Delta Controls ASM-24 Скачать руководство пользователя страница 18

Access System Manager ASM-24 (Rev 1.2) Installation & Application Guide

Page 18 of 18

Access System Manager

CE - DECLARATION OF CONFORMITY

according to ISO/IEC Guide 22 and EN 45014

Manufacturer's Name:

Delta Controls

Manufacturer's Address:

17850 56

th

 Avenue

Surrey, British Columbia
Canada
V3S 1C7

declares that the product (s):

Product Name:

Access System Manager

Model Numbers:

ASM-24x

Product Options:

All

conforms to the following Product Specifications:

EMC:

EN 55022:1994

Radiated and Conducted Emissions

Class A

EN 50082-1:1997

Generic Immunity Standard: Part 1. Residential

EN 61000-4-2:1995

ESD Immunity

Level B

EN 61000-4-3:1996

RF Electromagnetic Field Immunity

Level A

ENV 50204:1995

RF Electromagnetic Field Immunity (Keyed Carrier)

Level A

EN 61000-4-4:1995

EFT/Burst Immunity

Level B

EN 61000-4-5:1995

Surge Immunity

Level B

EN 61000-4-6:1996

Conducted Immunity

Level A

EN 61000-4-11

Voltage Dips / Interruptions

Level B/C

Supplementary Information:

The product(s) herewith comply with the requirements of the EMC Directive
89/336/EEC.  The product(s) were tested in a typical configuration.

Lee Dickson
Quality Assurance Manager

    

Содержание ASM-24

Страница 1: ...through a network of Door Modules which act as extended I O to the Access System Manager TABLE OF CONTENTS PRODUCT DESCRIPTION 1 MODEL NUMBERS 2 ACCESSORIES 2 PACKAGE CONTENTS 2 REQUIRED TOOLS 2 OTHER...

Страница 2: ...24 Rev 1 2 Stylized Enclosure for quick mounting Access System Manager ASM 24 Rev 1 2 Installation Application Guide REQUIRED TOOLS Terminal flat head screwdriver Wire cutters and strippers Screws and...

Страница 3: ...ss Door Modules per Access System Manager ASM 24 For MS TP Maximum of 99 nodes per MS TP segment Visual LED status of network activity Ethernet ASM 24E only 10 Base T Visual LED Status of network acti...

Страница 4: ...Manager ASM 24 Rev 1 2 Installation Application Guide Page 4 of 18 Access System Manager Size Controller Enclosure 5 75 x 8 25 x 2 25 14 6 cm x 21 cm x 5 6 cm Weight c w Enclosure Controller Enclosure...

Страница 5: ...T DNA RUN CLEAR Run clear jumper 5 4 RS232 RS232 1 2 3 TX GND RX DCD DTR RX TX 2 1 RS485 NET2 ACT Link POWER SCAN 2 1 RS 485 TX NET1 RX POWER 24 GND 2 1 AC PWR IN DNA jumper Area System Subnet jumper...

Страница 6: ...e when the device is transmitting data through the associated port and the red LED will flash to indicate when the device is receiving data through the port Network NET2 RS 485 Communication Status In...

Страница 7: ...dressing DNA which is dependent on the Device Type setting and refers to the ability of inheriting portions of its address from higher up device s is enabled when the jumper is in place across the jum...

Страница 8: ...ividual DIP switch represents a pre defined value as printed on PCB beside the address block which added together forms the device address MOUNTING The Access Control Manager is designed for quick and...

Страница 9: ...Delta Controls Access System Manager Page 9 of 18 24 VAC Access System Manager Power Connection wiring detail Door Module Power Out used power and battery backup Access System Manager...

Страница 10: ...INKnet terminator boards when you have more than 1 or 2 devices 4 There are a maximum of 12 Access Door Modules on LINKnet ASM Access System Manager ADM Access Door Module TRM ADM Access Door Module T...

Страница 11: ...0 2 FEMALE DB9 connector Wieland connector 10 ft 3 m The cable end with the DB25 or DB9 connector connects to a COM port on your PC The other end connects to the COM 1 port on the ASM as shown in the...

Страница 12: ...ion CBL931 1 MALE DB25 connector Wieland connector 10 ft 3 m Modem Cable With DB25 The cable end with the DB25 connector connects to the modem The other end connects to the COM 1 port on the ASM as sh...

Страница 13: ...BL937 Ethernet Crossover Cable RJ 45 Connectors 10 ft 3 m Direct Ethernet Connection to a ASM using Direct Connect cross patch Cable PC F1 2 AMP SLO BLO Off On 1 2 4 8 16 32 64 128 698135 Rev 1 0 Delt...

Страница 14: ...To make the Ethernet cables 1 For either type of cable sort out the pin numbers of the wires according to the sub sections Standard Patch Cable and Direct Connect Cable that follow 2 Insert the correc...

Страница 15: ...ominal velocity of propagation of 66 or higher Topology Ensure the cable is installed as a daisy chain from one device to the next Max Controllers Access Door Modules The maximum number of controllers...

Страница 16: ...the V3 22 Technical Reference Manual for further details on configuring the controllers network configuration changing baud rates etc See RS 485 Network Installation Guide DOC818 11 for details on wir...

Страница 17: ...can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a resi...

Страница 18: ...994 Radiated and Conducted Emissions Class A EN 50082 1 1997 Generic Immunity Standard Part 1 Residential EN 61000 4 2 1995 ESD Immunity Level B EN 61000 4 3 1996 RF Electromagnetic Field Immunity Lev...

Отзывы: