Test 

1)  Turn on the fan. 
2)  Adjust the input voltage to the desired operating point. 
3)  Set the electronic or resistive load at 50% of maximum load. 
4)  Change channel 1 to scope probe and measure across the 

dynamic

R

5)  Set the switch SW2 to the converter ON. 
6)  Set channel 2 on the oscilloscope to be AC coupled and to 50mV/Div and for 5mS/Div. Set

the trigger to auto and adjust the trigger point at a negative going pulse for step load
change from 50% to 100% of Io or adjust the trigger point at positive going pulse for step
load change from 100% to 50% (Please refer to data sheet) 

7) Measure the Peak-to-Peak deviation and capture the waveform as required.  

 

 

8.3.2 Turn-On Response Time. 

 

Turn-On Response Time is defined as the time it takes for the output to rise to within

 

90% of

its final value from the time when the converter is enabled. The rise time is deliberately made
slower to reduce the inrush current and to eliminate any overshoot in the output voltage.
These test functions have two categories.  
 
1.)  Turn on the module by using the External switch to control input voltage. 
2.)  Turn on module by using the Enable on/off. 

 

Note: 

There is some difference in the performance of each mode - please refer to the data

sheet for the detailed information.

 

 

 

Test  (Turn on the module by using the external switch)

 

1)  Turn on the fan. 
2)  Turn on the input power supply and set it to the desired operating point. 
3)  Set channel 1 on the oscilloscope to be DC coupled and to the appropriate range for the

input voltage.  

4)  Connect a coaxial cable from channel 1 to BNC1 on the Evaluation Board. 
5)  Set channel 2 on the oscilloscope to be DC coupled and to the appropriate range for the

output voltage. 

6)  Connect a coaxial cable from channel 2 to BNC2 on the Evaluation Board.  
7)  Set the Time base to 2mS/Div  
8)  Set the Trigger for a one-time event and set the Trigger level at approximately 2V (rising)

or suitable trigger point (referring to data sheet) on channel 2. 

9) Enable the external on/off switch to supply power and use the cursor V Bars for

measurement of the delay time, and then record the waveform on the oscilloscope. 

 

Test  (Turn on the module by using the Enable on/off)

 

1.  Turn on the fan. 
2.  Turn on the input power supply and set it to the desired operating point. 
3.  Set channel 1 on the oscilloscope to be DC coupled and to 1V/division. (Please refer to

data sheet).  

17 

Содержание DNL Series

Страница 1: ...dels possess a myriad of standard protection features This document guides the user through the evaluation procedures to qualify a POL module The data shown in this Evaluation Procedure is for the SMT...

Страница 2: ...3 3 Digital multi meters one with 20A range and ideally all with 4 1 2 digit resolution DVM1 DVM2 and DVM3 Zentech 2041 or equivalent 3 4 An electronic load Chroma 63030 or equivalent 300W approximate...

Страница 3: ...BNC cable length less than 20 inches 500mm from BNC1 of the Evaluation Board to Channel 1 of the oscilloscope See Item 3 2 This cable is used to measure the input voltage between SVIN and SGND 4 6 Con...

Страница 4: ...termine that the correct module is being evaluated Note DNM04S0A0S10P A would denote the SMT package while DNM04S0A0R10P A would denote the SIP package This Evaluation Board is for use with SMT packag...

Страница 5: ...e converter requires a margin trim up push the SW3_4 to ON position Please refer to the SW3 Function table SW3 Function table Subdivide switch No Function SW3_1 Voltage trim up SW3_2 Voltage trim down...

Страница 6: ...e Item 7 1 5 4 Test the input under voltage function while observing DVM2 DVM3 and channel 1 of the oscilloscope Increase the input voltage until the output of the converter reaches the appropriate va...

Страница 7: ...voltage and temperature remain constant Test 1 Turn on the fan 2 Set the input voltage to the desired operating level while monitoring DVM2 3 Set the switch SW2 to the converter ON 4 Adjust the output...

Страница 8: ...program the output voltage of the DNL04S module to 1 8Vdc below is the calculation of Rtrim 15004 5110 7525 0 8 1 21070 set R The table 1 provides the Rset value required for some standard output and...

Страница 9: ...nge please refer to the data sheet for the detailed specification 2 Output Voltage Set Point Adjustment by external voltage source For DNM and DNL series trim to Vo set using an external voltage sourc...

Страница 10: ...t pin for Trim down The Rmargin up is for trim up and Rmargin down is for trim down Please refer to the data sheet and Evaluation Board Schematic for the detailed information A software tool for volta...

Страница 11: ...equential start up is implemented by connecting the power good signal PWRGD pin of PS1 to the TRACK pin of PS2 with a resistor capacitor RC circuit The power up and down that waveforms in Figures 4 an...

Страница 12: ...ne the tracking method that is implemented To simplify the tracking design set the initial value of R2 equal to 20K at internal circuit and adjust the resistor R1 for different tracking method Figure...

Страница 13: ...PS2 Voset PS2 3 3V R1 is calculated as follows K K R 75 55 20 32 1 32 1 7 1 3 3 1 Figure 7 Ratio metric tracking Power up Figure 8 Ratio metric tracking Power down For Ratio Metric applications that n...

Страница 14: ...he objective is to minimize the voltage difference between the power supply outputs during power up and down The waveforms of power up and down are showed in Figures 13 and 14 For type A DNXXX0A0XXXX...

Страница 15: ...start up when VoPS2 tracks the VoPS1 only for type C R1 R2 TRACK VoPS1 PS2 VoPS2 PS1 Vin Vin ENABLE ENABLE To Tracking circuit 20K 30 1K Figure 12 PS1 and PS2 track output voltage Simultaneous start...

Страница 16: ...bsolute maximum voltage cannot over the Vin 5 For type A When Tracking is unused put R1 equal to 1K and connect TRACK pin to Vcc For type C When Tracking is unused put R1 equal to 30 1K and connect TR...

Страница 17: ...ge 2 Turn on module by using the Enable on off Note There is some difference in the performance of each mode please refer to the data sheet for the detailed information Test Turn on the module by usin...

Страница 18: ...8 4 Thermal Characteristic 8 4 1 Efficiency Efficiency is the ratio of total output power to the input power It is typically measured at full load and nominal input voltage Test 1 Turn on the fan 2 Se...

Страница 19: ...Appendix A Evaluation Board Schematic 19...

Страница 20: ...x 886 3 4513485 Email DCDC delta com tw Warranty Delta offers a two 2 year limited warranty Complete warranty information is listed on our web site or is available upon request from Delta Information...

Отзывы: