A separate electrical circuit should be used for your machines. This circuit should not be less than #12 wire and should
be protected with a 20 Amp time lag fuse. If an extension cord is used, use only 3-wire extension cords which have 3-
prong grounding type plugs and matching receptacle which will accept the machine’s plug. Before connecting the
machine to the power line, make sure the switch (s) is in the “OFF” position and be sure that the electric current is of
the same characteristics as indicated on the machine. All line connections should make good contact. Running on low
voltage will damage the machine.

DO NOT EXPOSE THE MACHINE TO RAIN OR OPERATE THE MACHINE IN DAMP LOCATIONS.

Fig. A

Fig. B

GROUNDED OUTLET BOX

CURRENT

CARRYING

PRONGS

GROUNDING BLADE
IS LONGEST OF THE 3 BLADES

GROUNDED OUTLET BOX

GROUNDING

MEANS

ADAPTER

2. Grounded, cord-connected machines intended for
use on a supply circuit having a nominal rating less
than 150 volts:

If the machine is intended for use on a circuit that has an
outlet that looks like the one illustrated in Fig. A

,

the

machine will have a grounding plug that looks like the plug
illustrated in Fig. A

A temporary adapter, which looks like

the adapter illustrated in Fig. B, may be used to connect
this plug to a matching 2-conductor receptacle as shown
in Fig. B if a properly grounded outlet is not available. The
temporary adapter should be used only until a properly
grounded outlet can be installed by a qualified electrician.
The green-colored rigid ear, lug, and the like, extending
from the adapter must be connected to a permanent
ground such as a properly grounded outlet box. Whenever
the adapter is used, it must be held in place with a metal
screw.

NOTE: In Canada, the use of a temporary adapter is not
permitted by the Canadian Electric Code.

IN ALL CASES, MAKE CERTAIN THE

R E C E P TA C L E I N Q U E S T I O N I S P R O P E R LY
G R O U N D E D . I F Y O U A R E N O T S U R E H AV E A
QUALIFIED ELECTRICIAN CHECK THE RECEPTACLE.

1. All grounded, cord-connected machines: 

In the event of a malfunction or breakdown, grounding
provides a path of least resistance for electric current to
reduce the risk of electric shock. This machine is
equipped with an electric cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into a matching outlet that is properly installed
and grounded in accordance with all local codes and
ordinances.

Do not modify the plug provided - if it will not fit the outlet,
have the proper outlet installed by a qualified electrician.

Improper connection of the equipment-grounding
conductor can result in risk of electric shock. The
conductor with insulation having an outer surface that is
green with or without yellow stripes is the equipment-
grounding conductor. If repair or replacement of the
electric cord or plug is necessary, do not connect the
equipment-grounding conductor to a live terminal.

Check with a qualified electrician or service personnel if
t h e g r o u n d i n g i n s t r u c t i o n s a r e n o t c o m p l e t e l y
understood, or if in doubt as to whether the machine is
properly grounded.

Use only 3-wire extension cords that have 3-prong
grounding type plugs and matching 3-conductor
receptacles that accept the machine’s plug, as shown in
Fig. A.

Repair or replace damaged or worn cord immediately.

POWER CONNECTIONS

MOTOR SPECIFICATIONS

Your machine is wired for 120 volts, 60 HZ alternating current. Before connecting the machine to the power source,
make sure the switch is in the “OFF” position. 

GROUNDING INSTRUCTIONS

THIS MACHINE MUST BE GROUNDED WHILE IN USE TO PROTECT THE OPERATOR FROM
ELECTRIC SHOCK.

Содержание 36-412

Страница 1: ...A MACHINERY visit our website at www deltamachinery com For Parts Service Warranty or other Assistance please call 1 800 223 7278 In Canada call 1 800 463 3582 12 Dual Bevel Compound Miter Saw Model 3...

Страница 2: ...deltamachinery com Postal Mail Technical Service Manager Delta Machinery 4825 Highway 45 North Jackson TN 38305 Information regarding the safe and proper operation of this tool is available from the f...

Страница 3: ...EMS The symbols below are used to help you recognize this information SAFETY GUIDELINES DEFINITIONS SOME DUST CREATED BY POWER SANDING SAWING GRINDING DRILLING AND OTHER CONSTRUCTION ACTIVITIES contai...

Страница 4: ...injury 12 USE THE RIGHT MACHINE Don t force a machine or an attachment to do a job for which it was not designed Damage to the machine and or injury may result 13 USE RECOMMENDED ACCESSORIES The use o...

Страница 5: ...pward and toward you 17 WHEN USING A SLIDING MITER SAW AS A REGULAR MITER SAW LOCK THE SLIDE MECHANISM IN PLACE If the slide mechanism is not locked the saw can kick back toward you 18 ALLOW THE MOTOR...

Страница 6: ...with a metal screw NOTE In Canada the use of a temporary adapter is not permitted by the Canadian Electric Code IN ALL CASES MAKE CERTAIN THE RECEPTACLE IN QUESTION IS PROPERLY GROUNDED IF YOU ARE NO...

Страница 7: ...pacity 12 dual bevel compound miter saw designed to cut wood and non ferrous metals This machine is supplied with new design features that increase the cutting capacity including built in stops to mak...

Страница 8: ...HE MACHINE FROM THE POWER SOURCE ATTACHING DUST SHROUD 1 Carefully remove the machine from the carton Retain all packing materials until you have inspected and satisfactorily operated the machine 2 Pl...

Страница 9: ...ns ROTATING TABLE FOR MITER CUTTING and ADJUSTING SLIDING FIT BETWEEN MOVABLE TABLE AND BASE FENCE OPERATION The saw is supplied with left and right fence segments A Fig 7 that incorporate a squeeze c...

Страница 10: ...THE BLADE HAS COME TO A COMPLETE STOP THE TORQUE DEVELOPED DURING BRAKING MAY LOOSEN THE ARBOR SCREW THE ARBOR SCREW SHOULD BE CHECKED PERIODICALLY AND TIGHTENED IF NECESSARY LOCKING SWITCH IN THE OF...

Страница 11: ...f you change the angle of cut 1 2 to the left use the left line D in the same manner F F ROTATING TABLE FOR MITER CUTTING Fig 13 Fig 14 DISCONNECT THE MACHINE FROM THE POWER SOURCE Fig 15 To adjust th...

Страница 12: ...on the scale by loosening the screw G adjusting the cursor F and tightening the screw G 5 Place one end of a framing square A Fig 18 against the front of the right fence base B and the other end again...

Страница 13: ...ITIVE STOPS MAKE SURE THAT THE FENCES ARE CLEAR OF THE GUARD AND BLADE BEFORE USING SAW Fig 26 A B Fig 25 A B Fig 28 Fig 27 A A ADJUSTING 0 33 9 AND 45 BEVEL POSITIVE STOPS The bevel adjustment utiliz...

Страница 14: ...he rear of the tool Correct adjustment provides a snug sliding fit between these two parts This adjustment should not be so tight that it restricts the tilting movement of the trunnion when bevel cutt...

Страница 15: ...on the table and hold or clamp it firmly against the fence 4 For best results cut at a slow even cutting rate 5 Never attempt freehand cutting cutting a workpiece that is not held firmly against the f...

Страница 16: ...ng to the blade NEVER APPLY LUBRICANT TO THE BLADE WHILE THE SAW IS RUNNING AUXILIARY FENCE SPACER This machine is supplied with new design features that increase cutting capacity The unit can 1 cross...

Страница 17: ...the table in position NOTE A positive stop is provided to find this angle quickly 2 Place the crown moulding in the nested position between the fence and table with the ceiling edge on the base and t...

Страница 18: ...the 31 62 right miter position and lock the table in position NOTE A positive stop is provided to find this angle quickly 2 Tilt the saw blade to the 33 86 left bevel position and tighten bevel lock h...

Страница 19: ...b site at www deltamachinery com C A D B 2 1 1 2 TROUBLESHOOTING For assistance with your machine visit our website at www deltamachinery com for a list of service centers or call the DELTA Machinery...

Страница 20: ...at the teeth of saw blade are pointing down at the front and attach the outside blade flange G Fig 52 Check to see that the flats on the outside blade flange are engaged with the flats on the arbor sh...

Страница 21: ...ANTY ASSISTANCE All Delta Machines and accessories are manufactured to high quality standards and are serviced by a network of Porter Cable Delta Factory Service Centers and Delta Authorized Service S...

Страница 22: ...Delta may require that electric motors be returned prepaid to a motor manufacturer s authorized station for inspection and repair or replacement Delta will not be responsible for any asserted defect...

Страница 23: ...r Cable Delta m s cercano ARIZONA Tempe 85282 Phoenix 2400 West Southern Avenue Suite 105 Phone 602 437 1200 Fax 602 437 2200 CALIFORNIA Ontario 91761 Los Angeles 3949A East Guasti Road Phone 909 390...

Отзывы: