ELECTRICAL CONNECTION
A) If your appliance comes fitted with a plug, it will incor-
porate a 13 Amp fuse. If it does not fit your socket, the
plug should be cut off from the mains lead, and an ap-
propriate plug fitted, as below. WARNING: Very carefully
dispose of the cut off plug after removing the fuse: do
not insert in a 13 Amp socket elsewhere in the house as
this could cause a shock hazard. With alternative plugs
not incorporating a fuse, the circuit must be protected
by a 15 Amp fuse. If the plug is a moulded-on type, the
fuse cover must be re-fitted when changing the fuse
using a 13 Amp Asta approved fuse to BS 1362. In the
event of losing the fuse cover, the plug must NOT be
used until a replacement fuse cover can be obtained
from your nearest electrical dealer. The colour of the
correct replacement fuse cover is that as marked on the
base of the plug.
B) If your appliance is not fitted with a plug, please follow
the instructions provided below:
WARNING
- THIS APPLIANCE MUST BE EARTHED
IMPORTANT
The wires in the mains lead are coloured in accordance with
the following code:
Green and yellow:
Earth
Blue:
Neutral
Brown:
Live
As the colours of the wires in the mains lead may not cor-
respond with the coloured markings identifying the terminals
in your plug, proceed as follows:
The green and yellow wire must be connected to the termi-
nal in the plug marked with the letter E or the earth symbol
or coloured green or green and yellow. The blue wire
must be connected to the terminal marked with the letter N
or coloured black. The brown wire must be connected to the
terminal marked with the letter L or coloured red.