background image

EN

20

21

11/  Favourite positions

You can save up to 2 favourite positions: 

 and 

.

 

❷ 

Set the shutter to the required position. 

 Press 

 and 

 

for 3 seconds to save the position. 

The shutter will be activated briefly to confirm the association. 

 

Release.

Repeat the operations for the 2nd favourite position.

> 3s

12/  Association with an alarm control unit

Association of the motor with an alarm control unit enables:
- the anti-intruder function (attempt to lift up the shutter), which is only possible 
with the Radio Performance DxRP2 and xRP2 motors, non-compatible with the 

Efficacité RE2 radio motors.

- the surveillance stop/start report, compatible with all motors.

12.1  Associating Performance DxRP2 or xRP2 radio motor

>5s

Bip

ON OFF

>5s

Bip

ON

Bip

> 3s

x 2

Set the alarm control unit to Maintenance mode, then to “Add product” mode.

 Set the alarm control unit to “Add product” mode.

 Associate the intruder mode with the alarm control unit

Press  button B on the front 
panel of the remote control 
twice

, until the LED flashes 

orange.

Then, press and hold the 

 

button for ~3 seconds until  the 

motor is activated briefly.

The alarm control unit will beep.

The alarm control unit will beep. 

The roller shutter will be briefly 

activated twice.

For intruder detection to work, the lower stop must be recorded 
automatically with locks.

Intruder surveillance is only active if the alarm is activated and the shutter 
closed.

 Exit Add product mode and Maintenance mode

Briefly press the OFF button. 

The LED changes from red to green to confirm the action.
The alarm control unit’s led flashes a beep.

Press the OFF button once again.

The LED changes from red to green to confirm the action.

The alarm control unit beeps twice and its LED switches off. 

OFF

OFF

Bip...Bip

Содержание TYMOOV 10RE2

Страница 1: ...EN Wireless Tubular Motor range TYMOOV radio xRP2 DxRP2 xRE2 ...

Страница 2: ...nd that the risks involved have been understood Children must not play with the device Cleaning and maintenance by the user must not be carried out by unsupervised children The operating device of an unlockable switch must be in direct view of the driven part but kept away from the moving parts It must be installed at a height of at least 1 5 m The fixed control devices must be installed in a visi...

Страница 3: ...type A plate on the motor indicates the nominal torque and operating time TYMOOV xRP2 DxRP2 or xRE2 tubular motors are designed to operate intermittently 4 minutes of continuous operation They are electronically protected to prevent overheating If there is a thermal shutdown the motor will operate again after a time period of approximately 30 seconds To operate again for 4 minutes the motor must h...

Страница 4: ...g the first remote control to a motor 11 4 2 Setting stops 12 5 Modifying stops 16 6 Associating another transmitter 16 7 Linking a smoke detector directly to the motor 17 8 Grouped command 17 9 Obstacle detection 18 9 1 Setting of the obstacle detection type 18 9 2 Adjustment of the sensitivity of obstacle detection for Basic detection only 19 10 Remove one or several associations 19 10 1 Remove ...

Страница 5: ...ling L Total length TYMOOV 6 10 and 20 Nm 395 mm 424 mm Tube L length for drilling wheel attachment by screws or rivet 2 3 Motor head position The motor head must be positioned on the mount such that the cable outlet is in the lower part when seen horizontally 2 4 Attaching the motor to the mount Push the tube motor A onto the mount B until it locks into place click 8 NO 8 NO 8 NO 4 OK 4 OK 4 OK C...

Страница 6: ...associate The corresponding shutter will be activated briefly once Once the motor has been found press briefly After a few seconds the shutter will be activated briefly twice to confirm the association To exit association mode hold for 3 seconds You will then be able to pass to Set stops mode 3s The electrical wiring must comply with EN IEC and national institute standards for installation e g NF ...

Страница 7: ...n slightly so that there is no force on the shutter x 1 Upper physical stop Lower physical stop Stop on shutter blade Press the button briefly until the shutter reaches the upper stop The stop position will now be automatically set The motor will be activated briefly The stop position will now be automatically set The motor will be activated twice Automatic upper stop Automatic lower stop The stop...

Страница 8: ...lease the and buttons at the same time To scroll step by step briefly press then release the and buttons at the same time Press button B on the front panel of the remote control until the LED flashes green Then press and hold the button for 3 seconds until the motor is activated briefly The upper manual stop will now be set The motor will be activated briefly Press the button to move the shutter t...

Страница 9: ...he opening of roller shutters in the event that smoke is detected Motor type Linking to a wireless smoke detector TYMOOV xRP2 and DxRP2 Wireless smoke detector directly linked to the motor TYMOOV xRE2 Version S02 04 00 Wireless smoke detector directly linked to the motor TYMOOV xRE2 Version S02 04 00 Only by linking your motor and the wireless smoke detector to a TYXAL alarm system To find out the...

Страница 10: ... DxRP2 motors you have a choice between two detection modes Protect Detection default mode more efficient obstacle detection preventing the apron from unwinding in the casing Basic Detection detection of obstacles with unwinding of the apron in the casing Repeat the operations above to switch between modes The Radio Efficacité xRE2 motor only has Basic obstacle detection 3s x 2 Press button B on t...

Страница 11: ...unit to Maintenance mode then to Add product mode Set the alarm control unit to Add product mode Associate the intruder mode with the alarm control unit Press button B on the front panel of the remote control twice until the LED flashes orange Then press and hold the button for 3 seconds until the motor is activated briefly The alarm control unit will beep The alarm control unit will beep The roll...

Страница 12: ...t the motor is in association wait mode it only remains in association mode for 2 minutes 12 2 Associating an Efficacité RE2 radio motor 12 3 Defining the motor s operating mode 5s Bip ON OFF 3s x 1 x 2 On the motor remote control press the button for more than 3 seconds until the motor operates briefly Set the alarm control unit to Maintenance mode open it and then briefly press button 2 of the c...

Страница 13: ... stop then a manual stop Press the push button 2 seconds so that the motor operates in the up or down direction When the motor detects the 1st stop upper or lower then the motor operates once 2s x 1 OR x 3 2s 2s x 2 2s x 2 STOP OR Press the push button 2 seconds so that the motor operates in the opposite direction Briefly press the push button to stop the motor at the position corresponding to the...

Страница 14: ...2 manual stops x 3 2s 2s x 2 2s x 2 STOP OR Press the push button 2 seconds so that the motor operates in the up or down direction Briefly press the push button to stop the motor at the position corresponding to the manual stop Then if the shutter is down briefly press the push button 3 times then press and hold the push button 2 seconds if the shutter is up briefly press the push button 2 times t...

Страница 15: ...n on the remote control 3 times The motor operates twice x 2 x 1 TYMOOV xRP2 and DxRP2 software version S02 04 00 and higher The motor operates once x 2 x 1 TYMOOV xRE2 software version S02 04 00 and higher The motor does not respond TYMOOV xRE2 or xRP2 or DxRP2 software version S02 04 00 See label on the motor 17 Troubleshooting Press the push button once to move the shutter down or up Switch off...

Страница 16: ...www deltadore com 05 21 ...

Отзывы: