background image

See Rating

label

Type

Category

Execution

Max.input         Med.input           Low input  

Gas

Pressure

Two burner

models

Three burner

models

Kw

g/h

3.5

254

Kw

g/h

4.2

305

Kw

g/h

2.85

207

Kw

g/h

1.8

131

Kw

g/h

1.50

109

28-30 mbar

7 m

3

/h

8.4 m

3

/h

Gas

combustion air 

quantity

this appliance is designed  to operate with butane, at nominal pressure: 28÷30 mbar

GENERAL SAFETY INSTRUCTIONS

CYLINDER VALVE

If heater does not competely extinguish, including pilot, when gas is turned off at the regulator, do not remove regulator. Return valve
to open position and leave heater alight, which is perfectly safe, until attended to by the gas supplier.
Regulators, Hoses and clips
Check that tubing is completely over the nozzles at each end of the tubing and that is held firmly in place by tube clips. Examine
flexible tubing regularly and get your Dealer to fit new tubing 400 mm long if perished, worn or damaged.
L.P.G. ATTACKS NATURAL RUBBER-USE ONLY TUBING TO B.S. 3212 TYPE 2 SUPPLIED BY YOUR
DEALER.
Avoid bending or constricting the rubber tube when the pressure regulator is connected to the gas
cylinder.
A REGULATOR B.S. 3016 SET AT 28 MBAR (11.2 IN W.G.) for butane must de connected to the
appliance with the above tubing, using suitable tube clips.

VENTILATION

USE ONLY IN A WELL VENTILATED ROOM
Adequate ventilation must be provided in rooms in which the heater is used. This ensures removal of the products combustion and
allows the entry of replacement air.
Adequate ventilation should considerably reduce the possibility of condensation accurring.
The following table shows the smallest size of room suitable for each heat setting and the ventilation which must be provided.
The heater may be used for short periods in smaller rooms.

MAINTENANCE

Ensure that the heater is kept free of dust. When the heater is not in use it should be covered and stored in a dust-free place. Stains
on the exterior should be removed with soapy solution when the heater is cold. Dry with a polishing cloth. DO NOT use abrasive
cleaners which will damage the paint finishes.
Refer any mayor maintenance to your Local Authorised Dealer Major servicing should be carried out annually. If in doubt refer to your
authorised dealer.

SAFETY GUARD

The guard on this appliance conforms to the requirements of B.S. 1945: 1971 and  satisfies the heater appliance (fireguards)
regulations. The guard is to prevent risk of fire or injury from burns and no part of it should be permanently removed. It does not give
full protection for young children or the infirm.

87.5 cm

2

105 cm

2

18 m

3

MIN

MED

MAX

TWO BURNER MODELS

THREE BURNER MODELS

Room

Size

Room

Aperture

Room

Size

Room

Aperture

35 m

3

15 m

3

28.5 m

3

42 m

3

Heating Setting

4

Содержание RADIANT HEATER

Страница 1: ...afe place SPARE COPIES OF THIS LEAFLET CAN BE OBTAINED FROM YOUR DEALER U K AGENT De Longhi LTD 15 16 Bridle Close Stewarts Road Finedon Industrial Estate Wellingborough Tel 01933442040 manifactured by DE LONGHI Via L Seitz 47 TREVISO 31100 ITALY ...

Страница 2: ...Dealer DO NOT use the heater again until it has been inspected by your Dealer If the cylinder valve appears to be leaking when turned off refit the Black Branch Cap or Orange valve Cap 6 HEATER SAFETY INSTRUCTIONS KEEP IN A SAFE PLACE SPARE COPIES OF THIS LEALET CAN BE OBTAINED FROM YOUR DEALER This appliance MUST NOT be used in a basement high rise flats bathrooms or bedrooms and in rooms having ...

Страница 3: ...fore never attempt to mount or dismount it if the handle is not in this position Operation Once the Quick on is correctly mounted on the valve gas supply is possible by turning the regulator handle upwards counterclockwise To shut off the gas supply reverse above procedure an arrow engraved on the handle indicates the closing direction fig 3 Symbols engraved on the bonnet show how to operate the r...

Страница 4: ...N USE ONLY IN A WELL VENTILATED ROOM Adequate ventilation must be provided in rooms in which the heater is used This ensures removal of the products combustion and allows the entry of replacement air Adequate ventilation should considerably reduce the possibility of condensation accurring The following table shows the smallest size of room suitable for each heat setting and the ventilation which m...

Страница 5: ... rotate to position big flame TURNING OFF THE HEATER The heater will only be totally OFF when the supply of gas from the cylinder has been turned OFF at the valve After each use the appliance must be turned OFF at the valve DO NOT ATTEMPT to relight until FIVE minutes have elapsed WARNING FOR SWITCH ON SYSTEM When the heat is alight NEVER turn the switch on the cylinder to the disconnect position ...

Отзывы: