Delta Electronics 10GBASE-LRM SFP+ Optical Transceiver LCP-10G3B4EDR Скачать руководство пользователя страница 10

 

 

LCP-10G3B4EDR

 

DELTA ELECTRONICS, INC.

 

10 Revision: 

0B

2008/9/5

www.deltaww.com

 

  Timing parameters for SFP+ management 

Parameter 

Symbol 

Min. 

Max. 

Unit 

Note 

TX_DISABLE Assert time 

t_off 

 

10 

µ

sec 1 

TX_DISABLE Negate time 

t_on 

 

msec 

Time to initialize 2-wire 
interfase 

t_2w_start_up  

300  msec  3 

Time to initialize 

t_start_up 

 

300 

msec 

Time to initialize cooled 
module 

t_start_up_cooled

 90 

sec 

Time to Power Up to Level 2 

t_power_level2

 

300 

msec 

Time to Power Down from 
Level 2 

T_power_down

 300 

msec 

TX_Fault assert 

TX_Fault_on 

 

msec 

TX_Fault assert for cooled 
module 

TX_Fault_on  

50  msec  7 

TX_Fault Reset 

t_reset 

10 

 

µ

sec 

Module Reset 

t_module_reset

 

TBD 

msec 

TBD 

RS0, RS1 rate select timing 
for FC 

t_RS0_FC, 

RS1_FC 

 

500 

µ

sec 

RS0, RS1 rate select timing 
non FC 

t_RS0, t_RS1 

 

10 

msec 

RX_LOS assert delay   

t_los_on 

 

100 

µ

sec 

10 

RX_LOS negate delay 

t_los_off 

 

100 

µ

sec 11 

Notes: 

1) 

Rising edge of TX_Disable to fall of output signal below 10% of nominal.

 

2) 

Falling edge of TX_Disable to rise of output signal above 90% of nominal. This only applies in normal 
operation, not during start up or fault recovery.

 

3) 

From power on or negation of TX_Disable.

 

4) 

From power on or TX_Disable negated during power up, or TX_Fault recovery, until non-cooled power 
level 1 part (or non-cooled power level 2 part already enabled at power level 2 for TX_Fault recovery) 
is fully operational. 

 

5)  From falling edge of stop bit enabling power level 2 until non-cooled module is fully operational. 
6)  From falling edge of stop bit disabling power level 2 until module is within power level 1 requirements. 
7)  From Occurrence of fault to assertion of TX_Fault. 
8)  Time TX_Disable must be held High to reset TX_Fault. 
9) From 

assertion 

till stable output. 

10) From Occurrence of loss of signal to assertion of LOS 
11) From Occurrence of presence of signal to negation of RX_LOS. 
 
 
 
 
 
 
 

Содержание 10GBASE-LRM SFP+ Optical Transceiver LCP-10G3B4EDR

Страница 1: ...1W Description The LCP 10G3B4EDR is a hot pluggable 10Gbps small form factor plus transceiver module integrated with the high performance 1310nm FP Laser transmitter high sensitivity linear PD TIA re...

Страница 2: ...3 135 3 30 3 465 V Relative Humidity non condensation 5 85 DC Common Mode Voltage VCM 0 3 6 V Low Speed Electrical Characteristics VCC 3 135V to 3 465V Parameter Symbol Min Typ Max Unit Note Total Sup...

Страница 3: ...er Symbol Min Typ Max Unit Note Data Rate R 10 3125 Gb s Signaling speed variation from nominal 100 ppm Average Output Power Pavg 6 5 0 5 dBm Wavelength 1260 1355 nm RMS Spectral Width at 1260nm RMS S...

Страница 4: ...naling speed nominal TS 10 3125 Gb s Signaling speed variation from nominal 100 ppm Center Wavelength 1260 1355 nm Overload in OMA PO 1 5 dBm Stressed sensitivity in OMA RSO 6 5 dBm 1 Stressed sensiti...

Страница 5: ...ial Interface Clock 6 MOD_ABS Module Absent connected to VeeT or VeeR in the module 4 7 LVTTL I RS0 Not Implement 8 LVTTL O RX_LOS Receiver Loss of Signal Indication 2 9 LVTTL I RS1 Not Implement 10 V...

Страница 6: ...D_ABS RX_LOS 1 TX_Fault TX_Fault is a module output pin that when High indicates that the module transmitter has detected a fault condition related to laser operation or safety The TX_Fault output pin...

Страница 7: ...OD_DEF0 5 SCL SDA SCL is the 2 wire interface clock and SDA is the 2 wire interface data line SCL and SDA are pulled up to a voltage in the range of 3 14V to 3 46V on the host 6 RX_LOS RX_LOS when Hig...

Страница 8: ...LCP 10G3B4EDR DELTA ELECTRONICS INC 8 Revision 0B 2008 9 5 www deltaww com Recommend Circuit Schematic...

Страница 9: ...EDR DELTA ELECTRONICS INC 9 Revision 0B 2008 9 5 www deltaww com Package Outline Drawing for Metal Housing with Bail de latch Latch Color Identifier Blue Complies with 21 CFR 1040 10 and 1040 11 Made...

Страница 10: ...0 sec 10 RX_LOS negate delay t_los_off 100 sec 11 Notes 1 Rising edge of TX_Disable to fall of output signal below 10 of nominal 2 Falling edge of TX_Disable to rise of output signal above 90 of nomin...

Страница 11: ...ormation about the module s present operating conditions 2 wire address 1010000 X A0h 2 wire address 1010001 X A2h 0 0 55 Alarm and Warning Thresholds 56 bytes 95 Serial ID Defined by SFP MSA 96 bytes...

Страница 12: ...102 00 17 16 60 05 103 00 18 00 61 1E 104 00 19 16 62 00 105 00 20 44 D 63 CS1 Note 1 106 00 21 45 E 64 01 107 00 22 4C L 65 1A 108 00 23 54 T 66 00 109 00 24 41 A 67 00 110 00 25 20 68 SN Note 2 111...

Страница 13: ...P 3dB 28 29 2 TX Power High Warning P 2dB 30 31 2 TX Power Low Warning P 2dB dBm 3 32 33 2 RX Power High Alarm P0 2 34 35 2 RX Power Low Alarm PS 2 36 37 2 RX Power High Warning P0 38 39 2 RX Power L...

Страница 14: ...when Tx output power is below low alarm level 113 7 Rx Power High Alarm Set when received power exceeds high alarm level 113 6 Rx Power Low Alarm Set when received power is below low alarm level 113 5...

Страница 15: ...act Discharge IEC EN 61000 4 2 Electrostatic Discharge ESD to the Duplex LC Receptacle Air Discharge IEC EN 61000 4 2 Human Body Model HBM MIL STD 883E Method 3015 7 EIA JESD22 A114 Electrostatic Disc...