDBK-
Reserved
STO
24V DC
Safety Relay
1
Reserved
If you are not using the STO function, you can short-circuit the connector or plug in the connector
that has been wired (provided with the servo drive).
1
3
4
5
6
7
8
STO
STO_A
/ STO_A
STO_B
/ STO_B
FDBK+
FDBK-
Reserved
2
Reserved