DeLonghi Pinguino T100ECO Скачать руководство пользователя страница 8

21

ENGLISH

Description of the control panel

THE CONTROL PANEL

A ON/OFF button
B  Mode selection button

Conditioning, BOOST (superconditioning), dehumidifying, fan.

C Air conditioning mode indicator light
D BOOST (superconditioning) mode indicator light
E

Dehumidifying mode indicator light

F

Fan mode indicator light (air purifying in model T100ECO)

G Increase temperature/humidity/  programmed operating time button
H Timer in operation indicator light
I

Display 

displays the temperature/humidity values set and the programmed operating

time

L

Timer button

M Temperature display
N Humidity display
O Reduce temperature/humidity/programmed operating time button
P/Q/R/S Fan speed and AUTO mode indicator lights
T

Fan speed selection button

U "SWING" button to move grille flaps (model T100ECO only)

NB: The "SWING" button (U) 

moves the grille flaps to distribute the cool air uniformly in the room.

When the button (

U

) is pressed and the flaps have  begun moving alternately forwards and

backwards, pressing the button again will lock the flaps in their current position.
Pressing the button again will restart the flaps moving forwards and backwards.
When the appliance is turned off, they will close irrespective of their position.

MODELS WITH REMOTE CONTROL UNIT (model T100ECO only)

Operation
-

Pressing the 

ON/OFF

button (

) turns the appliance on or off.

-

Pressing the 

FAN

button selects the required fan speed. Each time the 

FAN

button is pressed,

the speed of the fan rotates through the available options (Max, Min, Silent, Auto). On the
control panel, the LED corresponding to the selected speed lights up.

-

The 

SET

buttons (

+

) and (

-

) increase or reduce temperature or humidity.

The temperature or humidity set is displayed on the control panel.

Each time the button is pressed, the appliance confirms the selection with a beep and the light
on the remote control unit comes on.

NB: 

The remote control unit can be used for the following functions only: to turn the appliance

on or off, vary fan speed and set temperature or humidity depending on the operating mode
selected on the control panel. (see pages 22-23)

Replacing the batteries

Remove the cover on the back of the
remote control unit;

replace the flat batteries with two AAA 1.5
V batteries, making sure they are in the
correct position (see instructions inside the
battery compartment);

Replace the cover.

SET

+

-

FAN

FAN

button

SET +

button

SET -

button

ON/OFF

button

Indicator light

GB-5751012500  14-04-2004  15:59  Pagina 21

Содержание Pinguino T100ECO

Страница 1: ...ECO Istruzioni per l uso pag 4 User manual pag 17 Mode d emploi et d entretien pag 30 Betriebsanleitung pag 43 Gebruiksaanwijzing pag 56 Instrucciones de uso pag 69 Manual de instru es pag 82 95 IT 57...

Страница 2: ...sicher da Sie mit Ihrem Kauf zufrieden sein werden und das frische Wohlbefinden das Pinguino und SuperPin guino verbreiten ber eine lange Zeit genie en werden Wir bitten Sie sich etwas Zeit zu nehmen...

Страница 3: ...E COMANDOS ACCESSORI ACCESSORIES ACCESSOIRES ZUBEH R ACCESSOIRES ACCESORIOS ACESS RIOS A B C F E D P Q R S H L N O M I T U G Modello T100ECO illustrato Model T100ECO illustrated Mod le T100ECO illustr...

Страница 4: ...ppliance while the instructions aim to cover as many eventualities as possible caution and common sense should be used when operating and installing this air conditioning unit At the end of its workin...

Страница 5: ...emitted into the room In single unit models Pinguino a small part of this air is used to cool the refrigerant gas and then when hot and damp is discharged outside In models with case Super Pinguino th...

Страница 6: ...sure the air exhaust hose is unob structed Open the window or French window sligh tly and position the outlet as shown in figure B 13 13 12 A Preparing for use B C Keep air hoses as short and free of...

Страница 7: ...nge cap NOTE When installing the air conditioning unit semi permanently you should leave a door slightly open as little as 1 cm to guarantee correct ventilation 11 12 in the window pane in the wall yo...

Страница 8: ...s and backwards When the appliance is turned off they will close irrespective of their position MODELS WITH REMOTE CONTROL UNIT model T100ECO only Operation Pressing the ON OFF button turns the applia...

Страница 9: ...onditioning mode the indicator light M comes on To set operation of the appliance correctly press the G or O buttons until the required temperature is displayed The most suitable temperature for the r...

Страница 10: ...tted into the rapid coupling as shown in fig I NB in order for continuous drain to function make sure the accessory is connected correctly to the coupling To release press the coupling flange FAN MODE...

Страница 11: ...dby mode Press the timer button L The two centre segments flash on the display Use the G or O buttons to set the number of hours delay before the appliance comes on The indicator light H flashes until...

Страница 12: ...the for mation of ice The appliance start up again automatically when the defrosting process is completed P PF F PROBE FAILURE sensor damaged If this is displayed contact your service centre FULL TANK...

Страница 13: ...un by partially closing curtains and or blinds to make the appliance much more economical to run Never rest objects of any kind on the air conditioning unit Never obstruct the air intake or outlet gri...

Страница 14: ...The water should never be hotter than 40 C After washing leave the filter to dry To replace put the filters back in the intake grille then attach the intake grille to the appliance Never try and clean...

Страница 15: ...r conditioning unit works but does not cool the room window open there are heat sources in the room burner lamp etc the exhaust hose is detached air filters clogged the air conditioning unit is not po...

Страница 16: ...rating plate Max absorbed power during air conditioning Max absorbed power during dehumidifying Refrigerant Cooling capacity Dimensions internal unit width 495 mm height 940 mm depth 410 mm weight 34...