The communication between the instrument and the PC or between the instrument and the
printer works only if the baud rate of the instrument and the one belonging to the connected
device (computer or printer) are the same.
Example of printing of a logging section, obtained with
HD40.1
printer
NOTES
Log number: 1
Number of logging sections
========================
ISO 7243 WBGT Index
Reference rules
========================
Model HD32.2 WBGT Index
Instrument model
Firm.Ver.=01.00
Version of the instrument firmware
Firm.Date=2008/12/05
Date of the instrument firmware
SN=12345678
Instrument serial number
ID=0000000000000000
Identification code
------------------------
Probe ch.1 description
Description of the probe connected to the inlet 1
Type: Pt100
Data cal.:2008/10/01
Serial N.:08109450
------------------------
Probe ch.2 description
Description of the probe connected to the inlet 2
Type: Pt100 Tg 50
Data cal.:2008/10/01
Serial N.:08109452
------------------------
Probe ch.3 description
Description of the probe connected to the inlet 3
Type: Pt100 Tw
Data cal.:2008/10/01
Serial N.:08109454
========================
From=2008/11/21 15:00:00
Logging start day and hour
To =2008/11/21 16:30:00
Logging end day and hour
Tot. rec.= 000360
Number of samples acquired by the instrument
** max value **
Maximum value of the acquired data
Tnw 21.2 °C
Maximum temperature of wet bulb with natural ventilation
Maximum temperature of globe thermometer
Tg 24.9 °C
Maximum temperature of wet bulb
Ta 31.3 °C
Maximum WBGT in absence of direct solar irradiation
WBGT (i) 22.3 °C
Maximum WBGT in presence of direct solar irradiation
WBGT (o) 23.0 °C
** min value **
Minimum value of the acquired data
Tnw 21.0 °C
Minimum temperature of wet bulb with natural ventilation
Tg 24.9 °C
Minimum temperature of globe thermometer
Ta 23.5 °C
Minimum temperature of wet bulb
WBGT (i) 22.2 °C
Minimum WBGT in absence of direct solar irradiation
WBGT (o) 22.6 °C
Minimum WBGT in presence of direct solar irradiation
** avg value **
Medium value of the acquired data
Tnw 21.1 °C
Medium temperature of wet bulb with natural ventilation
Tg 24.9 °C
Medium temperature of globe thermometer
Ta 30.3 °C
Medium temperature of wet bulb
WBGT (i) 22.3 °C
Medium WBGT in absence of direct solar irradiation
WBGT (o) 22.8 °C
Medium WBGT in presence of direct solar irradiation
========================
Notes:
========================
NOTE: The printing of a logging section on HD40.1 printer contains only the statistic data. To
visualize all the acquired data, it’s necessary to download the data using DeltaLog10 software.
Содержание HD32.2
Страница 2: ...2 WBGT Wet Bulb Globe Temperature Meter HD32 2...
Страница 39: ...39 12 PRINTING OF THE MEASUREMENT REPORT Norm ISO 7243 Norm ISO 7243...
Страница 40: ...40 Warm Environments Norm ISO 7243...
Страница 41: ...41 Warm Environments Norm ISO 7243 Norm ISO 7243...
Страница 42: ...42 Warm Environments Norm ISO 7243...
Страница 43: ...43 Warm Environments Norm ISO 7243...
Страница 44: ...44 Warm Environments Norm ISO 7243...
Страница 49: ...49 NOTES...
Страница 50: ...50 NOTES...