PCK-RGP
CO
Series Power
Connection
Kit
for Roof and Gutter
Delta-Therm Corporation 6711 Sands Road Ste A, Crystal Lake, IL 60014 www.delta-therm.com 800-526-7887
CA_SR_PCK-RGP_
200
2
_DS
II
DESCRIPTION
PCK-RGP allows you to make electrical connections for
all CO Series CBT self-regulating heating cables used
in roof and gutter applications. The kit contains the
necessary materials (except weather-tight junction box)
for one power connection and two end terminations.
A. Heat Shrink Sleeve .75” x 6” (2 x 15cm) (2)
B. Shrink Sleeve .125” x 5.5” (.3 x 14cm) (2)
C. Yellow/Green Shrink Sleeve .25” x 5.5” (1 x 14cm)
D. Ring Connector
E. Ground Screw
F. Heat Shrink Sleeve .5” x 1.5” (1 x 11cm)
G. Heat Shrink Cap .5” x 1.5” (1 x 11cm) (2)
H. Connector Assembly .5”*
I. .5” (1cm)
Sealing
Locknut
Additional compression fittings with 1/2” sealing locknut are available.
A
G
H
I
E
B
C
F
D
Detail 1.
CONNECTING TO POWER
1. Attach connector assembly to the Junction Box through
a .5" (1cm) NPT fitting.
2. Prepare cable per directions.
3. Insert cable through sealing fitting and tighten compo-
nents into place.
4. Connect heating cable leads to power wire leads.
Ground braid cold lead to ground wire or to grounding
screw with ring terminal.
5. Install water tight cover.
Overjacket
Braid
Innerjacket
Conductive Core
Bus Wires (16AWG)
SR CABLE CUTAWAY