Step 4 – Update the charger 

(See screen 

image below) 

 
Icon 

Action 

 

To delete a charge algorithm from 
the charger: 

Select the algorithm(s) you want to 
remove from the Charger’s list of 
Algorithms Present, and click the red 
“X” icon.  The algorithm(s) will be 
removed from the charger. 
 

 

To add a charge algorithm to the 
charger: 

Select the algorithm(s) you want to 
add from the Computer’s list of 
Battery Charge Algorithms, and click 
the right arrow icon.  The algorithm(s) 
will be added to the charger.  It will 
take around 1-2 seconds to load. 

-or- 

To upgrade the software of the 

charger: 

Select the version of software you 
want to add from the Computer’s list 
of Charger Software Versions, and 
click the right arrow icon.  It will take 
around 45 seconds to load. 

 

 

 

 

 

 

To selecting a different charge 
algorithm for charging 

Select which algorithm you would like 
to set as the default charge algorithm 
from the Charger’s list of Algorithms 
Present, then click the up arrow icon.  
The default algorithm will be updated. 

 

 

 

Enjoy! 

 
 

 
 
 
 
 

Copyright © 2007 
All rights reserved 
Delta-Q Technologies Corp. 

 

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Содержание QuiQ 912-24 series

Страница 1: ...time will vary by how large and how depleted the battery pack is the input voltage the higher the better and ambient temperatures the lower the better If the input AC voltage is low below 104VAC then...

Страница 2: ...e and the status display must be visible to the user 2 Mounting Procedure Mount the charger by the mounting plate using appropriate fasteners i e 1 4 or M6 with locking hardware For UL2202 compliance...

Страница 3: ...rrent output reduced Provide better airflow to the charger Try to move the charger to a cooler location Confirm that dirt or mud is not blocking the cooling fins of the charger Clean the charger Rinse...

Страница 4: ...ed time This could occur if the battery is of larger capacity than the algorithm is intended for In unusual cases it could mean charger output is reduced due to high ambient temperature It can also oc...

Страница 5: ...has started charging normally be sure to make a note of it Try to clear the fault by unplugging AC power waiting 30 seconds and reconnecting the AC Check all battery connections Look for a high resis...

Страница 6: ...for this problem is incorrect charge algorithm setting and or high ambient temperatures Confirm that the battery pack is not too small usually 50Ah Confirm that the nominal battery voltage matches the...

Страница 7: ...ge algorithm to correct setting for batteries No Connect charger to batteries and plug charger into AC Yes Does the Red LED indicate a fault Is the interlock functioning if used Note that the interloc...

Страница 8: ...ee above you are ready to connect your QuiQ charger to the computer with the QuiQ USB Interface Module Step 1 Disconnect AC power from QuiQ charger Step 2 Disconnect QuiQ charger from batteries and co...

Страница 9: ...erify communications with the charger See screen image below The No Charger Detected message indicates that the QuiQ Programmer is unable to communicate with your charger This could be due to one of t...

Страница 10: ...charger It will take around 1 2 seconds to load or To upgrade the software of the charger Select the version of software you want to add from the Computer s list of Charger Software Versions and click...