DELTA BREEZ SIG110 Скачать руководство пользователя страница 4

4

Model: 

SIG80 / SIG80M /SIG80D/ SIG110 / SIG110H / SIG110D

OFF

ON

L

N

POWER SWITCH

JUNCTION BOX

SWITCH BOX

WHITE

BLACK

GREEN

GRD

BLACK

ON/OFF SWITCH

(purchase separately)

SWITCH BOX

120 VAC

LINE IN

WHITE
GROUND

(bare)

POWER

SWITCH

WIRING

PLATE

Single Speed Models: SIG80, SIG110
Motion Model: SIG80M

HI

POWER SWITCH

MODE SWITCH

JUNCTION BOX

SWITCH BOX

WHITE

BLACK

OFF

ON

WHITE

BLUE

GREEN

GRD

L

N

L

N

ON/OFF SWITCH

(purchase separately)

SWITCH BOX

120 VAC

LINE IN

WIRING

PLATE

BLACK
WHITE

GROUND

(bare)

BLUE

MODE

SWITCH

POWER

SWITCH

Humidity Model: SIG110H
Dual Speed Model: SIG110D / SIG80D

 PREPARATION

Tools Required for Assembly (not included): Hammer, 

Flathead Screwdriver, Wire Nuts, Nails, Duct Tape, 

Phillips Head Screwdriver, Utility Knife
Helpful Tools (not included): Electric Drill, Drill Bits

WARNING: Turn off electricity at breaker box 

before beginning installation.

Carefully remove unit from carton.
Check area above installation location to be sure that 

wiring can run to the planned location and that duct 

work can be run. Make sure the area is sufficient for 

proper ventilation.
Inspect duct work and wiring before proceeding with 

installation.
Before installation, provide inspection and future 

maintenance access at a location that will not 

interfere with installation work.
You may need the help of a second person to install 

this fan: one person on the attic side and one on the 

room side.

Note: Installations may vary depending on how the 

previous bath fan was installed. Supplies necessary 

for the installation of your bath fan are not all included. 

However, most are available at your local home 

improvement or hardware store.

Properly insulate around the fan to minimize building 

heat loss and gain. 

Locate unit above (GFCI-protected circuit required) 

or within 5 feet of the shower head.

Locate unit away from heating or cooling sources 

which can affect humidity levels.

Do not locate near window. Unit may respond to the 

outdoor humidity level.

Unit must be installed in ceiling to properly sense 

moisture.

Locate unit only on flat ceilings up to 12 feet high for 

proper sensing.

The fan will operate most efficiently when located 

where the shortest possible duct run and minimum 

number of elbows will be needed.

Use a roof cap or wall cap that has a built-in damper 

to reduce backdrafts.

Roof cap

(with built-in

damper)

Seal gap

around 

housing

Caulk termination

to duct

Fan housing

Short piece of flexible

duct helps alignment

and absorbs

sound

or

Wall cap

(with built-in

damper)

Wall cap

(with built-in

damper)

WIRING DIAGRAM

Содержание SIG110

Страница 1: ...ckage Contents 2 General Safety Information 3 Preparation and Wiring Diagrams 4 Assembly Instructions New Construction 5 Assembly Instructions Existing Construction 6 Grille Installation 10 Operation 10 Care and Maintenance 11 Troubleshooting 12 Dimensions 13 Product Specifications 13 Warranty 14 VENTILATION FAN MODEL SIG80 SIG80M SIG80D SIG110 SIG110H SIG110D ...

Страница 2: ...NTENTS 1 2 3 4 5 PART DESCRIPTION QTY Fan Body 1 Grille 1 Suspension bracket Ⅰ 13 318 5mm 2 Suspension bracket Ⅱ 13 318 5mm 2 Duct Connector 1 A B C HARDWARE CONTENTS Images are to scale X 4 X 4 X 1 Long Wood Screw 4 x 25mm Short screw 8 32x1 4 Duct Screw M4x12mm ...

Страница 3: ...pment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and local code authorities 5 When cutting or drilling into the wall or ceiling do not damage electrical wiring and other hidden utili...

Страница 4: ...ovide inspection and future maintenance access at a location that will not interfere with installation work You may need the help of a second person to install this fan one person on the attic side and one on the room side Note Installations may vary depending on how the previous bath fan was installed Supplies necessary for the installation of your bath fan are not all included However most are a...

Страница 5: ...or joist spacing 16 in 24in insert suspension bracket I and suspension bracket II into the bracket cover on the duct connector side and the back of the fan body Install the suspension brackets to the joists with nails and secure the suspension brackets to the fan body by using the short screws provided Hardware B Short screw NEW CONSTRUCTION ATTACHING TO THE JOIST Suspension Bracket II Suspension ...

Страница 6: ... Reattach fan junction box cover c 5 Connect a 4 in circular duct a not supplied and vent to the outside Secure it with duct tape not supplied or clamp not supplied to make the connection secure and air tight 6 Punch out Mask from packaging Insert mask and finish celling Mask protects unit during construction Remove before installing Grille c b a 4 joist joist a 5 6 Turn off power source Review al...

Страница 7: ...an be sure to cut a 10 25 in x 10 25 in opening for the fan body 4 Remove fan unit by removing 3 screws 5 A piece of wood not supplied is screwed in from below through the ceiling board Suggested size is 1 in x 3 in x 14 in Position the screws far enough away from the edge of the ceiling board that it does not crumble and give way Put screws in both ends of wood beyond the 10 25 in hole Keep screw...

Страница 8: ...n page 4 Wire connections are as follows black to live switch wire white to neutral green to ground Reattach fan junction box cover c 7 Insert housing can into the ceiling cut out Secure the housing can from below by using 2 long wood screws through the flange into the wood support and 2 long wood screws through the flange into the joist Hardware A Long wood screw 8 Attach the duct connector from ...

Страница 9: ...ws provided Hardware B Short screw 2 Remove the fan junction box cover a Using wire nuts not supplied connect house wires to fan wires b as shown in the wiring diagram on page 4 Wire connections are as follows black to live switch wire white to neutral green to ground Reattach fan junction box cover c 3 Connect a 4 in circular duct a not supplied and vent to the outside Secure it with duct tape no...

Страница 10: ...ER switch on to operate at humidity control mode the LED indicator will be blue When the ambient humidity is higher than the user adjustable set point the fan will run at full speed and the LED indicator is blue When the ambient humidity is lower than the set point the fan will continue to run at the full speed until a 10 minute time delay has elapsed and then will automatically change to the user...

Страница 11: ... immerse resin parts in water over 140º Fahrenheit Turn off power source Review all safety precautions CARE AND MAINTENANCE 1 To remove grille squeeze springs and pull down 2 Wash and clean the grille in a sink and dry with a cloth 3 Remove dust and dirt from the fan body with a vacuum cleaner 4 Dampen cloth with dust detergent and wipe the fan body Then wipe dry with a clean cloth 5 Replace grill...

Страница 12: ...rating on the fan matches the size of your room 2 Check damper to ensure it is opening and closing properly If the damper has become damaged please call Customer Service 3 Be sure you do not have any sharp bends in duct closer than 18 in to the fan discharge 4 Use recommended size ducting to reduce fan noise 5 Be sure the fan is securely attached to your ceiling joists The fan is not clearing the ...

Страница 13: ... SP CFM Weight lb Max Current amps Note SIG80 120 60 8 7 80 10 0 30 Single Speed SIG80M 120 60 8 7 80 10 0 30 Motion Sensor SIG80D 120 60 8 7 80 10 0 30 Dual Speed SIG110 120 60 13 6 110 10 0 38 Single Speed SIG110H 120 60 13 6 110 10 0 38 Humidity Sensor SIG110D 120 60 13 6 110 10 0 38 Dual Speed Note Design and specifications subject to change without notice ...

Отзывы: