background image

12- ENG

A08590

How to Use Your Unit

How to Stop:

1.  Set the On/Auto/Off lever to "OFF".

Check Valve:

  When the air compressor is 

operating, the check valve is "open", allowing 

compressed air to enter the air tank.  When the air 

compressor reaches "cut-out" pressure, the check 

valve "closes", allowing air pressure to remain inside 

the air tank.

Check Valve

Before Starting  

Break-in Procedure

Risk of Unsafe Operation. Serious damage may result if 

the following break-in instructions are not  

closely followed.

This procedure is required 

before

 the air compressor is put into service and 

when the check valve or a complete compressor pump has been replaced.
1.  Make sure the On/Auto/Off lever is in the "Off" position.

NOTE:

 Pull coupler back until it clicks to prevent air from escaping through the 

quick connect.
2.  Plug the power cord into the correct branch circuit receptacle. (Refer to 

Voltage and Circuit Protection paragraph in the Installation section of this 

manual.)

3.  Open the drain valve fully (counterclockwise) to permit air to escape and 

prevent air pressure build up in the air tank during the break-in period.

4.  Move the On/Auto/Off lever to "On/Auto" position. The compressor will start.
5.  Run the compressor for 15 minutes. Make sure the drain valve is open and 

there is minimal air pressure build-up in tank.

6.  After 15 minutes, close the drain valve (clockwise). The air receiver will fill 

to "cut-out" pressure and the motor will  stop. 

The compressor is now ready for use.

Before Each Start-Up:

1.  Place On/Auto/Off lever to "OFF".
2.  Pull regulator knob out, turn counterclockwise until it stops. Push knob in 

to lock in place.

3.  Attach hose and accessories.

 NOTE:

 The hose or accessory will require a 

quick connect plug if the air outlet is equipped with a quick connect  
socket. 

Too much air pressure causes a hazardous risk 
of bursting. Check the manufacturer’s maximum 

pressure rating for air tools and accessories. The regulator outlet 
pressure must never exceed the maximum pressure rating.

Содержание 66-202-1

Страница 1: ...right 2005 Delta Machinery To learn more about DELTA MACHINERY visit our website at www deltamachinery com For Parts Service Warranty or other Assistance please call 1 866 422 4286 Oil Free Air Compre...

Страница 2: ...the symbols below Please read the manual and pay attention to these symbols IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities...

Страница 3: ...roperty damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent va...

Страница 4: ...ndensed water from tank causing rust and thinning of the steel tank Modifications or attempted repairs to the tank Unauthorized modifications to the unloader valve safety valve or any other components...

Страница 5: ...ect voltage and adequate fuse protection The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid particles from the...

Страница 6: ...thing WARNING Risk of Falling A portable compressor can fall from a table workbench or roof causing damage to the compressor and could result in serious injury or death to the operator Always operate...

Страница 7: ...parts WARNING Risk of Unsafe Operation Unsafe operation of your air compressor could lead to serious injury or death to you or others HAZARD WARNING Risk of Serious Injury or Property Damage When Tran...

Страница 8: ...Underwriters Laboratories Standards for Safety Cut In Pressure While the motor is off air tank pressure drops as you continue to use your accessory When the tank pressure drops to a certain low level...

Страница 9: ...hat has been installed and grounded in accordance with all local codes and ordinances 1 The cord set and plug with this unit contains a grounding pin This plug MUST be used with a grounded outlet IMPO...

Страница 10: ...or if operation of the compressor repeatedly causes interruption of the power it may be necessary to operate it from a 20 amp circuit It is not necessary to change the cord set Extension Cords Using...

Страница 11: ...et Pressure Gauge The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator This pressure is controlled by the regulator and is always less than or equal to th...

Страница 12: ...t Protection paragraph in the Installation section of this manual 3 Open the drain valve fully counterclockwise to permit air to escape and prevent air pressure build up in the air tank during the bre...

Страница 13: ...g compressor pull the ring on the safety valve to make sure that the safety valve operates freely If the valve is stuck or does not operate smoothly it must be replaced with the same type of valve To...

Страница 14: ...lve threads Reinstall the check valve turn clockwise 7 Replace the outlet tube and tighten the nut 8 Perform the Break in Procedure See Break in Procedure in the Operation section Check Valve Nut Outl...

Страница 15: ...cheduled maintenance as necessary 2 Set the On Auto Off lever to OFF 3 Turn the regulator counterclockwise and set the outlet pressure to zero 4 Remove the air tool or accessory 5 Pull ring on safety...

Страница 16: ...re air can be heard escaping Check fittings with soapy water solution Do Not Overtighten Air leaks at fittings Air leaks at pressure switch release valve if equipped Defective pressure switch release...

Страница 17: ...accessory is being used Compressor is not supplying enough air to operate accessories Prolonged excessive use of air Compressor is not large enough for air requirement Hole in hose Check valve restric...

Страница 18: ...heck for proper fuse You should use a time delay fuse Check for low voltage problem Check the extension cord Disconnect the other electrical appliances from circuit or operate the compressor on its ow...

Страница 19: ...19 ENG A08590 NOTES...

Страница 20: ...20 ENG A08590 AIR COMPRESSOR DIAGRAM 17 18 16 13 14 12 11 15 8 7 4 5 6 1 2 3 19...

Страница 21: ...r 4 SS 1286 Nipple 5 SSP 6021 Bushing Reducer 6 D20114 Safety Valve 7 Z D27227 Pressure Switch 8 D30198 Nipple 11 D26618 Power Cord Assembly 12 A06891 Drain Valve 13 SST 5314 1 Rubber Bumper 4 14 9189...

Страница 22: ...22 ENG A08590 AIR COMPRESSOR PUMP DIAGRAM 9 3 18 5 6 8 14 17 15 1 2 25 4 Torque 49 55 in lbs Torque 30 45 in lbs Torque 10 in lbs Max 9 13 9 12 9 8 9 9 9 10 9 11 7 10 22 16 24 Torque 30 in lbs...

Страница 23: ...9 11 D21127 Screw 10 24 x 563 9 12 SSF 3147 Screw 3 8 16 x 375 UNC 9 13 Cylinder Sleeve 10 CAC 1206 1 Hose Clamp 14 SUDL 9 1 Screw 8 32 x 375 344 15 D29132 Screw 10 14 x 750 5 16 A02706 Motor Cord 17...

Страница 24: ...Air compressors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Authorized Warranty Service Center that provides on site service calls for service call a...

Отзывы: