Delta 40-570 Скачать руководство пользователя страница 5

GROUNDING INSTRUCTIONS

WARNING: THIS TOOL MUST BE GROUNDED WHILE IN USE TO PROTECT THE OPERATOR
FROM ELECTRIC SHOCK. 

1.

All grounded, cord-connected tools:

In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce
the risk of electric shock. This tool is equipped with an electric cord having an equipment-grounding conductor and
a grounding plug. The plug must be plugged into a matching outlet that is properly installed and grounded in
accordance with all local codes and ordinances.

Do not modify the plug provided - if it will not fit the outlet, have the proper outlet installed by a qualified electrician.

Improper connection of the equipment-grounding conductor can result in risk of electric shock. The conductor with
insulation having an outer surface that is green with or without yellow stripes is the equipment-grounding conductor.
If repair or replacement of the electric cord or plug is necessary, do not connect the equipment-grounding conductor
to a live terminal.

Check with a qualified electrician or service personnel if the grounding instructions are not completely understood, or
if in doubt as to whether the tool is properly grounded.

Use only 3-wire extension cords that have 3-prong grounding type plugs and 3-pole receptacles that accept the tool’s
plug.

Repair or replace damaged or worn cord immediately.

2.

Grounded, cord-connected tools intended for use

on a supply circuit having a nominal rating less than 150
volts:

This tool is intended for use on a circuit that has an
outlet that looks like the one illustrated in Fig. 2. The tool
has a grounding plug that looks like the plug illustrated
in Fig. 2. A temporary adapter, which looks like the
adapter illustrated in Fig. 3, may be used to connect this
plug to a 2-pole receptacle as shown in Fig. 3 if a
properly grounded outlet is not available. The temporary
adapter should be used only until a properly grounded
outlet can be installed by a qualified electrician. The
green-colored rigid ear, lug, and the like, extending from
the adapter must be connected to a permanent ground
such as a properly grounded outlet box.

WARNING: IN ALL CASES, MAKE SURE THE

RECEPTACLE IN QUESTION IS PROPERLY
GROUNDED. NEVER REMOVE GROUNDING
PRONG FROM POWER PLUG.

NOTE: In Canada, the use of a temporary adapter
is not permitted by the Canadian Electric Code.

5

Fig. 2

GROUNDED OUTLET BOX

CURRENT

CARRYING

PRONGS

GROUNDING BLADE IS 
LONGEST OF THE 3 BLADES

Fig. 3

GROUNDED OUTLET BOX

GROUNDING

MEANS

ADAPTER

Содержание 40-570

Страница 1: ...ing Feature Model 40 570 PART NO 898602 0010 Copyright 2000 Delta Machinery ESPA OL P GINA 15 To learn more about DELTA MACHINERY visit our website at www deltamachinery com For Parts Service Warranty...

Страница 2: ...they are not safety glasses Also use face or dust mask if cutting operation is dusty These safety glasses must conform to ANSI Z87 1 requirements Note Approved glasses have Z87 printed or stamped on...

Страница 3: ...d the material too fast while cutting Only feed the material fast enough so that the blade will cut 21 NEVER start the Scroll Saw with the stock pressed against the blade 22 WHEN cutting a large workp...

Страница 4: ...on the nameplate Running on low voltage will damage the motor WARNING DO NOT EXPOSE THE TOOL TO RAIN OR OPERATE THE TOOL IN DAMP LOCATIONS MOTOR SPECIFICATIONS Your scroll saw is wired for 110 120 vol...

Страница 5: ...if in doubt as to whether the tool is properly grounded Use only 3 wire extension cords that have 3 prong grounding type plugs and 3 pole receptacles that accept the tool s plug Repair or replace dama...

Страница 6: ...he saw OFF push the switch A down This scroll saw is supplied with variable speed control ranging from 600 to 1650 strokes per minute Turn variable speed control B Fig 5 counterclockwise to reduce spe...

Страница 7: ...standard equipment with your scroll saw and can be used when cutting very small workpieces to give added support to the bottom of the workpiece Cut a slot into the blank and replace the standard inser...

Страница 8: ...5 Push lower blade chuck locking lever F Fig 13 to the rear as shown This will automatically release the blade G from the lower chuck H 6 Insert new blade I into the upper blade holder J making certa...

Страница 9: ...rd and this usually indicates proper tension Finer blades require more tensioning a higher pitched sound while thicker blades require less tension ADJUSTING CLAMPING ACTION OF UPPER AND LOWER BLADE HO...

Страница 10: ...LEVELING THE TABLE 1 Loosen table lock knob as shown in Fig 18 and move the table all the way to the right until angle indicator shown in Fig 19 is on 0 2 Using a square that includes a level check to...

Страница 11: ...25 is provided and can be attached to a shop vacuum system by utilizing the port covered by cap B INSIDE CUTTING A blade threaded through a hole in the workpiece is inside cutting The Delta 16 Scroll...

Страница 12: ...until the optimum cutting speed is obtained LUBRICATION To keep the scroll saw operating at peak efficiency we recommend that a simple maintenance procedure be performed after each 20 hours of use ap...

Страница 13: ...tion it is recommended that only these accessories be used with this unit WARNING Since accessories other than those listed have not been tested with this unit use of such accessories could be hazardo...

Страница 14: ...rom normal wear misuse abuse or repair or alteration made or specifically authorized by anyone other than an authorized Delta Service facility or representative Under no circumstances will Delta be li...