4- Date and time settings

3- Home automation functions

JJ/MM/AA

HH/MM

1

2

4

5

3

EXIT

Enter the date, then the time.  
Confirm with OK.

These settings are only available if the control output is used and declared 
(configuration menu 2-08 > 0, installation instructions).
The Heat/Cool option will only be available if the presence of a cooling 
system has been declared (installer menu, 0-06).
Press '+' or '-'. Confirm with OK.

Turn the 
selector 
knob to exit 
the mode

Turn the selector 
knob  
to exit the mode

5- Setting the temperature settings

Return to   
the previous                                                                                                                                          
setting

5      30°C

1

2

4

3

5

EXIT

5      30°C

6

7

5      16°C

The home automation functions control the following functions either locally 
or remotely via a tablet or a smartphone:
- heating control (heat/cool mode, Auto/Off/Absence/override mode),
- display of the consumption data over the current month and the history of 
previous months (electricity, gas, etc.).
To get this service, you have to associate the room unit with the TYDOM 
home automation gateway.

ADSL BOX

Wifi (local)

or

Internet (remote)

Smartphone

Tablet

OR

TYDOM 2000

Wireless

Ethernet cable

TYDOM 1000

1

Volets

Alarme

Autres

Eclairages

Garage

Scénarios

Chauffage

Portail

Pièces

TYDOM 2000

1

Volets

Alarme

Autres

Eclairages

Garage

Scénarios

Chauffage

Portail

Pièces

Example with the TYDOM 2000 home automation gateway

Содержание TYBOX 1010 WT

Страница 1: ...TYBOX 1010 WT www deltadore com User guide ...

Страница 2: ...ture settings Heating and DHW Domestic Hot Water overrides possible Access to consumption data Access to the system status i button and to any faults Changeover to standby after a 30 seconds time out period 2 Technical unit indicator lights Bus indicator light Blinks in sync with the data Steady blinking Bus fault Off Power supply failure Electronic meter indicator light On Normal operation Blinki...

Страница 3: ...g 5 30 C 1 2 4 3 5 EXIT 5 30 C 6 7 5 16 C The home automation functions control the following functions either locally or remotely via a tablet or a smartphone heating control heat cool mode Auto Off Absence override mode display of the consumption data over the current month and the history of previous months electricity gas etc To get this service you have to associate the room unit with the TYD...

Страница 4: ...tric consumption of your system turn the selector knob to select the symbol Displays the con sumption for the current month History Press to display the overall consump tion history from the beginning of the current year then for the previous year History Press to display the consumption history for the12 previous months Press If you own a hybrid boiler the heating and DHW consumption data will be...

Страница 5: ... Repeat the procedure for the other zone where necessary Programme P6 can be viewed Press to scroll the programme steps Modifications to programme P6 are applied to all the days when the programme is assigned This menu enables the following functions assigning a daily programme P1 to P6 for each day of the week and appli cable in AUTO mode modifications to programme P6 P1 to P5 are not editable modi...

Страница 6: ...ter each mainte nance operation menu 2 20 JJ MM AA 18 02 00 00 Example You are away from Friday 10 02 to Saturday 18 02 The heating is on Frost Protection mode over this period The DHW system is off modifiable installer menu 1 05 Automatic return to AUTO mode on Saturday 18 02 at 00 00h Set the Frost Protection temperature except for Cool mode 9 Days home 6h 24h 0h 21h This menu monitors programme ...

Страница 7: ...11 Heating override 12 DHW override 6h 8h 0h 0h 17h 15h30 23h Press the i button several times to view the system s status In this mode the heating is off the DHW override is possible the consumption data is displayed button the system status i button and any faults refer to the Help section are displayed Number of days to maintenance Boiler operating hours meter 13 Stop mode h ON 0 2 3 4 5 When y...

Страница 8: ...bol does not appear The DHW is not managed by the device Refer to menu 1 04 installation instructions The symbol blinks Boiler maintenance is due in less than 30 days OR A system fault has been identified From the AUTO or modes press the i button to display the type of Fault dEF 6 There is a communication fault between TYBOX and the technical unit Bus A Check the system dEF 7 There is a communicati...

Страница 9: ...2004 108 EC 2006 95 EC EN ...