Delta Electronics E48SB12020 Скачать руководство пользователя страница 5

DS_E48SB12020_05222008 
 

 
 

ELECTRICAL CHARACTERISTICS CURVES 

Figure 9: 

Output voltage response to step-change in load 

current (50%-75%-50% of Io, max; di/dt = 0.1A/µs). Load cap: 
10µF, tantalum capacitor and 1µF ceramic capacitor. Top Trace: 
Vout (200mV/div, 200us/div), Bottom Trace: Iout (10A/div). 
Scope measurement should be made using a BNC cable 
(length shorter than 20 inches). Position the load between 51 
mm to 76 mm (2 inches to 3 inches) from the module.

 

 Figure 

10: 

Output voltage response to step-change in load 

current (50%-75%-50% of Io,max; di/dt=1A/µs). Load cap:
10uF, tantalum capacitor and 1µF ceramic capacitor. Top Trace: 
Vout (200mV/div, 200us/div), Bottom Trace: Iout (10A/div).
Scope measurement should be made using a BNC cable 
(length shorter than 20 inches). Position the load between 51 
mm to 76 mm (2 inches to 3 inches) from the module.

 

 

 

Figure 11: 

Test set-up diagram showing measurement points 

for Input

 

Terminal Ripple Current and Input Reflected Ripple 

Current. 
Note: Measured input reflected-ripple current with a simulated 
source Inductance (L

TEST

) of 12 

μ

H. Capacitor Cs offset 

possible battery impedance. Measure current as shown below

 

 

 

 

Содержание E48SB12020

Страница 1: ...us Converter DC DC Power Modules 48Vin 12V 20A out Delta Electronics Inc a world leader in power systems technology and manufacturing has introduced the E48SB eighth brick sized 240W bus converter int...

Страница 2: ...ak to Peak Full Load 1 F ceramic 10 F tantalum 80 100 mV RMS Full Load 1 F ceramic 10 F tantalum 25 40 mV Output current range when Vin below 44V 0 22 3 A Operating Output Power Range Output power ran...

Страница 3: ...at 25 C Figure 2 Power loss vs load current for minimum nominal and maximum input voltage at 25 C 2 4 6 8 10 12 14 0 3 6 9 12 15 18 21 24 27 Output Current A Output Voltage V 38Vin 48Vin 55Vin 17 00...

Страница 4: ...OFF input 2V div Figure 6 Turn on transient at zero load current 5 ms div Top Trace Vout 5V div Bottom Trace ON OFF input 2V div For Positive Remote On Off Logic Figure 7 Turn on transient at full ra...

Страница 5: ...ltage response to step change in load current 50 75 50 of Io max di dt 1A s Load cap 10uF tantalum capacitor and 1 F ceramic capacitor Top Trace Vout 200mV div 200us div Bottom Trace Iout 10A div Scop...

Страница 6: ...minal input voltage and rated load current 20 mA div 20us div Vo Vo 10u 1u Copper Strip SCOPE RESISTIVE LOAD Figure 14 Output voltage noise and ripple measurement test setup Figure 15 Output voltage r...

Страница 7: ...pliance with CISPR 22 class B which is shown as below Vin 48V Io 20A average mode Soldering and Cleaning Considerations Post solder cleaning is usually the final board assembly process before the boar...

Страница 8: ...on the module can be either negative or positive logic Negative logic turns the module on during logic low and off during logic high Positive logic turns the modules on during logic high and off durin...

Страница 9: ...ace between the neighboring PWB and the top of the power module is constantly kept at 6 35mm 0 25 Note Wind Tunnel Test Setup Figure Dimensions are in millimeters and Inches 12 7 0 5 MODULE AIR FLOW 5...

Страница 10: ...1 2 3 4 5 Vin ON OFF Vin Vout Vout Positive input voltage Remote ON OFF Negative input voltage Negative output voltage Positive output voltage Pin Specification Pins 1 3 1 0mm 0 040 diameter Pins 4 5...

Страница 11: ...ng system above or contact your local sales office CONTACT www delta com tw dcdc USA Telephone East Coast 888 335 8201 West Coast 888 335 8208 Fax 978 656 3964 Email DCDC delta corp com Europe Phone 4...

Отзывы: