EXTENSION CORDS

Use proper extension cords. Make sure your extension
cord is in good condition and is a 3-wire extension cord
which has a 3-prong grounding type plug and a 3-pole
receptacle which will accept the tool’s plug. When using
an extension cord, be sure to use one heavy enough to
carry the current of the tool. An undersized cord will
cause a drop in line voltage, resulting in loss of power
and overheating. Fig. 12, shows the correct gauge to use
depending on the cord length. If in doubt, use the next
heavier gauge. The smaller the gauge number, the
heavier the cord.

MINIMUM GAUGE EXTENSION CORD

RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC TOOLS

Ampere       Volts       Total Length of             Gauge of

Rating                         Cord in Feet           Extension Cord

0-6            120             up to 25           

18 AWG

0-6

120             25-50                       16 AWG

0-6            120             50-100                     16 AWG
0-6            120             100-150                   14 AWG
6-10          120             up to 25                   18 AWG
6-10          120             25-50                       16 AWG
6-10          120             50-100                     14 AWG
6-10          120             100-150                   12 AWG      
10-12        120             up to 25                   16 AWG
10-12        120             25-50                       16 AWG
10-12        120             50-100                     14 AWG
10-12        120             100-150                   12 AWG
12-16        120             up to 25                   14 AWG
12-16        120             25-50                       12 AWG       
12-16        120          

GREATER THAN 50 FEET NOT RECOMMENDED

Fig. 12

Fig. 10

Fig. 11

GROUNDED OUTLET BOX

CURRENT

CARRYING

PRONGS

GROUNDING BLADE
IS LONGEST OF THE 3 BLADES

GROUNDED OUTLET BOX

GROUNDING

MEANS

ADAPTER

2. Grounded, cord-connected tools intended for use on
a supply circuit having a nominal rating less than 150
volts:

This tool is intended for use on a normal 120-volt circuit
and has a grounded plug that looks like the plug
illustrated in Fig. 10.

If a properly grounded outlet is not available, a temporary
adapter, shown in Fig. 11, may be used for connecting the
3-prong grounding type plug to a 2-pole receptacle. The
temporary adapter should be used only until a properly
grounded outlet can be installed by a qualified electrician.
The green colored rigid ear, lug, or the like extending from
the adapter must be connected to a permanent ground
such as a properly grounded outlet box cover. Whenever
the adapter is used, it must be held in place with a metal
screw.

NOTE: In Canada, the use of a temporary adapter is
not permitted by the Canadian Electric Code.

WARNING: IN ALL CASES, MAKE CERTAIN

THE RECEPTACLE IN QUESTION IS PROPERLY

GROUNDED. IF YOU ARE NOT SURE HAVE A
CERTIFIED ELECTRICIAN CHECK THE RECEPTACLE.

1 .

A l l g r o u n d e d , c o r d - c o n n e c t e d t o o l s :  

In the event of a malfunction or breakdown, grounding
provides a path of least resistance for electric current to
reduce the risk of electric shock. This tool is equipped
with an electric cord having an equipment-grounding
conductor and a grounding plug. The plug must be
plugged into a matching outlet that is properly installed
and grounded in accordance with all local codes and
ordinances.

Do not modify the plug provided - if it will not fit the outlet,
have the proper outlet installed by a qualified electrician.

Improper connection of the equipment-grounding
conductor can result in risk of electric shock. The
conductor with insulation having an outer surface that is
green with or without yellow stripes is the equipment-
grounding conductor. If repair or replacement of the
electric cord or plug is necessary, do not connect the
equipment-grounding conductor to a live terminal.

Check with a qualified electrician or service personnel if
t h e g ro u n d i n g i n s t r u c t i o n s a re n o t c o m p l e t e l y
understood, or if in doubt as to whether the tool is
properly grounded.

Use only 3-wire extension cords that have 3-prong
grounding type plugs and 3-pole receptacles that accept
the tool’s plug, as shown in Fig. 10.

Repair or replace damaged or worn cord immediately.

Содержание 16" BENCH GRINDERS 23-640

Страница 1: ...5 PART NO 900464 011 Copyright 2001 Delta Machinery ESPA OL P GINA 11 To learn more about DELTA MACHINERY visit our website at www deltamachinery com For Parts Service Warranty or other Assistance ple...

Страница 2: ...eglasses only have impact resistant lenses they are not safety glasses Also use face or dust mask if cutting operation is dusty These safety glasses must conform to ANSI Z87 1 requirements Note Approv...

Страница 3: ...to mount the grinding wheels onto the grinder shaft 15 STAND to one side of the wheel when turning on the power 16 AVOID awkward hand positions where a sudden slip could cause a hand to move into the...

Страница 4: ...HAVE READ AND UNDERSTAND THE ENTIRE INSTRUCTION MANUAL Fig 1 1 Grinder 2 Right side tool rest with V groove 3 Left side tool rest 4 Eye shield 2 5 Eye shield rod 2 6 Eye shield frame 2 7 Eye shield ro...

Страница 5: ...Washer 2 3 4 Flat Washer 4 5 16 18 x 1 2 Hex Head Screw 2 5 16 18 x 5 8 Hex Head Screw 2 3 8 Lock Washer 2 10 24 x 1 2 Round Head Screw 4 1 4 20 Hex Nut 2 10 24 Hex Nut 4 1 4 20 x 3 4 Carriage Head S...

Страница 6: ...of the wheel This is the most practical and safest position for general work Free hand grinding without the use of the tool rest should always be done on the lower quarter of the wheel Fig 4 ASSEMBLI...

Страница 7: ...SOURCE POWER CONNECTIONS A separate electrical circuit should be used for your tools This circuit should not be less than 12 wire and should be protected with a 20 Amp time lag fuse If an extension c...

Страница 8: ...adapter should be used only until a properly grounded outlet can be installed by a qualified electrician The green colored rigid ear lug or the like extending from the adapter must be connected to a p...

Страница 9: ...hole Two aluminum oxide grinding wheels are supplied with your grinder one 36 grit and one 60 grit For best grinding results and to maintain good balance always keep the wheels properly dressed Do not...

Страница 10: ...id to a Delta factory service center or authorized service station with proof of purchase of the product within two years and provides Delta with reasonable opportunity to verify the alleged defect by...