DeLonghi Pinguino F14 Скачать руководство пользователя страница 5

5

Important Safe-guards

• This appliance has been manufactured

to cool and de-humidify domestic envi-
ronments and should not be used for
other purposes.

• It is dangerous to alter or modify the

unit's characteristics in any way.

• The appliance must be installed in line

with the relevant national legislation.

Should repairs be necessary, contact
Parex Industries Ltd for your nearest autho-
rised De’ Longhi Service Agent. Unauthori-
sed servicing can be dangerous.

• This appliance is to be used by adults

only; keep away from children.

• Always ensure the appliance is earthed.

If you have any doubts check with a
qualified electrician.

• Avoid using extension leads with the

unit.

• Before cleaning or maintenance opera-

tions, always unplug the unit from the
socket.

• Do not pull on or place strain on the

power cable when moving the applian-
ce.

• The appliance should not be installed

where the atmosphere may contain
combustible gases, oil or sulphur, or near
heat sources.

• Do not rest hot or heavy objects onto

the appliance.

• Clean the  filters at least once a week.
• Avoid using heaters near the unit.
• If the unit cannot be transported in a

vertical position, anchor it to a sloping
surface. Avoid positioning it horizontally.

• Before transporting the unit drain the

condensation collecting-tray and tank.
After transportation, wait at least 1 hour
before switching on the unit.

• The packaging materials can be recy-

cled. You are therefore recommended
to place them in the special containers
for differentiated waste collection.

5751008700  15-04-2004  16:20  Pagina 5

Содержание Pinguino F14

Страница 1: ...F 1 4 F 1 4 Use and maintenance manual 5751008700 15 04 2004 16 20 Pagina 1...

Страница 2: ...he world we are con stantly improving the quality and performance of Pinguino We are confident that you will be satisfied with your purchase and enjoy the cool comfort created by the Pinguino for many...

Страница 3: ...1 2 3 4 5 6 7 9 15 16 18 19 17 20 8 10 11 12 14 Description CONTROL PANEL ACCESSORY SET 13 5751008700 15 04 2004 16 20 Pagina 3...

Страница 4: ...transferred between different buildings The hot air in your room is passed through a coil cooled by refrigerant gas removing excess heat and moisture before being discharged again into the room In si...

Страница 5: ...efore cleaning or maintenance opera tions always unplug the unit from the socket Do not pull on or place strain on the power cable when moving the applian ce The appliance should not be installed wher...

Страница 6: ...dow or door Open the window French window or door slightly and place the window attachment as shown in figure B 18 17 18 A Setting up B C For optimum results If you have a sash window place the bracke...

Страница 7: ...sions given in figure D 30 cm 30 cm MAX115 cm MIN 50 cm When the hose is not attached close the hole with the bung on the flange NOTE When the unit is installed semi permanently we recommend leaving a...

Страница 8: ...then be automatically maintained by the thermostat with considerable energy savings When regulating the thermostat the air conditioning function is temporarily inter rupted and the unit continues to...

Страница 9: ...ature will be exhausted from the accommodation tube on the back side of the appliance 3 1 9 6 TURN THE APPLIANCE OFF TO TURN THE UNIT OFF COMPLETELY SET THE FUNCTION SELECTOR TO THE POSI TION AND UNPL...

Страница 10: ...rotect the room from direct exposure to the sun s rays by drawing the curtains and or partially lowering the blinds so as to maximise energy savings Do not rest objects on the air conditioning unit Do...

Страница 11: ...ves To clean the filters 1 Remove the intake grills on either side of the appliance by rotating them outwards Fig F To remove dust deposited on the anti dust fil ter use a vacuum cleaner If very dirty...

Страница 12: ...come out of place the air filter is dirty the air conditioner has a capacity not ade quate for the conditions or the ldimensions of the room close the open window remove the heat source reinsert the...

Страница 13: ...city Number of fan speeds 2 Max air flow 360 m3 h Dimensions of internal unit width 452 mm height 800 mm depth 415 mm weight 33 5 kg Standard conditions ASHRAE 128 8 This appliance contains substances...

Страница 14: ...g h i S p A V i a L S e i t z 4 7 3 1 1 0 0 Tr e v i s o I t a l i a t e l 3 9 0 4 2 2 4 1 3 1 f a x 3 9 0 4 2 2 4 1 3 6 4 7 w w w d e l o n g h i c o m 5751008700 06 02 5751008700 15 04 2004 16 20 P...

Страница 15: ...15 ENGLISH 5751008700 15 04 2004 16 20 Pagina 15...

Отзывы: