The fan is not turning on

1. Power off
2. Faulty switch
3. Faulty wire connection

1. Make sure power supply is on.
2. Test or replace switch.
3. Check wire in switch box.

The fan seems louder 
than it should

1. CFM 

2.   Damper not working 

properly or damaged 

3.   Bend in duct too close 

to fan discharge

4.   Fan  discharge 

reduced to fit smaller 
duct

5.   Fan body not securely 

attached

1.   Be sure the CFM rating on the fan matches the 

size of your room.

2.   Check damper to ensure it is opening and closing 

properly. If the damper has become damaged, 
please call Customer Service.

3.   Be sure you do not have any sharp bends in duct 

closer than 18 in. to the fan discharge.

4.   Use recommended size ducting to reduce fan 

noise. 

5.   Be sure the fan is securely attached to your ceiling 

joists.

The fan is not clearing 
the room

1.   Insufficient intake 

airflow within room 

2.   Insufficient CFM

1.   Be sure a door or window is slightly ajar or opened 

to allow airflow. The fan is not able to draw air out 
of the room without enough airflow to draw in from.

2.   Be sure the CFM rating on the fan matches the 

requirements for your room size.

Содержание RAD80L

Страница 1: ...ing Parkway Fremont CA 94538 US Toll Free Number 1 888 979 9889 TABLE OF CONTENTS Package Contents 2 Important Instructions 3 Preparation 4 Assembly Instructions 6 Wiring Instructions 10 Operating Instructions 10 Care and Maintenance 11 Troubleshooting 13 Dimensions 14 Product Specifications 14 Warranty 15 VENTILATION FAN WITH LIGHT AND HEATER MODEL RAD80L ...

Страница 2: ...Y Fan Body 1 Grille Assembly 1 26W max type GU24 Fluorescent Lamp 1 Light Lens 1 Suspension Bracket I 2 Suspension Bracket II 2 PACKAGE CONTENTS A B C HARDWARE CONTENTS Wood Screw 4x14 Qty 8 Short Machine Screw M4x12 Qty 4 Machine Screw M5x14 Qty 1 ...

Страница 3: ...son s in accordance with all local and safety codes including the rules for fire rated construction For use in non fire rated installations only Sufficient air supply is required for proper combustion and the exhaustion of gases through the chimney flue of fuel burning equipment to prevent back drafting See the standards of NFPA National Fire Protection Association and ASHRAE American Society for ...

Страница 4: ...sing Dimension W Housing Dimension H 14 38 in 8 25 in 5 50 in Proper insulation around the fan to minimize building heat loss and gain Locate unit above GFCI protected circuit required or within 5 feet of the shower head Locate unit away from heating or cooling sources The fan will operate most efficiently when located where the shortest possible duct run and minimum number of elbows will be neede...

Страница 5: ...accessible area attic or crawl space above the planned installation location and existing duct and wiring CAUTION Check area above installation location to ensure that Duct work can be run and the area is sufficient for proper ventilation Wiring can be run to the planned location No wiring or other obstructions can interfere with installation WARING To reduce the risk of fire do not store or use g...

Страница 6: ...he fan body is level and perpendicular with the joist and flush with ceiling surface c Allow for thickness of the ceiling board used in your application Fan body should be flush with ceiling board d Secure the suspension brackets to joists with the wood screws C e Secure the suspension brackets to fan body with the short machine screws A f Remove tap before connecting the duct as shown in Figure 1...

Страница 7: ...nd air tight b Do not install the unit where ducts are configured as shown in Figure 2 2 Install the duct with a gradient of 1 2 to the outside 3 Remove the fan junction box cover a Using wire nuts not supplied connect house wires to fan wires b as shown in the wiring diagram on page 10 Reattach fan junction box cover c Turning angle too large Duct shrink Too many elbows Elbow near the body Minimu...

Страница 8: ...eck the plug from the heating unit into the receptacle marked Heat b Plug the Light Connector into the receptacle marked Light c Install the Grille Assembly into the Fan Body using the Machine Screw B CAUTION Do not use Wood Screw C in place of Machine Screw B Vent Light Heat 2 B C Wood screw 4x14 B Machine screw M5x14 4 1 4 2 4 3 ...

Страница 9: ...9 Model RAD80L ASSEMBLY INSTRUCTIONS d Install a 26W max type GU 24 fluorescent lamp into Grille Assembly e Install the Light Lens into Grille Assembly 2 3 2 4 4 4 4 5 ...

Страница 10: ...ed for branch circuit wiring Each power wire light fan heater must have its own switch to operate independently 5 For supply connections use wire rated for at least 90ºC See wiring diagram for wire size CAUTION Failure to secure the reflector screws may result in a rattling or humming noise WARNING This unit must be properly installed before it is used Follow instructions for cleaning user mainten...

Страница 11: ... Screw B Hardware B Machine Screw M5x12 Qty 1 Routine maintenance must be done every year CAUTION Make sure power is switched off at service panel before servicing the unit To replace lamp Use type GU24 fluorescent lamp rated to 26Watts only Allow lamp to cool before replacing To clean fan disassemble using the following steps 1 2 3 ...

Страница 12: ...e Fan Body with a vacuum cleaner Do not use abrasive cloths steel wool pads or scouring powders Never use solvents thinner or harsh chemicals when cleaning the fan 6 Replace Grille Assembly back onto Fan Body Please refer to Completing the Installation Follow the steps on pages 8 9 to assemble fan back together 4 5 6 ...

Страница 13: ...es the size of your room 2 Check damper to ensure it is opening and closing properly If the damper has become damaged please call Customer Service 3 Be sure you do not have any sharp bends in duct closer than 18 in to the fan discharge 4 Use recommended size ducting to reduce fan noise 5 Be sure the fan is securely attached to your ceiling joists The fan is not clearing the room 1 Insufficient int...

Страница 14: ... CFM Noise 1 3 Sones Voltage 120V Hertz 60Hz Power Consumption 1340W Duct Diameter 4 in Weight 12 1 lbs TYPE IC INHERENTLY PROTECTED THERMALLY PROTECTED L Dimension Ceiling opening length 14 62 in Ceiling opening width 8 50 in Ceiling opening height 5 50 in Housing dimension length 14 38 in Housing dimension width 8 25 in Housing dimension height 5 50 in ...

Отзывы: