![DELTA M microtuf FS3200 Series Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/delta-m/microtuf-fs3200-series/microtuf-fs3200-series_operation-and-maintenance-manual_2478262013.webp)
DELTA M Corporation
3242-OM-04 3/27/02
9
3.0
INSTALLATION
3.1 Mechanical
Installation
The standard microtuf
®
Switch has a .75 inch (19.05mm) MNPT mount designed for easy
installation through a threaded port. Optional configurations include .5” (12.7mm) or 1.0”
(25.4mm) MNPT and flange mounts. Conduit is recommended for all wiring to the switch.
*IMPORTANT*
USE A 1 1/8 INCH (28.575mm) OPEN-END WRENCH TO TIGHTEN AT THE
HEX FLATS OF THE MNPT OF A STANDARD SWITCH. (IF YOU HAVE A
NON-STANDARD SWITCH AN ALTERNATE SIZE WRENCH MAY BE
REQUIRED). DO NOT USE THE INSTRUMENT HEAD TO TIGHTEN THE
SWITCH TO THE MOUNTING PORT. ROTATION OF THE INSTRUMENT
HEAD WITH RESPECT TO THE SENSOR BODY CAN CAUSE INTERNAL
WIRING DAMAGE.
*IMPORTANT*
THE SWITCH BODY MUST BE ORIENTED TO HAVE THE TWIN SENSORS
PROPERLY ORIENTED. DUE TO THE PIPE THREAD MOUNTING, IT MAY
BE NECESSARY TO MAKE A TRIAL FIT, ADD OR REMOVE TEFLON
TAPE OR OTHER PIPE THREAD SEALANT, AND REINSTALL TO
ACHIEVE A SATISFACTORY SEAL WITH THE SENSORS PROPERLY
ORIENTED. PROPER ORIENTATION IS MARKED ON THE SWITCH BODY
FOR REFERENCE. SEE FIGURE 5.0 FOR DETAILS.