Type BF Equipment. 

 

Date of Manufacturing (appears on device) 

 

Serial Number (appears on device)   

 

Dispose the device according to local rules for electronic waste.   

 

Authorized Representative:   
EMERGO EUROPE 
Prinsessegracht 20, 2514 AP The Hague 
The Netherlands 

 

FCC ID: W4P-SP-W02 (Trigno Base Station) 
FCC ID: W4P-SP-W06 (Trigno 

“Avanti” 

Sensor) 

IC: 8138A-DST03 (Model: Trigno Wireless Biofeedback System) 

 

 

This device complies with Part 15 of the FCC Rules and Industry Canad

a’s 

RSS-210 License Exempt Standards. Operation is subject to the following 
two conditions: (1) This device may not cause harmful interference. and (2) 
this device must accept any interference received, including interference 
that may cause undesired operation. 

This Class B digital apparatus complies with Canadian ICES-003. 

Cet appareil est conforme à des règlements d'Industrie Canada exempts de 
licence  standard  RSS  (s).  Son  fonctionnement  est  soumis  aux  deux 
conditions  suivantes:  (1)  Ce  dispositif  ne  doit  pas  causer  d'interférences 
nuisibles,  et  (2)  cet  appareil  doit  accepter  toute  interférence  reçue,  y 
compris  les  interférences  pouvant  entraîner  un  fonctionnement 
indésirable. 

Cet appareil numériqué de la classe B est conformé à la norme NMB-003 
du Canada 

This product complies with FCC OET Bulletin 65 radiation exposure limits 
set forth for an uncontrolled environment. 

To reduce potential radio interference to other users, the antenna type and 
its  gain  should  be  so  chosen  that  the  equivalent  isotropically  radiated 
power (EIRP) is not more than that required for successful communication. 

This equipment has been tested and found to comply with the limits for a 
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are 
designed to provide reasonable protection against harmful interference in 
a residential installation. This equipment generates, uses, and can radiate 
radio frequency energy and, if not installed and used in accordance with 
the instructions, may cause harmful interference to radio communications. 
There  is  no  guarantee  that  interference  will  not  occur  in  a  particular 
installation. If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the equipment 
off and on, the user is encouraged to try to correct the interference by one 
or  more  of  the  following  measures:  Reorient  or  relocate  the  receiving 

Содержание Trigno PM-W01

Страница 1: ...TrignoTM Wireless Biofeedback System...

Страница 2: ...User s Guide PM W01 Copyright 2017 by Delsys Incorporated MAN 031 0 1...

Страница 3: ...Software Installation 15 Powering the Base Station 15 Charging the Sensors 15 Turning the Sensor ON 16 Turning the Sensors OFF 17 Pairing the Sensors with the Base Station 17 Acquiring Data with the...

Страница 4: ...Maintenance and Care 25 Trigno Sensors 25 Trigno Base Station 25 Specifications 26 Appendix I 27 Mains Isolation 27...

Страница 5: ...ng signals by a qualified individual is required Rx ONLY Contraindications DO NOT USE on Patients with implanted electronic devices of any kind including cardiac pace makers or similar assistive devic...

Страница 6: ...e device use if a change in the device s performance is noted Contact Delsys technical support for assistance Delsys Inc guarantees the safety reliability and performance of the equipment only if asse...

Страница 7: ...nces pouvant entra ner un fonctionnement ind sirable Cet appareil num riqu de la classe B est conform la norme NMB 003 du Canada This product complies with FCC OET Bulletin 65 radiation exposure limit...

Страница 8: ...ursuant to FCC 15 21 of the FCC rules changes not expressly approved by Delsys Inc could void the User s authority to operate the equipment PC Requirements EMGworks 4 3 or later Windows 7 8 1 10 One U...

Страница 9: ...and digital integration through the Trigno SDK Software Development Kit and the Trigno API Application Program Interface Refer to the specific component senor User Guides for operational details of t...

Страница 10: ...eless communication scheme offers robust data transmission for up to 16 sensors with a nominal distance of 20m Under optimal environmental conditions no RF path obstructions or interfering sources thi...

Страница 11: ...ng Amber solid 10 Pairing Success Green rapid flash 6x 11 Pairing Fail Red double flash 3x 1 Power Off No LED arrow activity is present when the sensor is off 2 Charging Sensor Charging in the Trigno...

Страница 12: ...ments USB Communication The Base Station compiles data received from the active wireless sensors and transfers it over a USB 2 0 compliant connection to a Windows PC Analog Outputs The Base Station is...

Страница 13: ...power supply by connecting it to a Mains outlet or to an isolation transformer The power LED on the Base Station will illuminate anytime power is applied Trigno System are specifically designed and ap...

Страница 14: ...sage scenarios number of charge discharge cycles environmental temperature factors and cell manufacturing parameters which are subject to statistical variations Typical industry expectations assume an...

Страница 15: ...sors d Software Issued Command Sensors that are paired with the base station and are communicating with the host software application can be turned off by way of an off command sent from the software...

Страница 16: ...software Configuring the Trigno Sensors Once paired to the system EMG data and IMU data from sensor can be configured in the following ways Electromyographic EMG Sensing Ranges Input Range 11 mV or 2...

Страница 17: ...ite must be properly cleaned to remove dry dermis and any skin oils Wiping the skin prior to sensor application helps ensure a high quality signal If excessive hair is present it will also be necessar...

Страница 18: ...Sensor Interfaces are for single use only Immediately discontinue use if skin irritation or discomfort occurs All Adhesive Sensor Interfaces and Reference Electrodes are for single use only Discard af...

Страница 19: ...ctors Channels 1 16 EMG Signals The pinout of this connector replicates the pinout of the Bagnoli desktop EMG systems to facilitate connectivity between shared equipment for the Channels 1 16 This con...

Страница 20: ...22 Trigno System User s Guide Figure 5 Pinouts of the analog output connectors...

Страница 21: ...is field Firmware Version The current firmware version is shown in this field Serial Number Each Trigno Base Station has a unique serial number and identifier address which is shown in this field Netw...

Страница 22: ...only be changed if nearby sources are interfering with Trigno communications or the particular operating environment is causing significant path loss on the current frequency set Note that changing th...

Страница 23: ...sors in any liquid under any circumstance The sensors contain sensitive electronic circuitry Static discharges and intense magnetic fields should be avoided to prevent the risk of irreparable damage t...

Страница 24: ...scope Range 250 dps 500 dps 1000dps 2000dps Magnetometer Range 4900 uT Inter Sensor Delay 1 sample period Intra Channel Delay 1 sample period Analog Output Range 5 V Analog Output Bandwidth Ch 1 16 DC...

Страница 25: ...o have all patients electrically isolated from equipment within their reach and since the PC running the Trigno Software is conceivably within their reach it too must be isolated Delsys does not suppl...