![DèLonghi DEF9085DGW Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/delonghi/def9085dgw/def9085dgw_installation-and-service-instructions-manual_2469163016.webp)
16
TABLE FOR THE CHOICE OF THE INJECTORS
Natural gas
ULPG
Test Point Pressure [kPa]
1.0
9V?
BURNER
Injector
{ !
[mm]
Gas
Consumption
[MJ/h]
Injector
{ !
[mm]
Gas
Consumption
[MJ/h]
Auxiliary (A)
0.85
3.60
0.53
3.60
Semi-rapid (SR)
1.12
6.30
:V:
6.30
Rapid (R)
1.45
10.30
:BQ
10.80
Triple ring (TR)
1.60
Q9V:
:B?
QQB:
LUBRICATION OF THE GAS TAPS
If the gas tap becomes stiff, it is necessary to dismantle it carefully and clean it with petro-
leum spirit. Specialist high temperature resistant grease should be used to lubricate the tap
before replacing.
The operations must be carried out by an authorised person/service agent.