O p e r a t i o n

SWITCHING THE APPLIANCE ON

Connect the appliance to the mains supply.
On the display two lines will appear indicating Stand-by mode
Press the ON/OFF button (

A

) and then the MODE button until the

relevant function indicator appears viz.:

Indicator C 

: air-conditioning

Indicator D

: dehumidifying

Indicator E

: ventilation

AIR-CONDITIONING FUNCTION

This function is ideal in hot, humid weather conditions when the
atmosphere requires to be cooled and dehumidified.
To ensure proper function of the appliance, after selecting the air-
conditioning function, press b (

F

) or – (

G

) until the desired

temperature appears on the display.

The temperatures most suited to the atmosphere in summer vary
between (24-27°C) 75°-80°F. We do not advise selection of tem-
peratures much lower than those outside.

Select fan speed by pressing the “FAN” button (

Q

) until the fan

speed indicator appears:
MAX (

P

):  if you want the maximum power of the air-conditioner to

reach the desired temperature as quickly as possible.

MIN (

O

):  if you want to reduce the level of noise and still maintain

a good level of comfort.

SILENT (

N

):when minimum noise is required,

AUTO (

M

):if you prefer the appliance to select the fan speed for

the temperature selected on the display panel.

DEHUMIDIFYING FUNCTION

This function is ideal for reducing humidity in the atmosphere while
avoiding increases or decreases in temperature (in between sea-
sons, damp places, wet spells of weather).
When you select the dehumidifying function, the letters “     ” will
appear on the display.

The water is collected in the tank at the rear of the appliance.
When the tank is full, the appliance will stop working and the
display will show the letters “     ” (Full Tank); the tank must then be
emptied. When it is re-inserted, the appliance will re-start auto-
matically. N.B. remove the air exhaust hose (14).

In the air-conditioning function, the unit employs an exclusive con-
densation recycling system to dispose of excess moisture. In normal
conditions, condensation is disposed of automatically. When the
humidity is particularly high, an excess of condensation may built up
in the TANK 

. When this happens, the display  will  show the letters

“     “ (Full Tank); indicating that the TANK  should be emptied.  Whe-
never conditions of high humidity make the problem recurrent, you
may discharge the excess water directly into a drain, using the rub-
ber tube supplied. The tube should be inserted into the hole provi-
ded, after having removed the rubber stopper. (see figure).
Make sure the TANK  is put back correctly otherwise the display will
continue to show the letters “       ”

9

77

pac160 GB  25-01-2003  10:19  Pagina 11

Содержание Pinguino PAC 160

Страница 1: ...PA C 1 6 0 PA C 1 6 0 Use and maintenance manual pag 4 Mode d emploi et d entretien pag 19 Instrucciones de uso pag 34 Istruzioni per l uso pag 49 PAC160intro 25 01 2003 10 23 Pagina 1...

Страница 2: ...i et de le conserver soigneusement Ses conseils vous permettront d obtenir les meilleurs r sultats de votre Pinguino en toute s curit Gentile Cliente la ringraziamo per aver scelto un prodotto De Long...

Страница 3: ...escription Description Descriptci n Descrizione ACCESSORY SET ACCESSOIRES ACCESSOIRES ACCESSORI CONTROL PANEL PANNEAU DE COMMANDE TABLERO DE MANDOS PANNELLO COMANDI A C F L H G P B D E I M N Q O 11 19...

Страница 4: ...l injury Do not use outdoors Do not use the appliance in ways other than that for which it was intended Do not place the power cable under strain Avoid twisting and or tangling Ensure that the outlet...

Страница 5: ...transferred between different buildings The hot air in your room is passed through a coil cooled by refrigerant gas losing excess heat and moisture before being discharged again into the room In Ping...

Страница 6: ...ke grill 8 Rating plate 9 Water collection tank 10 Water drain tube 11 Stopper for drain tube 12 Power cord Description of the Accessories 13 Stopper and flange 14 Air exhaust hose 15 Air exhaust atta...

Страница 7: ...t the air exhaust hose 14 in its housing 5 at the rear of the appliance as shown in fig 1 If you have a double window use the suckers 16 supplied to keep the panes from opening wide figure 3 Fit the w...

Страница 8: ...the wing nut it s possible to use the window bracket also for sliding windows Position the hole of the bracket to allow a correct instal lation of the exhaust hose see the following instructions If y...

Страница 9: ...be closed off with the flange stop per 13 N B When operating the appliance with semi per manent installation it is advisable to leave a door slightly ajar even only 1cm to ensure free circulation of a...

Страница 10: ...failure in following normal safety procedures Replacement of the power cable must be carried out by qualified personnel THE DISPLAY A ON OFF Button B Function Button Air conditioning dehumidifying ven...

Страница 11: ...the temperature selected on the display panel DEHUMIDIFYING FUNCTION This function is ideal for reducing humidity in the atmosphere while avoiding increases or decreases in temperature in between sea...

Страница 12: ...onnect the appliance to the mains supply and press ON OFF button next select the required operating mode temperatu re fan speed etc Press the ON OFF button again the appliance will go into stand by mo...

Страница 13: ...sists call the service centre LOW TEMPERATURE If the machine is operating as an air conditioner or dehumidifier this will prevent the formation of ice The appliance will start up auto matically once t...

Страница 14: ...n s rays by drawing the curtains and or partially lowering the blinds so as to maximise energy savings Do not rest objects on the air conditioning unit Do not obstruct the air intake or outlet Make su...

Страница 15: ...ds fig 11 2 Remove the dust filter by detaching it from the external grill BEGIN OF SEASON CHECKS Check that the power cord and plug are undamaged and that the appliance is pro perly earthed The insta...

Страница 16: ...is set too high air filters are dirty the capacity of the air conditioner is not adequate for the conditions or the dimen sions of the room close the window eliminate source of heat set the thermostat...

Страница 17: ...ing capacity Number of fan speeds 2 silent Max air flow 460 m3 h Dimensions of internal unit width 452 mm 17 80 height 800 mm 315 depth 455 mm 179 1 weight 33 kg 72 8 lb Standard conditions Room tempe...

Страница 18: ...ed and all other obligations or liabilities on our part We do not authorize any other person or company to assume for us any liability in con nection with the sale or use of our AIR CONDITIONER This w...

Отзывы: