GENERAL SAFETY INFORMATION

READ AND SAVE THESE INSTRUCTIONS 

GENERAL SAFETY INFORMATION

1.  Make sure that the electric service supply voltage is AC 

120V, 60Hz.

2.  Follow all local electrical and safety codes, as well as 

the National Electrical Code (NEC) and the Occupational 
Safety and Health Act (OSH Act).

3.  Always disconnect the power source before working on 

or near the ventilating fan, motor or junction box.

4.  Protect the power cord from sharp edges, oil, grease, 

hot surfaces, chemicals or other objects.

5.  Do not kink the power cord.
6.  Do not install the unit where ducts are confugured as 

shown in Fig.A.

7.  Provide suction parts with proper ventilation.
8.  This unit is UL Listed for use over a bathtub or shower 

when installed in a GFCI protected branch circuit.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC 
SHOCK, OR INJURY TO PERSONS, OBSERVE THE 
FOLLOWING:

1.  Use this unit only in the manner intended by the 

manufacturer. If you have questions, contact the 
manufacturer.

2. 

Before servicing or cleaning the unit, switch the power off 

at the service panel and lock the service disconnecting 
means to prevent the power from being switched on 
accidentally. When the service disconnecting means 
cannot be locked, securely fasten a prominent warning 
device, such as a tag, to the service panel.

3.  Installation work and electrical wiring must be done by 

a qualified person(s) in accordance with all applicable 
codes and standards, including fire-rated construction.

4. 

Sufficient air is needed for proper combustion and 
exhausting of gases through the flue (chimney) of fuel 

burning equipment to prevent backdrafting. Follow the 
heating equipment manufacturer’s guideline and safety 
standards such as those published by the National 
Fire Protection Association (NFPA), and the American 
Society for Heating Refrigeration and Air Conditioning 
Engineers (ASHRAE) and local code authorities.

5.  When cutting or drilling into the ceiling, do not damage 

electrical wiring and other hidden utilities.

6.  Ducted ventilating fans must always be vented to the 

outdoors.

7.  If this unit is to be installed over a tub or shower, it 

must be marked as appropriate for the application 
and be connected to a GFCI (Ground Fault Circuit 
lnterrupter) – protected branch circuit.

8.  Do not use this unit with any other solid-state control 

device. Solid-state controls may cause harmonic 
distortion, which can cause a motor humming noise.

9.  NEVER place a switch where it can be reached from a 

tub or shower.

10.  Not to be installed in a ceiling thermally insulated to a 

value greater than R40. (This is required for installation 
in Canada only).

 

Turning angle too large

Too many elbows

Fig. A

Duct shrink

Elbow near the body

.

Body

Minimum 18 in.

CAUTION

1.  For general ventilating use only. Do not use to exhaust 

hazardous or explosive materials and vapors.

2.  Not for use in cooking areas. (Fig.B)
3.  This product must properly connect to the grounding 

conductor of the supply circuit.

4.  To reduce the risk of injury to persons, install the fan at 

least 8.2 feet (2.5m) above the floor.

Cooking area

Do not install above or

inside this area

Cooking

Equipment

Fig. B

floor

45

°

45

°

Содержание 80RLED-ADJ

Страница 1: ...n Assembly Instructions Existing Construction Grille Installation Care and Maintenance Troubleshooting Dimensions Product Specifications Warranty 2 3 4 5 6 8 9 10 11 11 12 READ AND SAVE THESE INSTRUCTIONS Address 46101 Fremont Boulevard Fremont CA 94538 US Toll Free Number 1 888 979 9889 Technical Support 1 877 685 4384 Customer Sales Support www deltabreez com MFG Model VFB080B4RLED1 ...

Страница 2: ...2 PACKAGE CONTENTS 1 3 2 PART DESCRIPTION QTY 1 Fan Body 1 2 Grille 1 3 Duct Connector 1 ...

Страница 3: ...Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and local code au...

Страница 4: ...ircular duct is recommended for installation The ducting from this fan to the outside of building has a strong effect on air flow noise and energy use of the fan Use the shortest straightest duct routing possible for best performance and avoid installing the fan with smaller ducts than recommended Insulation around the ducts can reduce energy loss and inhibit mold growth Fans installed with existi...

Страница 5: ...tor 3 to the Fan Body 1 2 Remove the wiring box cover from the Fan Body 1 Remove the wiring knockout from the wiring box cover with a flathead screwdriver not included 3 Place the Fan Body 1 next to a ceiling joist or wall stud The Fan Body 1 should be level and perpendicular to the joust or stud 4 Mount the Fan Body to the joist or stud using 2 nails not included were indicated 1 2 3 4 ...

Страница 6: ...and secure it with duct tape or clamps neither included Finish ceiling work The ceiling hole should be aligned with the edge of the fan housing EXISTING CONSTRUCTION BEFORE INSTALLATION Turn off power source Review all safety precautions 1 Remove existing fan 2 Measure the opening to ensure it is large enough to accommodate the new Fan Body 7 1 2in x 7 1 4in Note 7 1 4 inch side of opening should ...

Страница 7: ...n connector 5 Remove the fan junction box cover Using wire nut not supplied connect house wires to fan wires as shown in the wiring diagram on page 4 14AWG is the smallest conductor that shall be used for branch circuit wiring Reattach fan junction box cover Reattach fan junction box cover 6 Install a circular 4 in duct not included and secure it with duct tape or clamps neither included Mount the...

Страница 8: ...le 2 and insert them into the narrow rectangular slots inside the fan Push the Grille 2 up toward the ceiling Using the switch on the back of grille choose the color temperature you want for your LED You can choose from 2700K warm white 4000K cool white and 5000K daylight white Turn on electricity at the breaker box after finishing installation CCT Switch 2 ...

Страница 9: ...º Fahrenheit Turn off power source Review all safety precautions 1 To remove grille 2 squeeze springs and pull down 2 Clean the grille 2 with a dry cloth 3 Remove dust and dirt from the fan body 1 with a vacuum cleaner 4 Dampen cloth with dust detergent and wipe the fan body 1 Then wipe dry with a clean cloth 5 Replace grille 2 back onto fan body 1 refer to page 8 Grille Installation 6 Turn on pow...

Страница 10: ...per has become damaged please call Customer Service 3 Be sure you do not have any sharp bends in duct closer than 18 in to the fan discharge 4 Use recommended size ducting to reduce fan noise 5 Be sure the fan is securely attached to your ceiling joists The fan is not clearing the room 1 Insufficient intake airfow within room 2 Insufficient CFM 1 Be sure a door or window is slightly ajar or opened...

Страница 11: ...el No Voltage V Frequency Hz Air Flow 0 1 SP CFM Power 0 1 SP W Max Current Amps Weight lb Note Light Spec 80RLED ADJ ITG80RLED VFB080B4RLED1 120 60 80 11 5 0 28 7 7 Single Speed 13W LED 1000 Lumens 2700K 4000K 5000K Note Design and specifications subject to change without notice Unit Inches mm ...

Страница 12: ...cidental consequential punitive or special damages arising out of or in connection with products use or performance regardless of the form of action whether in contract tort including negligence strict product liability or otherwise 4 This warranty does not extend to fluorescent lamp starters and tubes 5 The warranty does not cover if user does not comply with manufacturer s installation manual 6 ...

Отзывы: