The output voltage tracking feature (Figure 40 to Figure 
42) is achieved according to the different external 
connections. If the tracking feature is not used, the 
TRACK pin of the module can be left unconnected or 
tied to Vin. 

 

For proper voltage tracking, input voltage of the tracking 
power module must be applied in advance, and the 
remote on/off pin has to be in turn-on status. (Negative 
logic: Tied to GND or unconnected. Positive logic: Tied 
to Vin or unconnected) 
 

 

 

Figure 40: 

Sequential Start-up

 

 

 

Figure 41: 

Simultaneous

 

 

 

Figure 42: 

Ratio-metric

 

   

 

 
                                                                                         
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

FEATURE DESCRIPTIONS (CON.) 

 
The amount of power delivered by the module is the 
voltage at the output terminals multiplied by the output 
current. When using the trim feature, the output voltage 
of the module can be increased, which at the same 
output current would increase the power output of the 
module. Care should be taken to ensure that the 
maximum output power of the module must not exceed 
the maximum rated power (

Vo.set x Io.max 

 P max)

 

Voltage Margining 
 

Output voltage margining can be implemented in the 
DNS modules by connecting a resistor, R 

margin-up

, from the 

Trim pin to the ground pin for margining-up the output 
voltage and by connecting a resistor, R

margin-down

, from the 

Trim pin to the output pin for margining-down. Figure 39 
shows the circuit configuration for output voltage 
margining.

 

If unused, leave the trim pin unconnected.

 

calculation tool is available from the evaluation 
procedure which computes the values of R 

margin-up

and  

R

margin-down

 for a specific output voltage and margin 

percentage.  

Vo

On/Off

Vin

GND

Trim

Q2

Q1

Rmargin-up

Rmargin-down

Rtrim

Figure 39: 

Circuit configuration for output voltage margining 

 

Voltage Tracking   
 

The DNS family was designed for applications that have 
output voltage tracking requirements during power-up 
and power-down. The devices have a TRACK pin to 
implement three types of tracking method: sequential 
start-up, simultaneous and ratio-metric. TRACK 
simplifies the task of supply voltage tracking in a power 
system by enabling modules to track each other, or any 
external voltage, during power-up and power-down.   

           

 

By connecting multiple modules together, customers can 
get multiple modules to track their output voltages to the 
voltage applied on the TRACK pin.

 

PS1 

PS1 

PS2 

PS2 

PS1 

PS1 

PS2 

PS2 

PS1 

PS1 

PS2 

PS2 

-

Δ

Содержание Delphi Series DNS

Страница 1: ...ons OPTIONS Negative on off logic Tracking feature SIP package Delphi DNS Non Isolated Point of Load DC DC Power Modules 2 8 5 5Vin 0 75 3 3V 6Aout The Delphi Series DNS 2 8 5 5V input single output n...

Страница 2: ...it Current Hiccup Mode Io s c 3 5 Adc DYNAMIC CHARACTERISTICS Dynamic Load Response 10 F Tan 1 F Ceramic load cap 2 5A s Vin 5V Positive Step Change in Output Current 50 Io max to 100 Io max 160 mV Ne...

Страница 3: ...efficiency vs output current 1 2V out Figure 6 Converter efficiency vs output current 0 75V out 90 91 92 93 94 95 96 97 98 1 2 3 4 5 6 LOAD A EFFICIENCY 4 5V 5V 5 5V 84 86 88 90 92 94 96 98 1 2 3 4 5...

Страница 4: ...ple noise at 3 3Vin 2 5V 6A out Figure 8 Output ripple noise at 3 3Vin 1 8V 6A out Figure 9 Output ripple noise at 5Vin 3 3V 6A out Figure 10 Output ripple noise at 5Vin 1 8V 6A out Figure 11 Turn on...

Страница 5: ...n 1 8V 6A out Figure 15 Turn on delay time at remote turn on 5Vin 3 3V 16A out Figure 16 Turn on delay time at remote turn on 3 3Vin 2 5V 16A out Figure 17 Turn on delay time at remote turn on with ex...

Страница 6: ...Typical transient response to step load change at 2 5A S from 50 to 100 of Io max at 5Vin 3 3Vout Cout 1uF ceramic 10 F tantalum Figure 21 Typical transient response to step load change at 2 5A S fro...

Страница 7: ...from 50 to 100 of Io max at 3 3Vin 2 5Vout Cout 1uF ceramic 10 F tantalum Figure 25 Typical transient response to step load change at 2 5A S from 100 to 50 of Io max at 3 3Vin 1 8Vout Cout 1uF cerami...

Страница 8: ...SIGN CONSIDERATIONS Input Source Impedance To maintain low noise and ripple at the input voltage it is critical to use low ESR capacitors at the input to the module Figure 32 shows the input ripple vo...

Страница 9: ...ve and negative On Off logic options are available in the DNS series power modules For positive logic module connect an open collector NPN transistor or open drain N channel MOSFET between the On Off...

Страница 10: ...of the module Without this external resistor the output voltage of the module is 0 7525 Vdc To calculate the value of the resistor Rtrim for a particular output voltage Vo please use the following equ...

Страница 11: ...d in the DNS modules by connecting a resistor R margin up from the Trim pin to the ground pin for margining up the output voltage and by connecting a resistor Rmargin down from the Trim pin to the out...

Страница 12: ...e TRACK pin of PS2 Please note the voltage apply to TRACK pin needs to always higher than the VoPS2 set point voltage TRACK VoPS1 PS2 VoPS2 PS1 Vin Vin On Off On Off Ratio Metric Ratio metric Figure 4...

Страница 13: ...le To enhance system reliability the power module should always be operated below the maximum operating temperature If the temperature exceeds the maximum module temperature reliability of the unit ma...

Страница 14: ...NS04S0A0R06 Standard Output current vs ambient temperature and air velocity Vin 3 3V Vo 2 5V Either Orientation DNS04S0A0R06 Standard Output Current vs Ambient Temperature and Air Velocity Vin 3 3V Vo...

Страница 15: ...DS_DNS04SIP06A_07172008 15 MECHANICAL DRAWING SMD PACKAGE OPTIONAL SIP PACKAGE...

Страница 16: ...A 94 0 CONTACT www delta com tw dcdc USA Telephone East Coast 888 335 8201 West Coast 888 335 8208 Fax 978 656 3964 Email DCDC delta corp com Europe Telephone 41 31 998 53 11 Fax 41 31 998 53 53 Email...

Отзывы: