background image

http://www.delta.com.tw/industrialautomation/

 

5011658300-MNE0

2007-01-23

 

 

Digital I/O Extension Unit   
(Pin Headed)

 

Instruction Sheet 

 

 

Warning 

3

 

Please read this instruction sheet carefully before use.

 

 

3

 

DVP-Slim is an OPEN-TYPE device and therefore should be installed in an enclosure free of airborne dust, humidity, 
electri shock and vibration. The enclosure should prevent non-maintenance staff from operating the device (e.g. key or 
specific tools are required to open the enclosure) in case danger and damage on the device may occur.

 

 

3

 

DO NOT connect input AC power supply to any of the I/O terminals; otherwise serious damage may occur. Check all the 
wiring again before switching on the power. DO NOT touch any terminal when the power is switched on. 

 

X

 

Introduction

 

1.1  Model Explanation & Peripherals 

Thank you for choosing Delta DVP-Slim series programmable logic controller. DVP-Slim series pin-headed digital I/O 

extension unit offers 32 points. For DVP-SS/SA/SX/SC series MPU, the maximum digital I/O extension points (including 

the MPU) can reach 128 points. For SV series MPU, the maximum digial I/O extension points (including the MPU) can 

reach 256 points. In addition, maximum 8 additional special modules (AD/DA/PT/TC/XA/PU) can be extended to 

DVP-Slim series extension unit.   

 

Nameplate Explanation 

VX.XXAX

24Vdc  1W   
0.1A(24VDC)POINT

M A D E    I N    X X X X X

32SN11TNT7020001

Delta PLC model name

Power input spec.

Output point module spec.

Barcode & serial No.

Version

 

 

Model Name 

 

Serial No. 

 

 

 Input point extension unit

 

 Output point extension unit

M:
N:

DVP series

Points (32 for output)

Module type

TN:

N:

 NPN transistor

 No output module

DC power input

 

 

Production No.

Model name

Production week
Production year (2007)
Production plant

 

1.2 Product 

Profile

 

 

Unit: mm 

 

c

 

POWER, L.V (low voltage) indicator 

h

 

Extension unit positioning hole 

d

 

Model name 

i

 

Nameplate 

e

 

Extension unit fixing clip 

j

 

Extension unit fixing clip 

f

 

I/O terminals 

k

 

DIN rail (35mm) 

g

 

DIN rail clip 

l

 

Connection port for extension unit 

 

1.3 Model 

Information

 

Input 

Output 

Model name 

Power 
supply  Points 

Type 

Points 

Type 

Dimension 

(mm) 

Outline 

DVP32SM11N 

32 

DC Type 

 Sink/Source 

0 N/A 

DVP32SN11TN 

24V DC 

0 N/A 32 

(NPN) 

Transistor  

25.2  90  60 

 

 

Y

 

Specifications

 

2.1 Electrical 

Specifications 

                              Model   
 Item 

DVP32SM11N

 

DVP32SN11TN

 

Power supply voltage 

24V DC (-15% ~ 20%) (with DC input polarity reverse protection) 

Motion specification 

Within 5ms of the momentary power loss, the device will keep on operating. 

Power consumption 

1W 

1.5W 

Insulation resistance 

5 M

 (all I/O point-to-ground: 500V DC) 

Noise immunity 

ESD (IEC 61131-2, IEC 61000-4-2): 8KV Air Discharge   
EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2KV, Digital I/O: 1KV,   
Analog & Communication I/O: 1KV 
Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV 
RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m 

Earth 

The diameter of grounding wire shall not be less than that of L, N terminal of the 
power. (When many PLCs are in use at the same time, please make sure every PLC 
is properly grounded.) 

Operation/storage 
environment 

Operation: 0ºC ~ 55ºC (temperature); 50 ~ 95% (humidity); pollution degree 2 
Storage: -40ºC ~ 70ºC (temperature); 5 ~ 95% (humidity) 

Shock/vibration 
immunity 

International standards: IEC1131-2, IEC 68-2-6 (TEST Fc)/IEC1131-2 & IEC 68-2-27 
(TEST Ea) 

Weight (g) 

70g 

70g 

2.2  I/O Point Specifications 

Input Point 

Input type 

DC (SINK or SOURCE) 

Input current 

24VDC, 5mA 

Active level 

Off 

Æ

 On    more than 16V DC 

On 

Æ

 Off    less than 14.4V DC 

Response time 

Approx. 10ms, 0 ~ 15ms adjustable from D1020, D1021 

Circuit isolation / 
operation instruction 

By photocoupler / LED On 

 

Output Point 

Output type 

Transistor – T (NPN) 

Current specification 

0.1A/point 

Voltage specification 

5 ~ 24 VDC 

Maximum load 

55ºC/1A (COM), 25ºC/2.4A (COM) 

Response time 

Off 

Æ

 On    less than 0.1ms 

On 

Æ

 Off    less than 0.3ms 

 

Z

 

Installation & Wiring

 

3.1  Terminals of Digital I/O Extension Unit 

DVP32SM11N 

DVP32SN11TN 

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

X21
X23
X25
X27
X31
X33
X35
X37
S/S
NC

X1
X3
X5
X7
X11
X13
X15
X17
S/S
NC

X20
X22
X24
X26
X30
X32
X34
X36

S/S

NC

X0
X2
X4
X6

X10
X12
X14
X16
S/S

NC

DVP32SM

 

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

Y21
Y23
Y25
Y27
Y31
Y33
Y35
Y37
GND
+24V

Y1
Y3
Y5
Y7
Y11
Y13
Y15
Y17
GND
+24V

Y20
Y22
Y24
Y26
Y30
Y32
Y34
Y36

GND

+24V

Y0
Y2
Y4
Y6

Y10
Y12
Y14
Y16

GND

+24V

DVP32SN

 

ƒ

 

DVP32SN currently only offers TN (NPN) transistor output. 

ƒ

 

Please be aware of the following PIN wiring methods for DVP32SN to prevent burn-down of the extension unit. 

1.  PIN19, PIN20, PIN39 and PIN40 can only connected to +24V DC. The 4 points have already been designed as 

short-circuit within the extension unit; therefore only 1 of the points needs to be wired. 

2.  PIN17, PIN18, PIN37 and PIN38 can only connected to GND. The 4 points have already been designed as 

short-circuit within the extension unit; therefore only 1 of the points needs to be wired. 

 

3.2 Connection 

Step 1:

 Screw open the side cover of the extension 

unit and you will see the connection port. 

 

Step 2:

 Lift the fixing clip by the screwdriver. 

 

Step 3:

 Adjust the positioning hole of the MPU and 

the extension unit and meet the connection port on 

the MPU with the extension unit to tightly connect 

the two. 

 

Step 4:

 Fasten the fixing clip on the extension unit 

to complete the connection. 

 

3.3  Installation & Wiring 

Install the PLC in an enclosure with sufficient space around it to allow heat dissipation as shown in the figure below.

 

DVP

MPU

D

D

D

D

D > 50mm

 

 

Отзывы: