ADDITIONAL SAFETY RULES FOR

AIR CLEANERS

1.

DO NOT USE THIS UNIT TO FILTER METAL DUST.

Combining wood and metal dust can cre-

ate an explosion or fire hazard. This unit is intended to filter non-explosive atmospheres only.

2          .

WARNING: DUST GENERATED BY CERTAIN WOODS AND WOOD PRODUCTS CAN BE HAZ-

ARDOUS TO YOUR HEALTH.

3.                          

DO NOT USE THIS UNIT TO DISSIPATE FUMES OR SMOKE

This air cleaner is intended for use

where only dry airborne dust is present. Its use should be limited to non-explosive, non-metallic atmospheres.

4

. DO NOT OPERATE THIS UNIT UNTIL IT IS COMPLETELY ASSEMBLED AND INSTALLED ACCORDING TO

THE INSTRUCTIONS

.

5.

OBTAIN ADVICE FROM YOUR SUPERVISOR, INSTRUCTOR, OR ANOTHER QUALIFIED PERSON 

if you are

not thoroughly familiar with the operation of this unit.

6.

FOLLOW ALL WIRING CODES

and recommended electrical connections.

7.

DO NOT LIFT THIS UNIT BY THE POWER CORD. 

Do not use the power cord as a hanging device.

8.

SECURELY ANCHOR THIS UNIT INTO A SUPPORTING STRUCTURE 

when suspending it from the ceiling.

Always keep a minimum of 7 feet between the bottom of the unit and the floor surface to allow for sufficient head
clearance. Use only chain rated for a minimum of 150 lb. working load to adequately hold the unit. Use steel S-
Hooks that are at least 1/4" in diameter to suspend the unit from the ceiling. Lag-type bolts used to suspend the
unit from the ceiling must be threaded at least 1-1/2" into supporting structural members.

9.

SUPPORT THIS UNIT OR SECURELY CLAMP IT TO THE WORK SURFACE WHEN IT IS USED IN A
PORTABLE APPLICATION

to eliminate potential movement and/or damage from falling.

10.

INSURE THAT THE INTAKE AND EXHAUST AREAS ARE CLEAR PRIOR TO STARTING THE UNIT.

11.

KEEP ARMS, HANDS, AND FINGERS AWAY FROM THE FAN. 

Avoid all exposure to rotating parts.

12.

DO NOT OPERATE THIS UNIT WITHOUT THE FILTERS IN PLACE.

GENERAL SAFETY RULES

Woodworking can be dangerous if safe and proper operating procedures are not followed. As with all machinery,
there are certain hazards involved with the operation of the product. Using the machine with respect and caution
will considerably lessen the possibility of personal injury. However, if normal safety precautions are overlooked or
ignored, personal injury to the operator may result. Safety equipment such as guards, push sticks, hold-downs,
featherboards, goggles, dust masks and hearing protection can reduce your potential for injury. But even the best
guard won’t make up for poor judgment, carelessness or inattention. Always use common sense and exercise
caution in the workshop. If a procedure feels dangerous, don’t try it. Figure out an alternative procedure that feels
safer. 

REMEMBER:

Your personal safety is your responsibility.

This machine was designed for certain applications only. Delta Machinery strongly recommends that this machine
not be modified and/or used for any application other than that for which it was designed. If you have any ques-
tions relative to a particular application, 

DO NOT

use the machine until you have first contacted Delta to deter-

mine if it can or should be performed on the product.

Technical Service Manager
Delta Machinery
4825 Highway 45 North
Jackson, TN 38305

(IN CANADA: 505 SOUTHGATE DRIVE, GUELPH, ONTARIO  N1H 6M7)

FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY.

1.

FOR YOUR OWN SAFETY, READ AND UNDERSTAND THE INSTRUCTION MANUAL BEFORE OPERATING THE

UNIT

. Learn the unit’s application and limitations as well as the specific hazards peculiar to it.

2.

KEEP WORK AREA CLEAN

. Cluttered areas and benches invite accidents.

3.

DON’T USE IN DANGEROUS ENVIRONMENT. 

Don’t use this unit in damp or wet locations, or expose it to rain. Keep

work area well-lighted.

4.

KEEP CHILDREN AND VISITORS AWAY

. All children and visitors should be kept a safe distance from work area.

5.

DISCONNECT UNIT

before servicing.

6.

CHECK DAMAGED PARTS

. Before further use of the unit, properly repair or replace any part that is damaged. 

Содержание 50-868

Страница 1: ...9 651 0004 09 23 02 Copyright 2002 Delta Machinery ESPAÑOL PÁGINA 11 To learn more about DELTA MACHINERY visit our website at www deltamachinery com For Parts Service Warranty or other Assistance please call 1 800 223 7278 In Canada call 1 800 463 3582 ...

Страница 2: ...rking can be dangerous if safe and proper operating procedures are not followed As with all machinery there are certain hazards involved with the operation of the product Using the machine with respect and caution will considerably lessen the possibility of personal injury However if normal safety precautions are overlooked or ignored personal injury to the operator may result Safety equipment suc...

Страница 3: ...es a path of least resistance for electric current to reduce the risk of electric shock This tool is equipped with an electric cord having an equipment grounding conductor and a grounding plug The plug must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordi nances Do not modify the plug provided if it will not fit the outlet have t...

Страница 4: ...Fig A Fig B GROUNDED OUTLET BOX CURRENT CARRYING PRONGS GROUNDING BLADE IS LONGEST OF THE 3 BLADES GROUNDED OUTLET BOX GROUNDING MEANS ADAPTER HOLES HOLES EXTENSION CORDS Use proper extension cords Make sure your extension cord is in good condition and is a 3 wire extension cord which has a 3 prong grounding type plug and a 3 hole receptacle which will accept the machine s plug When using an exten...

Страница 5: ...an overhead support If the Air Cleaner will be used as a mobile unit proceed to USING THE AIR CLEANER ON A BENCH OR FLOOR SURFACE section For overhead or ceiling mounting refer to section MOUNTING THE AIR CLEANER TO A CEILING OR OVERHEAD SUPPORT IMPORTANT When determining where to mount the air cleaner always select a location where the air flow is unrestricted Do not locate the unit in a corner o...

Страница 6: ...et Apply a self adhesive rubber foot A Fig 3 to the bottom at each corner of the air cleaner cabinet The rubber feet will help eliminate vibration and will prevent the possibility of the air cleaner walking across the work or floor surface For operator safety clamp the unit to a work bench or position it securely on sawhorses Fig 3 2 The air cleaner cabinet has convenient lifting handles located o...

Страница 7: ...hen suspending the air cleaner from the ceiling or other overhead support use steel s hooks that are a minimum of 1 4 NOTE Thread all lag hooks at least 1 1 2 into the supporting structural members Never secure the air cleaner hard ware to drywall drop ceiling tile frame or other non structural members Fig 5 Fig 6 Keep a minimum of seven feet between bottom of air cleaner and the floor surface DO ...

Страница 8: ...ig 7B The 50 868 Dust Collector provides a timer that can be set by remote control B Fig 7A When the TIME button B Fig 7A is pressed on the remote control the machine will run for 1 2 hour An LED light will show up on the sensor panel F Fig 7B Pressing the TIME button again will set the machine to run for one hour Notice that the light on the sensor panel has now moved to the 1H location G Fig 7B ...

Страница 9: ... air 4 The inner bag filter is disposable and must be replaced DO NOT try to clean it 5 Reinstall the filters by placing the top of the filter in first and lifting on the bottom to get it into position NOTE The air flow arrow on the outer filter must point inward toward the rear of the air cleaner Location of the air flow arrow is shown at fig 10 Fig 8 A B A ACCESSORIES A complete line of accessor...

Страница 10: ...f purchase of the product within two years and provides Delta with reasonable opportunity to verify the alleged defect by inspection Delta may require that electric motors be returned prepaid to a motor manufacturer s authorized station for inspection and repair or replacement Delta will not be responsible for any asserted defect which has resulted from normal wear misuse abuse or repair or altera...

Страница 11: ...West Southern Avenue Suite 105 Phone 602 437 1200 Fax 602 437 2200 CALIFORNIA Ontario 91761 Los Angeles 3949A East Guasti Road Phone 909 390 5555 Fax 909 390 5554 San Leandro 94577 Oakland 3039 Teagarden Street Phone 510 357 9762 Fax 510 357 7939 COLORADO Arvada 80003 Denver 8175 Sheridan Blvd Unit S Phone 303 487 1809 Fax 303 487 1868 FLORIDA Davie 33314 Miami 4343 South State Rd 7 441 Unit 107 P...

Отзывы: