Delta Heat Service (562) 263-3600 | 7
LEAK TEST
CAUTION BEFORE TESTING
•
Finding and/or fixing a gas leak is NOT a “DO-IT-YOURSELF” procedure.
• NEVER USE THE TEPPANYAKI GRIDDLE WITHOUT FIRST LEAK TESTING THE GAS CON-
NECTIONS.
• WARNING: DO NOT USE OPEN FLAME TO CHECK FOR LEAKS. USE OF AN OPEN FLAME
COULD RESULT IN A FIRE, EXPLOSION, BODILY HARM OR DEATH.
• DO NOT SMOKE WHILE PERFORMING THE LEAK TEST!
•
To prevent fire or explosion hazard, DO NOT use or permit sources of ignition in the area while
performing a leak test. Perform leak test outdoors only.
•
Check to ensure that flexible hoses do not have any cuts and wear that may affect the safety
before each use. Only the factory supplied hose and regulator must be used. Use only replace-
ment regulator and hose assemblies specified by DELTA HEAT.
LEAK TEST
1.
Prepare a leak testing solution of sudsy water by mixing in a spray bottle with half liquid soap
and half water.
2.
Confirm that all control knobs are in the OFF position.
3. Turn the main gas valve supply ON.
4.
Apply leak testing solution by spraying on the pipe joints, fittings, and hose.
5. A gas leak is detected if;
a. there is a faint gas smell and/or…
b. growing bubbles appear on any of the connection points and/or hose, DO NOT attempt to
ignite the Teppanyaki Griddle and IMMEDIATELY turn off the gas supply valve.
6.
When there is a gas leak, call a qualified service technician. DO NOT use the Teppanyaki
Griddle until the leak is corrected.
LEAK TEST
LEAK TEST
TYPICAL BOTTLE LP GAS
HOOK-UP
TYPICAL NATURAL GAS
HOOK-UP
Содержание DHTG32
Страница 1: ...DELTA HEAT TEPPANYAKI GRIDDLE INSTALLATION USE CARE MANUAL P N 17634A 02 21 MODELS DHTG32...
Страница 2: ......