DELSOL DSSB1D Скачать руководство пользователя страница 11

 

LOCATING THE SIDE BURNER 

– 

DELSOL

 

S

IDE BURNER

 

 

This gas appliance is designed and certified for outdoor use only.  Do not locate this  side 

burner  under overhead combustible surfaces.   Do not  operate the  side burner  inside a building, 
garage,  recreation  vehicle  or  any  enclosed  area.    When  choosing  an  area,  consider  exposure  to 
wind, proximity to traffic paths and length of gas supply line.  Keep gas supply lines as short as 
possible to reduce pressure drop.  Keep the side burner away from windy area but keep the side 
burner  in  a  well-ventilated  area.    Do  not  obstruct  the  flow  of  combustion  and  ventilation  air 
around the side burner.  The supporting edges  of the  side burner  must be located level  and flat.  
The counter should also be leveled. Ensure that the appliance remains at a distance of at least 12” 
from  any  combustible  material  such  as  wood,  gyprock,  paper  and  plants.  Do  not  store 
combustible materials, gasoline or flammable liquids or vapors around the appliance. 

 
 
 

 

 
 
 
CLEARANCE TO COMBUSTIBLE CONSTRUCTION  

A minimum clearance of 12” from the sides and 12” from the back of the side burner

 

to adjacent 

vertical combustible construction must be maintained.  

 
DÉGAGEMENT DE TOUTE CONSTRUCTION COMBUSTIBLE  
 

Il faut maintenir une distance minimum de 

12 po (30.48 cm)

 sur les côtés et de 

12 po (30.48 cm)

 

sur l’arrière du gril par rapport aux constructions combustibles verticales adjacentes. 

 

 
CLEARANCE TO NONCOMBUSTIBLE CONSTRUCTION  
A minimum clearance of 5 1/2” from the back of the side burner

 above cooking surface to 

non-combustible construction is required to allow the side burner hood to open completely.  

A  minimum  of  6”  clearance  to  the  sides

  of  the  side  burner  above  cooking  surface  to  non-

combustible construction is recommended. The side burner can be installed directly next to non-
combustible construction below the cooking surface. 
 

DÉGAGEMENT DE TOUTE CONSTRUCTION INCOMBUSTIBLE  

Une distance minimum de 5 1/2 po (13.97 cm) de l’arrière du gril au-dessus de toute surface de 
cuisson à la construction incombustible est prescrite pour permettre à la hotte d’ouvrir 
complètement. Une distance minimum de 6 po (15.24 cm) des côtés du gril au-dessus de la 
surface de cuisson à la construction incombustible est recommandée. Le gril peut être installé 
directement à proximité d’une construction incombustible en-dessous de la surface de cuisson.

 

 
 

 
 

 

NON-COMBUSTIBLE INSTALLATION ONLY 

Содержание DSSB1D

Страница 1: ...DELSOL SIDE BURNER INSTALLATION USE CARE MANUAL DSSB1D DSSB2 DSSB1F MODEL PN 18917B 10 15...

Страница 2: ..._________________________________________________ FOR YOUR RECORDS Please record the following information and refer to them when contacting the company or an authorized service agent This information...

Страница 3: ...ny other appliance A V E R T I S S E M E N T 1 Ne pas entreposer ni utiliser de l essence ni d autres vapeurs ou liquides inflammables dans le voisinage de l appareil ni de tout autre appareil 2 Une b...

Страница 4: ...e and other flammable vapors and liquids 7 DO NOT obstruct the flow of combustion and ventilation air to this appliance Keep the ventilation openings of the cylinder enclosure free and clear from debr...

Страница 5: ...is set for 11 water column and is for use with L P gas only The factory recommended regulator and hose must be used with a 20 lb L P cylinder L P GAS SAFETY REQUIREMENT The LP gas supply cylinder must...

Страница 6: ...One side of the enclosure shall be fully open or b For an enclosure having four sides a top and a bottom 1 At least two ventilation openings at cylinder valve level shall be provided in the sidewall e...

Страница 7: ...r place the cylinder onto the provided location 2 Check to ensure that the tank s gas valve on top of the cylinder is closed 3 Connect the 3 8 flare end of the hose to the grill coupling using a open...

Страница 8: ...e gas side burner is factory built for Natural Gas the regulator supplied is set for 4 water column The regulator is convertible to 10 water column for plumb in system LP application Do not use with a...

Страница 9: ...s used and installed with the arrow mark on the regulator pointing towards the side burner Do not use any replacement regulator other than that specified by DELSOL Use only pipe sealants that are appr...

Страница 10: ...ty before each use Only the factory supplied hose and regulator must be used Use only replacement regulator and hose assemblies specified by DELSOL LEAK TEST 1 Prepare a leak testing solution of sudsy...

Страница 11: ...rner to adjacent vertical combustible construction must be maintained D GAGEMENT DE TOUTE CONSTRUCTION COMBUSTIBLE Il faut maintenir une distance minimum de 12 po 30 48 cm sur les c t s et de 12 po 30...

Страница 12: ...CUT OUT DIMENSIONS DELSOL SIDE BURNER...

Страница 13: ...en lighting Refer to spiders and insects warning and procedure under the cleaning and maintenance page of this manual LIGHTING THE BURNERS 1 Make sure all knobs are in the OFF position 2 Turn on the g...

Страница 14: ...ess steel and get baked on These can be removed by using a mild abrasive pad like Scotch Brite with a stainless steel cleaner Use the mildest cleaner and always scrub in the direction of the grain Do...

Страница 15: ...EXPLODED VIEW DSSB1D...

Страница 16: ...13376 UPPER BURNER 1 7 S13377 LOWER BURNER 1 8 S16000 WIRE IGNITER 10 1 9 S12677 3 8 FLARE FIP 90 DEG ELBOW COUPLING 1 10 S12618 CLOSE NPT NIPPLE 1 11 S15351 REGULATOR NG LP 1 12 S12758 PIPE MANIFOLD...

Страница 17: ...EXPLODED VIEW DSSB2...

Страница 18: ...LATOR NG LP 1 8 S12618 CLOSE NPT NIPPLE 1 9 S12757 PIPE MANIFOLD SIDE BURNER DOUBLE 1 10 S23165Y FRONT PANEL 1 11 S13197 DELSOL KNOB 2 12 S13215 KNOB BEZEL 2 13 S13196 DELSOL LOGO 1 14 S15150 BURNER V...

Страница 19: ...EXPLODED VIEW DSSB1F...

Страница 20: ...6 S13215 KNOB BEZEL 1 7 S23174 MANIFOLD MOUNTING BRACKET 1 8 S12418 3 8 X 10 FLEX TUBING W BRASS FLARE NUTS 1 9 S12758 MANIFOLD PIPE SINGLE 1 10 S15150 BURNER VALVE W FLAME THROWER 1 11 S15351 REGULA...

Страница 21: ...es not apply to rust corrosion discoloration surface scratches weather and atmospheric related staining and oxidation which are normal conditions and to be expected with any outdoor products unless th...

Страница 22: ...hased to properly activate your warranty This information is for our internal use only Cut Here HOW TO OBTAIN SERVICE For service please contact your DELSOL dealer or call DELSOL direct at 800 789 220...

Страница 23: ...Customer Service ATTN Warranty Department 13259 East 166th Street Cerritos CA 90703 Fax no 562 802 3391 Place Postage Here Cut Here...

Отзывы: