Quick installation guide for RPI H3 inverters
Planning the installation
5
>30 cm
>30 cm
>30 cm
>50 cm
>50 cm
Ź
Ensure adequate air circulation. Hot air must be able
WRGLVVLSDWHXSZDUG.HHSVXI¿FLHQWVSDFHDURXQG
each inverter.
Ź
Do not install inverters directly above one another.
Otherwise, the upper inverter is warmed up by the
lower one.
Ź
Consider the
operating temperature range
(see sec-
tion “Technical Data”).
When the operating temperature range is exceeded,
the solar inverter reduces the amount of power gener-
ated.
Ambient temperature and air circulation
Outdoor installations
Ź
The solar inverter has protection
degree IP65 and can be installed
indoors or in protected outdoor
areas (that means outdoor but
protected by a roof against direct
sun, rain or snow).
Ź
Mount the solar inverter vertically.
Where to mount the inverter
??
??
ᅛ
ᅟ
ᅟ
Ź
Mount the solar inverter so that the
LEDs and display can be easily seen
and that the buttons can be operated.
Make sure the reading angle and instal-
ODWLRQKHLJKWDUHVXI¿FLHQW
Ź
Always use the mounting plate
supplied with the inverter.
Ź
Check that the wall is capable of
bearing the heavy weight of the
inverter.
Ź
Use dowels and screws that are
suitable for the wall material and
the heavy weight.
Ź
Mount the inverter on a vibration-
free wall to avoid disruptive
vibrations.
Ź 0RXQWWKHLQYHUWHURQDÀDWZDOO
only. Brick walls can cause prob-
lems if they are too bumpy.
Ź
Possible noise emissions can be
disruptive when the inverter is
used in living areas or in buildings
with animals. Therefore, choose
your installation location carefully.
Mounting orientation