Delta Regis DRFF-208 Скачать руководство пользователя страница 15

DRFF-208R / DRFF-512R / DRFF-519R Screw Feeder

Operation and Setup Manual

www.deltaregis.com

15

Problem

Reason

Solution

Gate opening(s) too 

tight

Adjust the gates (0.2mm 

gap)

Height of screw head 

guide plate too low

Adjust the height of the 

guide plate (see page 5)

Vibration motor speed 

no good at current 

setting

Adjust Program 05 until 

screws feed smoothly

No signal output (if 

equipped)

Relay PCB damaged or 

wire disconnected

1. Use a voltmeter set to 

ohms. Circuit is open when 

no screw present, circuit is 

closed when screw present

2. Reconnect wire to PLC 

and/or relay PCB

Main PCB damaged 

or relay wire harness 

disconnected

1. Reconnect wire harness 

to main PCB

2. Return for service

Buzzer on, 

indication LED 

steady on

Main PCB damaged

Return for service

NOTE:

If any of the above error codes appear on the LCD, please turn off 

the unit immediately, unplug the power source and return the unit 

for service.

Continued use in a fault state will void your warranty.

Содержание DRFF-208

Страница 1: ...ons in this manual before using a DRFF screw feeder If you have any questions or concerns please contact us at Delta Regis Tools Inc Ph 1 772 465 4302 7370 Commercial Circle Fx 1 772 465 4368 Fort Pie...

Страница 2: ...crew feeder The screw feeder rail must be kept free from oil grease dust or any other contaminates Do not place you hand or any foreign objects into the screw hopper when the unit is running In the ev...

Страница 3: ...ed Accessories This machine has been set up according to the sample fasteners and ortechnicaldrawingyouhadprovidedusduringyourpurchase Iffine tuning is required please follow the instructions starting...

Страница 4: ...deltaregis com 4 Product Overview 1 Rail Gates 2 Power Switch 3 Screw Present Error LED 4 Programming Key Pad w LCD 5 DC Receptacle 6 Grounding Lug ESD Applications 7 I O Wires 1 1 2 3 4 5 6 2 3 4 un...

Страница 5: ...is com 5 User Adjustments Screw Guide Plate 1 Locate and loosen highlighted screws using a 2mm hex key 2 Using the included shims insert under the screw head guide press down on the plate and tighten...

Страница 6: ...nto the rail assembly Tilt the screw feeder forward ensure the screws can smoothly pass under the guide plate NOTE When adjusting the screw guide plate the screws from step 1 must be fully tightened t...

Страница 7: ...t the infrared openings so only half of the opening is exposed tighten screws from step 1 NOTE Only half of the infrared opening can be exposed If the screw cannot be detected you can make further adj...

Страница 8: ...chute to align with the center of the rail NOTE The chute must not come into contact with the rail A 0 8 1 0mm gap must be maintained For certain screws it may be necessary to move the chute to the e...

Страница 9: ...veral screws into the rail under the brush Manually sweep the brush across the screw heads Adjust the brush so slightly touches the screw heads Re tighten the screws from step 1 NOTE The brush holder...

Страница 10: ...Remove the hopper cover Check for debris or foreign objects Fill the hopper with screws leaving a minimum of 2 mm space under the rail for thread lengths up to 5mm 4mm space for thread lengths over 5...

Страница 11: ...the OK key to enter the value under this program Currently the first two digits of the display are solid and the last two digits are flashing Short press the UP or DN key to set the program value 3 A...

Страница 12: ...am Value 01 20 1 second per unit 05 Vibration Motor Speed Set the operating speed of the vibration motor Program Value 01 20 01 min 20 max 06 Drum Brush Motor Shutdown Delay Set the delay time for the...

Страница 13: ...m 12 is enabled the vibration and drum brush motors will not run The turntable will rotate at minimum speed for several cycles before stopping Once the turntable has stopped adjust the infrared sensor...

Страница 14: ...es are properly closed and remove all screws from inside the machine Infrared sensors misaligned Adjust the alignment of the sensors see page 7 14 Infrared sensors blocked Clear obstruction and or cle...

Страница 15: ...ipped Relay PCB damaged or wire disconnected 1 Use a voltmeter set to ohms Circuit is open when no screw present circuit is closed when screw present 2 Reconnect wire to PLC and or relay PCB Main PCB...

Страница 16: ...e immediately Rail cleaning maintenance Using a lint free swab dipped in alcohol clean the inner rail surfaces clean the rail s sliding surface very well as to remove any debris or oil Cleaning and ma...

Страница 17: ...in material and workmanship This warranty does not cover damage due to transportation abuse misuse modification or improper service Our sole remedy is to repair or replace at our discretion any unit f...

Страница 18: ...ntact PLC IN Note When a screw is present the signal is output through photo couplers to a relay circuit Connection Red wire is connected to PLC positive power terminal black wire is connected to PLC...

Страница 19: ...ame Delta Regis Applicable Models DRFF 312R DRFF 519 DRFF 519R DRFF 519E The undersigned hereby declares on behalf of Delta Regis Tools Inc that the product designated in this declara on is in conform...

Страница 20: ...Feeder Trade Name Delta Regis Applicable Models DRFF 208R DRFF 208 The undersigned hereby declares on behalf of Delta Regis Tools Inc that the product designated in this declara on is in conformity w...

Отзывы: