![Delta Tau Universal PMAC Lite Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/delta-tau/universal-pmac-lite/universal-pmac-lite_hardware-reference-manual_2478536048.webp)
Universal PMAC Lite
Machine Connections
41
Machine Connections Example
For this configuration, jumpers E85, E87, E88, E89, and E90 are left at the default settings.
ACC-8D or ACC-8P
#1
Pin #
#2
Pin #
#3
Pin #
#4
Pin #
SYMBOL
53 54 39 40
-LIMn
55
56 41 42 HMFLn
51 52 37 38
+LIMn
58
58
58
58
AGND
1
2
1
2
+5V
3
4
3
4
GND
17 18 5 6
CHCn
19
20
7
8
CHCn/
21
22
9
10
CHBn
23 24 11 12
CHBn/
25 26 13 14
CHAn
27 28 15 16
CHAn/
43 44 29 30
DACn
45
46
31
32
DACn/
47 48 33 34 AENAn/DIRn
49
50
35
36
FAULTn
58
58
58
58
AGND
58
AGND
59
A+15V/OPT+V
60
A-15V
PMAC installed in a desktop PC
Motor
Encoder
Load
Flags
±15 Volts Power Supply
Amplifier
ACC-8D