2
Connect the GP1
2.1. Mount GP1 on post
Open the GP1 cover and attach to the
mounting plate using the 4 screws provided.
Then fix the mounting plate to a suitable post
either using cable ties, tape or U-bolts
(provided).
2.2. Connect cables to GP1
Pass the cable from the SM300 through the cable gland and connect to Channel 1
as shown (order for channel 1 is red, grey, white, black, green and blue):
Connect the cable for controlling the solenoid valve to the relay as shown (note the
colours of your cable will likely be different but the orientation of the connection is
unimportant).
Don’t connect the other end to the solenoid valve at this stage.
Tighten the cable glands, replace the GP1 cover, secure all cables to the post and
tape carefully over any cable runs in walkways.
Refer to the
GP1 Quick Start Guide
if you want to connect the
SM300 temperature sensor or need more detailed instructions.